background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Inverter Generator

 

Owner’s Manual

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

EVO1000i 
EVO2000i 

EVO2000Ei 

EVO3000i 

EVO3000Ei

 

 

For product enquiries or support, please visit www.evopower.co.uk or 

call 01646 66 38 48 for more information.

 

Содержание EVO1000i

Страница 1: ...Inverter Generator Owner s Manual EVO1000i EVO2000i EVO2000Ei EVO3000i EVO3000Ei For product enquiries or support please visit www evopower co uk or call 01646 66 38 48 for more information...

Страница 2: ...ation about your generator You may be asked to provide this information should you require product service or support tion information spe to your generator model number and serial number can be found...

Страница 3: ...ng for Operation 10 Starting Generator 11 AC Operation 13 Stopping Generator 13 Low Oil Protection 13 High Altitude Operation 13 Powering Appliances 14 MAINTENANCE 16 Maintenance Schedule 16 Engine Oi...

Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK ii www evopower co uk EVO1000i EVO2000i EVO2000Ei EVO3000i EVO3000Ei Inverter Generator Owner s Manual...

Страница 5: ...messages are introduced by a signal word Explosion Toxic fumes Fire indicating the hazard level Indicates an imminently hazardous Chemical burn Electrical shock Hot surface DANGER WARNING situation wh...

Страница 6: ...ur electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency Generator Damage Hazards Fuel and its vapours are extremely ammable...

Страница 7: ...H FIGURE 2 EVO2000i EVO2000Ei EVO3000i EVO3000Ei Model Label Locations PRODUCT LABEL A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a po...

Страница 8: ...READY LIGHT ON 7 PULL RECOIL TO START 8 MOVE CHOKE TO OFF 7 PULL RECOIL TO START 8 MOVE CHOKE TO OFF IF TANK LOW OR RUN TO EMPTY PRIME 30TO 50X STOPPING INSTRUCTIONS STOPPING INSTRUCTIONS 1 UNPLUG PO...

Страница 9: ...ing items are included in the generator package Inverter Generator Owner s Manual Oil Fill Container Oil Drain Pipe Spark Plug Wrench Screwdriver Handle Screwdriver Universal Bit Inspect for Damage Ca...

Страница 10: ...enerator be connected to an earth ground Before using the generator connect a copper wire minimum 14 AWG from the ground terminal see Figure 4 to an earth ground Consult a licensed electrician for pro...

Страница 11: ...page 11 for instructions on operating generator Generator is heavy Obtain assistance to lift the generator to avoid back or other bodily injury Accessories Oil Drain Pipe Oil Fill Container Screwdriv...

Страница 12: ...circuits from damage caused by overload or short circuit by stopping low of electricity from generator to the DC appliance If there is no power at DC outlet see Troubleshooting on page 27 4 Overload...

Страница 13: ...temperatures that can cause serious burns if touched NEVER touch hot surfaces D Case Feet Provides stability to the generator E Recoil Starter Handle Starts engine F Back Maintenance Cover G Fuel Cap...

Страница 14: ...surface and avoid loose sand or snow If generator is tilted or overturned fuel spillage may result Also if generator is overturned or sinks into a soft surface sand dirt or water may enter generator W...

Страница 15: ...d all information provided in this Owner s Manual 5 FIGURE 7 iency Mode Switch 6 Turn the fuel valve to the ON position OFF FUEL 1 Fill the fuel tank and check oil is to appropriate level NOTE The gen...

Страница 16: ...NOTICE If the engine stops and will not restart check the engine oil level before troubleshooting in other areas 9 While securing the generator with one hand grip the recoil starter handle and pull sl...

Страница 17: ...al use 1 Turn OFF any connected appliances and unplug any connected power cords 2 Allow the generator to run for 2 3 minutes 3 Press the engine control switch to the STOP position 4 Turn the fuel valv...

Страница 18: ...for any purpose other than its intended use Do not parallel connect generators or lengthen the exhaust pipe Do not connect generator to any household circuit otherwise it may destroy generator or home...

Страница 19: ...THIS PAGE INTENTIONALLY LEFT BLANK EVO1000Si EVO2000Si EVO2000SEi EVO3000Si EVO3000SEi Inverter Generator Owner s Manual www evopower co uk 15...

Страница 20: ...of the emission control devices and systems may be performed by any non road engine repair establishment or individual NOTICE The maintenance schedule applies to normal operating conditions If you ope...

Страница 21: ...recommended for general all temperature use FIGURE 18 Oil Fill Cap Removal 15W 40 5 Check the oil level is up to the innermost thread of the crankcase FIGURE 17 Recommended Oil Viscosity Checking Eng...

Страница 22: ...l cause the low oil protection feature to shut off the generator to prevent engine damage 1 surface EVO2000i model illustrated CAUTION 9 the choke and attach the back maintenance cover FIGURE 21 Oil F...

Страница 23: ...e of new unused oil See Figure 17 for recommended oil type EVO1000i EVO2000i Oil Capacity ml 250 450 TABLE 5 Engine Oil Capacity FIGURE 23 Oil Drain Pan 13 FILL 7 FIGURE 26 Adding Engine Oil 14 Check...

Страница 24: ...f any fuel is spilled be sure the area is dry before starting engine Avoid repeated or prolonged contact with skin or breathing vapor Avoid body contact with any fuels oil and lubricants used in the g...

Страница 25: ...cap A and fuel strainer B A B 4 Slowly pour petrol into the fuel tank Be careful not to FIGURE 30 Fuel Level 5 Reinstall the fuel cap and fully tighten FIGURE 31 Fuel Strainer Removal 4 Clean the fuel...

Страница 26: ...the air ter C FIGURE 33 Air Filter Removal EVO2000i Models Screwdriver handle Screwdriver universal bit Household soap and water Clean dry cloth Clean engine oil 1 Stop the generator if the engine is...

Страница 27: ...ent or prolonged contact with engine oil may cause skin cancer Thoroughly wash hands and any areas of skin exposed to used oil with soap and water NOTE The engine will smoke during initial start up if...

Страница 28: ...f insulator is cracked or chipped use a new spark plug If the spark plug is in good condition clean spark plug with wire brush 8 Measure spark plug gap with spark plug gauge Gap should be 0 024 0 028...

Страница 29: ...he spark plug hole and pull the recoil starter handle slowly to turn engine and distribute the oil Reinstall the spark plug At this point the piston is coming up on its compression stroke and both int...

Страница 30: ...buretor Pump fuel in the carburetor EVO2000i models only Dirtyair flter Clean or replace air flter Dirty spark arrestor screen Clean spark arrestor screen Engine suddenly stops No fuel Add fuel No or...

Страница 31: ...T F Fuel 6 draining26 22 9 9 valve G Troubleshooting 27 U 5 W 15 Generator location 11 5 operation 11 3 starting 12 stopping 14 storing 26 transporting 26 5 Ground 6 6 terminal 8 H 14 M Maintenance 17...

Страница 32: ...GENPOWER LTD Unit 1 Dowty Park Thornton Ind Est Milford Haven UNITED KINGDOM SA73 2RS T 44 0 1646 663 848 F 44 0 1646 663 856 e sales evopower co uk www evopower co uk...

Отзывы: