Possible Actions
•
Pressing
S
changes the presentation of the SDTI network, and shows alternately a
representation based on the serial number, or on the topology.
•
Pressing
ENTER
resets the status information.
•
Pressing
SPACEBAR
to pause or restart the monitoring
•
Pressing
F5
to refresh the SDTI network schema
•
Pressing
RIGHT ARROW
to display the second SDTI network monitoring window.
From this window, you can also disconnect the Xhub branch on which the EVS server is
located from the network. See section "Disconnecting a Machine from the XNet Network"
on page 182 for more information.
4.2.3.
Hardware Error Counters
The second page of the SDTI monitoring section provides a list of the hardware devices
present on the SDTI network, sorted by serial number, with error counters information.
In operating conditions, when all machines are connected, the
CpLk
(electrical quality of
the network) and
Frm
(checksum on the packets) counters should not increase at all.
At the contrary, the counters will increase during disconnection/connection of/to the
network.
4.2.4.
Disconnecting a Machine from the XNet
Network
Introduction
From the Monitoring section, page 2, you can disconnect from the XNet network the XHub
branch the EVS server your are working on is connected to. This can be useful when
setting up an SDTI network or troubleshooting an SDTI network issue.
182
4. Monitoring
EVS Broadcast Equipment SA
Issue 12.02.C - April 2014
Содержание XSnano
Страница 1: ...CONFIGURATION MANUAL Version 12 02 April 2014 ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 57: ...CONFIGURATION MANUAL XSnano Server 12 02 3 Multicam Configuration 47 ...
Страница 70: ...Rear panels before 2013 60 3 Multicam Configuration EVS Broadcast Equipment SA Issue 12 02 C April 2014 ...
Страница 194: ......
Страница 197: ......