USE WITH SOLENOID LOCK DSIEC-EL
For use with solenoid lock (DUOSIDA DSIEC-EL or similar) the
charge controller outputs are configured as follows:
B – Signal. If the solenoid is 12V is expected, if it is
unlocked 0V is expected.
R and W – Locking of solenoid is powered through these outputs
for locking and unlocking. Locking is done with 300ms pulse. If it is
detected that the solenoid has not function, the locking/unlocking
action is repeated after 5 seconds. If the locking action is reverse,
the wires should be swapped between R and W connections.
Connection of DSIEC-EL solenoid:
L
N
CONT
Y
G
R
PE
B
R
W
PE
CP
PP
IC
PE
W
R
B
Blue
Yellow
Red
White
S
R=
R=0
There can be different colour wires used for DSIEC-EL solenoids,
therefore it is advised to consult the datasheet of the
manufacturer. The connections can also be determined using a
multimeter.