NOTICE

 

Improper treatment or misuse of generator can cause 
permanent damage.

 

• 

 

NEVER modify generator in any way.

 

• 

 

NEVER tamper with governed speed. Generator 

supplies correct rated frequency and voltage when 
running at governed speed.

 

• 

 

Damage to generator caused by misuse or 

modi  cation is not covered under Warranty.

 

 

Safety Messages

 

 

 

Electric Shock Hazards

 

Medical and Life Support Uses

 

 

WARNING

 

Generators produce powerful voltage that can cause 
death or great physical harm.

 

 

NEVER touch bare wires or receptacles.

 

 

NEVER use generator with elect rical cords that are 
worn, frayed, bare, or otherwise damaged.

 

 

NEVER operate generator in rain or snow, or when 
the generator is set on wet surface.

 

 

Keep the generator out of reach of children, pets, 
and untrained people.

 

Fire and Burn Hazards

 

WARNING

 

 

WARNING

 

 

In case of emergency, call 999 immediately.

 

 

NEVER use this product to power life support 
devices or life support appliances.

 

 

NEVER use this product to power medical devices 
or medical appliances.

 

 

Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live.

 

 

Inform your electrical provider immediately if a loss 
of power would cause you or anyone in your 
household to experience a medical emergency.

 

Generator Damage Hazards

 

 

Fuel and its vapours are extremely   ammable and 
explosive under certain conditions.

 

 

 

 

Refuel generator only outdoors, in a well-ventilated 
area.

 

 

NEVER enclose the generator in any structure.

 

 

Keep generator at least 2 meters (6 feet) away from 
buildings, other equipment, and combustible 
materials during operation.

 

 

NEVER 

fuel tank while the engine is running. 

Turn generator OFF and allow to cool before 
with fuel.

 

 

NEVER smoke or allow   ames or sparks near the 
generator or where gasoline is stored.

 

 

NEVER ov 

the      fuel tank (there should be 

no fuel in the  neck). After refueling, make sure the 
tank cap is closed properly and securely.

 

 

Be careful not to spill fuel when refueling. Spilled 
fuel or fuel vapour may ignite. If any fuel is spilled, 
be sure the area is dry before starting the engine.

 

 

Avoid repeated or prolonged contact with skin or 
breathing of vapour.

 

 

WARNING

 

 

The exhaust becomes very hot during operation and 

remains hot for a while after stopping the engine.

 

 

NEVER touch hot surfaces and avoid hot gases.

 

 

Let the engine cool before storing the generator 
indoors.

 

2

 

www.evopower.co.uk

 

EVO1000i / EVO2000i / EVO2000Ei / EVO3000i / EVO3000Ei Inverter Generator Owner’s Manual

 

 

Содержание EVO1000i

Страница 1: ...Inverter Generator Owner s Manual EVO1000i EVO2000i EVO2000Ei EVO3000i EVO3000Ei For product enquiries or support please visit www evopower co uk or call 01646 66 38 48 for more information...

Страница 2: ...ation about your generator You may be asked to provide this information should you require product service or support tion information spe to your generator model number and serial number can be found...

Страница 3: ...ng for Operation 10 Starting Generator 11 AC Operation 13 Stopping Generator 13 Low Oil Protection 13 High Altitude Operation 13 Powering Appliances 14 MAINTENANCE 16 Maintenance Schedule 16 Engine Oi...

Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK ii www evopower co uk EVO1000i EVO2000i EVO2000Ei EVO3000i EVO3000Ei Inverter Generator Owner s Manual...

Страница 5: ...messages are introduced by a signal word Explosion Toxic fumes Fire indicating the hazard level Indicates an imminently hazardous Chemical burn Electrical shock Hot surface DANGER WARNING situation wh...

Страница 6: ...ur electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency Generator Damage Hazards Fuel and its vapours are extremely ammable...

Страница 7: ...H FIGURE 2 EVO2000i EVO2000Ei EVO3000i EVO3000Ei Model Label Locations PRODUCT LABEL A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a po...

Страница 8: ...READY LIGHT ON 7 PULL RECOIL TO START 8 MOVE CHOKE TO OFF 7 PULL RECOIL TO START 8 MOVE CHOKE TO OFF IF TANK LOW OR RUN TO EMPTY PRIME 30TO 50X STOPPING INSTRUCTIONS STOPPING INSTRUCTIONS 1 UNPLUG PO...

Страница 9: ...ing items are included in the generator package Inverter Generator Owner s Manual Oil Fill Container Oil Drain Pipe Spark Plug Wrench Screwdriver Handle Screwdriver Universal Bit Inspect for Damage Ca...

Страница 10: ...enerator be connected to an earth ground Before using the generator connect a copper wire minimum 14 AWG from the ground terminal see Figure 4 to an earth ground Consult a licensed electrician for pro...

Страница 11: ...page 11 for instructions on operating generator Generator is heavy Obtain assistance to lift the generator to avoid back or other bodily injury Accessories Oil Drain Pipe Oil Fill Container Screwdriv...

Страница 12: ...circuits from damage caused by overload or short circuit by stopping low of electricity from generator to the DC appliance If there is no power at DC outlet see Troubleshooting on page 27 4 Overload...

Страница 13: ...temperatures that can cause serious burns if touched NEVER touch hot surfaces D Case Feet Provides stability to the generator E Recoil Starter Handle Starts engine F Back Maintenance Cover G Fuel Cap...

Страница 14: ...surface and avoid loose sand or snow If generator is tilted or overturned fuel spillage may result Also if generator is overturned or sinks into a soft surface sand dirt or water may enter generator W...

Страница 15: ...d all information provided in this Owner s Manual 5 FIGURE 7 iency Mode Switch 6 Turn the fuel valve to the ON position OFF FUEL 1 Fill the fuel tank and check oil is to appropriate level NOTE The gen...

Страница 16: ...NOTICE If the engine stops and will not restart check the engine oil level before troubleshooting in other areas 9 While securing the generator with one hand grip the recoil starter handle and pull sl...

Страница 17: ...al use 1 Turn OFF any connected appliances and unplug any connected power cords 2 Allow the generator to run for 2 3 minutes 3 Press the engine control switch to the STOP position 4 Turn the fuel valv...

Страница 18: ...for any purpose other than its intended use Do not parallel connect generators or lengthen the exhaust pipe Do not connect generator to any household circuit otherwise it may destroy generator or home...

Страница 19: ...THIS PAGE INTENTIONALLY LEFT BLANK EVO1000Si EVO2000Si EVO2000SEi EVO3000Si EVO3000SEi Inverter Generator Owner s Manual www evopower co uk 15...

Страница 20: ...of the emission control devices and systems may be performed by any non road engine repair establishment or individual NOTICE The maintenance schedule applies to normal operating conditions If you ope...

Страница 21: ...recommended for general all temperature use FIGURE 18 Oil Fill Cap Removal 15W 40 5 Check the oil level is up to the innermost thread of the crankcase FIGURE 17 Recommended Oil Viscosity Checking Eng...

Страница 22: ...l cause the low oil protection feature to shut off the generator to prevent engine damage 1 surface EVO2000i model illustrated CAUTION 9 the choke and attach the back maintenance cover FIGURE 21 Oil F...

Страница 23: ...e of new unused oil See Figure 17 for recommended oil type EVO1000i EVO2000i Oil Capacity ml 250 450 TABLE 5 Engine Oil Capacity FIGURE 23 Oil Drain Pan 13 FILL 7 FIGURE 26 Adding Engine Oil 14 Check...

Страница 24: ...f any fuel is spilled be sure the area is dry before starting engine Avoid repeated or prolonged contact with skin or breathing vapor Avoid body contact with any fuels oil and lubricants used in the g...

Страница 25: ...cap A and fuel strainer B A B 4 Slowly pour petrol into the fuel tank Be careful not to FIGURE 30 Fuel Level 5 Reinstall the fuel cap and fully tighten FIGURE 31 Fuel Strainer Removal 4 Clean the fuel...

Страница 26: ...the air ter C FIGURE 33 Air Filter Removal EVO2000i Models Screwdriver handle Screwdriver universal bit Household soap and water Clean dry cloth Clean engine oil 1 Stop the generator if the engine is...

Страница 27: ...ent or prolonged contact with engine oil may cause skin cancer Thoroughly wash hands and any areas of skin exposed to used oil with soap and water NOTE The engine will smoke during initial start up if...

Страница 28: ...f insulator is cracked or chipped use a new spark plug If the spark plug is in good condition clean spark plug with wire brush 8 Measure spark plug gap with spark plug gauge Gap should be 0 024 0 028...

Страница 29: ...he spark plug hole and pull the recoil starter handle slowly to turn engine and distribute the oil Reinstall the spark plug At this point the piston is coming up on its compression stroke and both int...

Страница 30: ...buretor Pump fuel in the carburetor EVO2000i models only Dirtyair flter Clean or replace air flter Dirty spark arrestor screen Clean spark arrestor screen Engine suddenly stops No fuel Add fuel No or...

Страница 31: ...T F Fuel 6 draining26 22 9 9 valve G Troubleshooting 27 U 5 W 15 Generator location 11 5 operation 11 3 starting 12 stopping 14 storing 26 transporting 26 5 Ground 6 6 terminal 8 H 14 M Maintenance 17...

Страница 32: ...GENPOWER LTD Unit 1 Dowty Park Thornton Ind Est Milford Haven UNITED KINGDOM SA73 2RS T 44 0 1646 663 848 F 44 0 1646 663 856 e sales evopower co uk www evopower co uk...