background image

CONV Pelco To Bosch - firmware 0.01.xx 

Ewimar Sp. z o.o. 
www.ewimar.pl 

Made in Poland 

 

 

6.  Red LED: Command „DR-x”. 

Configuration for Red LED operation. 

DR-0

 – Indicates the translation and sending commands to 

Bosch cameras - only if the controlled camera address is configured in the converter.  

DR-1

 – Indicates wrong packets received on Port 1 - wrong protocol, incorrect transmission 

speed or transmission errors due to the use of poor quality cable.. 

 

  

 

7.  Supported camera addresses: Command „CAx-y”. 

The converter contains a camera table, the capacity of which depends on the license entered - by 
default 

16

 for the 

Standard

 version and 

1

 for the 

Lite

 version. The table should be assigned 

camera addresses in the range from 1-254, which will be supported by the converter. 
 
The 

x

 character mean the position number in the table, 

y

 mean supported camera address (1-

255) entered at that position. 
Choose the position number and assign an address to it. Example: To assign camera address 
128 to position No 1, enter: 

CA1-128

The order of the addresses in the table does not matter if the addresses repeat, only the first one 
matters. 

 

 

8.  Special: Command „Sxxxxxx”. 

Execution of a special command, for example entering the license code.. 

 

9.  Address shift: Command „CSx-y”. 

Described in the extended manual downloaded with the "

 Get user manual

 " button. 

Always active in 

Lite

 version, active in 

Standard

 version after purchasing the license. 

 

10. Advanced joystick correction: Command „CPx-y” i „CTx-y”. 

Described in the extended manual downloaded with the "

 Get user manual

 " button. 

Always active in 

Lite

 version, active in 

Standard

 version after purchasing the license. 

 

 

 

List of translated commands from the Pelco keyboard 

 

Controlling the camera using a Pelco keyboard directly depends on its functionality..

 

 

 

Nr 

Command from Pelco keyboard 

Bosch camera function 

Move Up / Down / Left / Right 

Move Up / Down / Left / Right 

Zoom in / Zoom out 

Zoom + / Zoom - 

Focus Far / Focus Near 

Focus Far / Focus Near  

Iris open / Close 

Iris Open / Close 

Auto Pan  

Scan 360

˚

 (AUX-1-ON) 

Auto Scan 

Auto scan with left / right limit (ON-2-ENTER) 

Left limit 

Set left limit for Auto Scan (SET-101-ENTER) 

Right limit 

Set right limit for Auto Scan (SET-102-ENTER) 

Learn Pattern ( Dowolny numer) 

Pattern A record (ON-100-ETER) 

10 

Stop Learn ( Dowolny numer)  

End record Pattern A (OFF-100-ENTER) 

11 

Run Pattern ( Dowolny numer) 

Continuous Playback Pattern A (ON-50-ENTER) 

12 

Call Preset 95 

Entry to menu (ON-46-ENTER) 

13 

Call preset 96 

Unlock advanced menu (OFF-90-ENTER) 

14 

Call preset 97 

Disable OSD (OFF-46-ENTER) 

15 

Call preset 101 

Show left limit (SHOT-101-ENTER) 

16 

Call Preset 102 

Show right limit (SHOT-102-ENTER) 

17 

Call preset 111 

Stop record pattern A (OFF-100-ENTER) 

18 

Call preset 112 

Stop record pattern B (OFF-101-ENTER) 

19 

Call preset 113 

Edit Tour 2 Custom (SHOT-900-ENTER) 

20 

Call preset 114 

Auto Pan/Scan 1 Speed (ON-14-ENTER) 

minus

 

21 

Call preset 115 

Tour Speed 1 (ON-15-ENTER) 

minus

 

22 

Call preset 116 

Scan left / light (ON-2-ENTER) 

23 

Call preset 120 

Continuous Playback Pattern A (ON-50-ENTER) 

24 

Call preset 121 

Single Playback Pattern A (ON-51-ENTER) 

25 

Call preset 122 

Continuous Playback Pattern B (ON-52-ENTER) 

Содержание CONV Pelco to Bosch

Страница 1: ...d version free for the Lite version 3 Advanced PAN TILT Joystick Curve Correction function individually for each camera optional license for the Standard version free for the Lite version 4 Simultaneo...

Страница 2: ...he correct packets have been received does not mean that they will be translated because it also depends on settings the supported addresses by the converter DIP SWITCHES Designed to switch on termina...

Страница 3: ...ta The right panel displays the command sent to the converter and its response about a changed setting or an error Each command must be entered in full syntax letters dashes etc and the allowable rang...

Страница 4: ...cribed in the extended manual downloaded with the Get user manual button Always active in Lite version active in Standard version after purchasing the license List of translated commands from the Pelc...

Страница 5: ...tern A ON 100 ETER 47 Set preset 112 Record pattern A ON 101 ETER 48 Set preset 113 Tour edit 1 ON 900 ETER 49 Set preset 114 Auto Pan Scan 1 ON 14 ENTER plus 50 Set preset 115 Tour Speed 1 ON 15 ENTE...

Страница 6: ...T PRESET 128 SET PRESET 1 SET PRESET 100 SEND AUX ON 997 SET PRESET 128 SET PRESET 9 SET PRESET 97 Example of remote FastAddress address change for camera G4 series Step Command Sequence from the Pelc...

Страница 7: ...continuously and cannot be stopped 1 Set the red LED to display erroneous packets 2 If the red LED blinks frequently transmission is interrupted as a result of incorrect connections or data collision...

Страница 8: ...ed for work within the EU and is compliant with essential requirements and other relevant provisions of EMC Directives 2014 30 EU and 2011 65 EU RoHS directive PN EN 61000 6 3 2008 A1 2012 Electromagn...

Отзывы: