31
6.0 In s ta llation an d fir st o p eration
Fig. 21
1. CAMT
2. U-Bracket
3. DIN908 M20x1.5 plug
4. Pivot bushing
5. Support plate
6. ISO4762 M10 screws
7. CPMT telescopic pillar outer profile
8. Spacer
9. Lock washer
Screws to use:
Support plate (thickness min 10 mm) attachment to
Ewellix pillar
• Screws: ISO4762, M10x16, class 8.8, Zn plated
• Tightening torque: 25 ±1.5 Nm
• Lock washer M10
• Thread locker: Loctite 243
U-Bracket attachment to support plate
• Plug: DIN908, M20x1.5, class 5.8, Zn plated
• Tightening torque: 50 ±2 Nm
• Thread locker: Loctite 243
6.5 Connection to the
control unit
All control units not approved by Ewellix for the CAMT linear
actuator are treated as third party controls. For further de-
tails regarding third party control units, please refer to the
guidelines in chapter 4 Structure and function
(⮑ page 16).
CAUTION
The use of a third-party control unit may lead to material
damage. If a third-party control unit is used, the manufacturer
does not assume any liability for damage that may caused.
Therefore:
• It is recommended that an Ewellix control unit be used
• When using a third-party control unit, the requirements stipulated
for the third-party control unit must be adhered to chapter 4.5
Requirements for third-party control units (mandatory in
medical applications) (⮑ page 24).
NOTE
A low-voltage plug connects the device to an external control
unit. Follow the Ewellix control unit's operating manual
instructions during the connection process.
Depending on the selected option, the CAMT can be deliv-
ered with or without cable.
When a cable is selected, the actuator side of the cable is
mandatorily equipped with the matching Molex mini fit con-
nector as can be found on the CAMT actuator.
The other side on the other hand, can either be delivered
with a DIN-8 connector when used in combination with a
Ewellix control unit or flying leads to adapt to a custom con-
trol unit.
6.5.1 Connecting DIN-8 plug to Ewellix
control unit
The insertion position is given by the geometric shape of the
plug. Strain relief for this system is provided via attached
components of the respective Ewellix control unit casing.
1. Check the sealing ring of the DIN-8 plug (⮑ fig. 22) and
the plug, for any damage.
Fig. 22
Sealing ring
NOTE
Damaged sealing rings and twisted plugs can no longer
guarantee protection pursuant to IP40. They must be replaced by
the manufacturer (refer to chapter ⮑ 5.2 Transport inspection,
page 28)
2. Lightly apply lubricant, Klübersynth VR 69-252 (part no.
0118037), to sealing ring (⮑ fig. 22).
3
8
4
7
5
6
2
1
9
Содержание CAMT20
Страница 1: ...CATEGORY MAX 2 LINES INSTALLATION OPERATION AND MAINTENANCE MANUAL CAMT20 Linear actuator...
Страница 2: ......