background image

INSTALLATION

Mount the EWT-3611 Thermostat about 5 feet above the 
floor in an area with good air circulation at average 
temperature. DO NOT install the thermostat where it can 
be affected by:

drafts or dead spots behind doors and in   corners
hot or cold air from ducts
radiant heat from sun or appliances
concealed pipes and chimneys
on surfaces such as an outside wall, that  are a              

different temperature then the room air 
temperature. 

EWC Controls Inc.   385 Highway 33   Englishtown, NJ 07726   800-446-3110   FAX 732-446-5362     E-Mail- [email protected]

2

CAUTION

!

To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

Copyright © 2009 EWC Controls All Rights Reserved

®

HE

AT

TE

MP

SE

T

F

CO

OL

SP

AN

FIL

TE

R

Mount wallplate and Thermostat

Remove the wallplate from your thermostat by pressing the 
release tab on the bottom of the thermostat. See Figure 2.

Figure 2

Position wallplate on the wall and pull the wires through the 
large opening. Level the unit for appearance. Mark the 
mounting holes for the provided wall anchors.
Drill holes with a 3/16” bit and gently tap anchors into holes 
until flush with the wall.
Reposition wallplate to wall, pulling wires through the large 
opening. Insert mounting screws provided into the wall 
anchors and tighten. See figure 3. 

Y

R

G

RC/O RH/B

C

W

Figure 3

In order for this thermostat to control your system, the system type 
must be specified by the selector switch on the circuit board inside  
the thermostat. There is also a selector switch for your choice of 
Fahrenheit or Celsius display. See figure 4.

Fan Mode Selector (HG-HE switch)

The factory position is in the “HG” position. Leave it in this position if 
you have a gas furnace or an oil burner. If you have an electric 
furnace or hot water coil change the position to “HE”. 

System Selector (STANDARD - HEAT PUMP switch)

The factory position for this switch is in the STD position. Leave it in 
this position if you have ANY system that uses gas, oil, electric or hot 
water heating.
If you have a single stage Heat Pump, the thermostat can be 
configured to the Heat Pump mode by moving the switch to the “HP” 
position. This thermostat model 

does not

 have auxiliary or 

emergency heat features, therefore it cannot be used on heat pump 
systems that require these functions.

Changing the battery:

One fresh AA alkaline battery should provide about one year of 
service. However, when the battery becomes drained, the thermostat 
will not function. At your earliest convenience, you need to replace 
the battery with one new AA alkaline battery.
NOTE: If you remove or replace the battery, the temperature set point 
and Span settings will reset back to the factory default settings. 
NOTE: If you plan to be away from the premises over 30 days, we 
recommend that you replace the old battery with a new alkaline 
battery prior to leaving. 

Span Setting

Your thermostat is set at the factory to cycle at 2°F (1°C) above and 
below the set temperature. (Span = 2) This setting has been 
designed to provide a comfortable room temperature under most 
conditions.  However, if you find your system cycling too fast or too 
slow, the Span can be adjusted to modify the cycle time.
Press and hold BOTH            and            keys for three seconds.
SPAN will be displayed on the LCD.
Press              to raise the Span to 3. This setting increases cycle 
time by allowing your system to run longer cycles.
Press              to lower the Span to 1. This setting decreases the 
cycle time by causing your system to run shorter cycles.
The Span settings remain the same for both HEAT and COOL, and 
can be changed in any System Switch position. Any loss of 24vac 
and/or battery power will default the Span back to the factory default 
setting of 2.

O

N

D

P

1

2

3

4

H

P

S

T

D

H

E

H

G

Figure 4

FAHRENHEIT 

Jumper

The installer should be an experienced and trained 
HVAC contractor. Failure to read and follow 
instructions carefully before installation or 
operation could damage this control or cause 
property damage. Test the finished installation for 
proper operation.

Содержание EWT-3611

Страница 1: ...Hz 1 0 Amp Max load per terminal Thermal Ratings Set point Temperature Range 45 F to 95 F Operating Ambient Temperature 30 F to 99 F Storage Temperature Range 14 F to 140 F ATTENTION This product does not contain mercury However this product may replace a unit which contains mercury EWC Controls Inc would like to advise all technicians and consumers that all mercury thermostats should be recycled ...

Страница 2: ...r this switch is in the STD position Leave it in this position if you have ANY system that uses gas oil electric or hot water heating If you have a single stage Heat Pump the thermostat can be configured to the Heat Pump mode by moving the switch to the HP position This thermostat model does not have auxiliary or emergency heat features therefore it cannot be used on heat pump systems that require...

Страница 3: ...C GAS FURNACE C T T TO BOILER OR CIRCULATOR CONTROL EWC Controls Inc 385 Highway 33 Englishtown NJ 07726 800 446 3110 FAX 732 446 5362 E Mail info ewccontrols com 3 Copyright 2009 EWC Controls All Rights Reserved ISOLATION CIRCUIT REQUIRED NO ISOLATION CIRCUIT REQUIRED Jumper NON ZONED HEAT PUMP C RH B Y G R W RC O EWT 3611 R W G C 1 HEAT 1 COOL HEAT PUMP Y Figure 5 Figure 6 Figure 7 Figure 8 Figu...

Страница 4: ...in COOL Setting New Set Point Temperature Press either or once and display the set point temperature Press either or again to change your desired set point temperature Hold the key down for over 2 seconds to fast advance the set point temperature Auto Shut Off Your thermostat will automatically shut off in HEAT mode if the room temperature rises above 95 F 35 C It will shut off in COOL mode if the...

Отзывы: