EVS Broadcast Equipment SA
39
Port1/2-Wavelength
Indicates the current wave length of the corresponding output port on the
SFP output module A between 0nm and 2000nm. When there is a non
fiber SFP or RX module installed, this value will be 0.
SFP2-Vendor
These status item display the name of the vendor of the SFP input/output
module B.
SFP2-Type
These status items display the type name/number of SFP input/output
module B.
SFP2-Temp-Stat
These indicate whether the above indicated temperature of SFP
input/output module B is
Too_High
,
High
,
OK
,
Low
or
Too_Low
.
This can also be
NA
in case Temperature monitoring is not available or
the module is not inserted.
SFP2-Volt-Stat
These indicate whether the above indicated voltage usage of SFP
input/output module B is
Too_High
,
High
,
OK
,
Low
or
Too_Low
.
This can also be
NA
in case Voltage monitoring is not available or the
module is not inserted.
Port3/4-Enabled
These item indicate whether the corresponding output on SFP output
module is
enabled
,
disabled
or
NA
(Not available, when no input
signal is available or an input module is inserted)
Port3/4-Power
These status items indicate the current transmitter power of the specified
port on SFP output module B between 0mW and 6.55mW. When an
input module is inserted or no SFP module is inserted this value is 0.
Port3/4-Power-Stat
These indicate whether the output power of the specified port on SFP
output module B is
Too_High
,
High
,
OK
,
Low
or
Too_Low
. Can
also be
NA
in case of an input module or no module is inserted.
Port3/4-Bias
These status items indicate the current laser bias of the specified port on
SFP output module B is between 0mA and 300mA. When there is a non
fiber SFP or RX SFP installed, this value will be 0.
Port3/4-Bias-Stat
These indicate whether the laser bias of the specified port on SFP output
module B is
Too_High
,
High
,
OK
,
Low
or
Too_Low
. This can also
be
NA
in case laser bias monitoring is not available or no module is
inserted.
Port3/4-Wavelength
Indicates the current wave length of the corresponding output port on
SFP output module B between 0nm and 2000nm. When there is a non
fiber SFP or RX module installed, this value will be 0.