background image

7

EVONIC - 104 INSTRUCTION MANUAL TEMPLATE ISS. 1

EVONIC - 104 INSTRUCTION MANUAL TEMPLATE ISS. 1

ELECTRA ISS. 1

ELECTRA ISS. 1

 MODEL DIMENSIONS

The model shown in these drawings is an Electra 1250, however the same processes apply 
to all Evoflame and E-Smart models. Scan the QR code for more detailed specification 
drawings.

A

 - Width excl. plaster kit

B

 - Width incl. plaster kit

C

 - Opening height

D

 -

 

Depth excl. plaster kit

E

 - Height

A

B

C

D

E

For detailed 

specification 

drawings 

please scan 

the QR code

MODEL

A

B

C

D

E

Electra 1500

1503mm 1535mm 414mm

299mm

587mm

Electra 1250

1253mm 1285mm 414mm

299mm

587mm

Electra-S 1350 1300mm 1300mm 414mm

325mm

636mm

Содержание ELECTRA - S 1350

Страница 1: ...A INSTRUCTION MANUAL INSTRUCTION MANUAL English English 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 ELECTRA 1500 ELECTRA 1250 ELECTRA S 1350 ...

Страница 2: ...ATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 EU Directives and UKCA Standards 3 Important Information and Health Safety 4 Components for Electra range 5 Built In Installation 6 Side glass installation 15 Front glass installation 17 Suite Installation 19 Log Layouts 24 Troubleshooting 26 Warranty 28 ...

Страница 3: ...th the following standards EU 2011 65 EU 2015 863 Restriction of Hazardous Substances EU 2011 65 EU 2015 863 Restriction of Hazardous Substances References to the relevant designated standards used References to the relevant designated standards used EN 55014 1 2006 A1 2009 A2 2011 Electromagnetic Compatibility EN 55014 1 2006 A1 2009 A2 2011 Electromagnetic Compatibility EN 55014 2 2015 Electroma...

Страница 4: ...arpets or rugs Do not allow the power lead to be coiled up once installed as this can cause overheating This appliance must be firmly fixed to or recessed into a flat internal wall A maintenance hatch must be installed into the surrounding installation to allow future access Always use a certified electrician should new circuits or outlets be required And always use properly grounded fused and pol...

Страница 5: ...Electrical Electrical Lead Lead Remote Remote Control Control Inset Inset Instruction Instruction Manual Manual Electra 1500 Electra 1500 British woodland 1500 British woodland 1500 Coconut husk Coconut husk YES YES 1 x 1 x 1 x 1 x 2 x 2 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x 1 x Electra 1250 Electra 1250 British woodland 1250 British woodland 1250 Coconut husk Coconut husk YES YES 1 x 1 x 1 x 1 x 2 x 2 x ...

Страница 6: ...6 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 INSTALLATION INSTALLATION ELECTRA 1500 ELECTRA 1250 ...

Страница 7: ...ply to all Evoflame and E Smart models Scan the QR code for more detailed specification drawings A Width excl plaster kit B Width incl plaster kit C Opening height D Depth excl plaster kit E Height A B C D E For detailed specification drawings please scan the QR code MODEL A B C D E Electra 1500 1503mm 1535mm 414mm 299mm 587mm Electra 1250 1253mm 1285mm 414mm 299mm 587mm Electra S 1350 1300mm 1300...

Страница 8: ...erted to be GF or GF2 depending on your preference This process only applies to Electra 1500 and Electra 1250 GF Configuration Glass Fronted A single glass panel at the front of the appliance GF2 Configuration Glass Fronted 2 A glass panel at the front and one side piece of glass The glass can be either side GF3 Configuration Glass Fronted 3 The standard configuration A glass panel at the front an...

Страница 9: ...S 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 INSTALLING THE SIDE PANELS CONVERTING TO GF GF2 1 Unscrew and remove the plaster kits from the side s of the appliance 2 Screw in the side panel s on one or both sides ...

Страница 10: ...esigned to be installed into either a stud and plasterboard wall or an existing chimney breast Please note that Open GF2 and GF3 models are not suitable for existing chimney breast installations If installing into an existing chimney make sure to adequately block off the flue The appliance must never be installed in front of an electrical socket The appliance must not be installed anywhere that it...

Страница 11: ...ISS 1 ELECTRA ISS 1 CHECKS BEFORE INSTALLATION We recommend turning on the appliance before installation connect the appliance to a power source using the provided electrical lead and depress the right side of the rocker switch Remove the electrical lead from the wall and continue with the installation ...

Страница 12: ...EMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 INSTALLATION STEPS 1 Remove the bottom transit brackets and side brace bars Then screw on the top mounted brackets and the IEC Clip on the back right ...

Страница 13: ...pliance in the design of your choosing When constructing the studwork remember that the vents on the underside of the appliance need a minimum of 50mm clearance beneath them Ensure that the appliance isn t supporting the weight of the studwork Before plasterboarding in the appliance it is recommended that you create a maintenance hatch for future access Do not use silicones adhesives or wet plaste...

Страница 14: ...ECTRA ISS 1 ELECTRA ISS 1 4 Your plasterboard can now line up with the plaster kits on the edge of the appliance 5 Alternatively the optional chrome side panels can be attached to the case with the magnets as shown below Ensure that the magnets are positioned with the short side touching the case ...

Страница 15: ...15 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 INSTALLING THE SIDE INSTALLING THE SIDE GLASS PANELS GLASS PANELS ...

Страница 16: ...ON MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 INSTALLING THE SIDE GLASS PANELS 1 Unscrew and remove the top and bottom glass retainer panels 2 Slide in the side glass pieces ...

Страница 17: ...PLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 INSTALLING THE FRONT INSTALLING THE FRONT GLASS PANEL GLASS PANEL Please Note The glass suction pad is an optional extra on both Electra built in models ...

Страница 18: ...ot using a glass sucker carefully hold the glass on either end and follow the same process 2 people may be required for this to ensure the glass is carefully supported at all times Then replace the top and bottom glass retainers Warning The Suction Lifter is provided to assist in moving the glass NEVER as the sole support of the glass Always support the glass throughout the entire process until th...

Страница 19: ...19 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 INSTALLATION INSTALLATION ELECTRA S 1350 ...

Страница 20: ...lled in front of an electrical socket The appliance must not be installed anywhere that it may come into contact with water i e a bathroom The minimum height above the finished floor level is 300mm INSTALLATION REQUIREMENTS CHECKS BEFORE INSTALLATION We recommend turning on the appliance before installation connect the appliance to a power source using the provided electrical lead and depress the ...

Страница 21: ...pplied with a wall bracket shown above INSTALLATION STEPS Drill Bit Wall Plugs Masonry type supplied Wall Screws Masonry type supplied Stud Detector For plasterboard installations only Wall Anchors For plasterboard installations only Not supplied 1 Remove the bottom mounted transit brackets you won t need these for installation Then screw on the IEC Clip to the bottom back of the case with the two...

Страница 22: ...and position that you want the appliance to be located Then secure the wall bracket to the wall in the position you need using the wall plugs and screws provided If you re not securing the appliance to a masonry wall you will need to use the appropriate fixings 3 Slide the appliance into the woodwork and screw through the pre attached brackets as shown ...

Страница 23: ...NSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 4 You can now hang the appliance on the wall by slotting the tabs of the wall bracket into the slots on the back of the appliance Connect the appliance to the mains power supply and it is ready to use ...

Страница 24: ...24 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 LOG LAYOUTS LOG LAYOUTS ...

Страница 25: ...0 log set Electra 1250 log set Electra 1500 log set When you have your appliance installed you can set up your log set s Lay the coconut husk on the fuel bed first then continue with laying out your logs There is no right or wrong way to arrange your logs the following images are an example of how you could lay them out LOG LAYOUTS ...

Страница 26: ...26 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 TROUBLESHOOTING TROUBLESHOOTING ...

Страница 27: ...struction manual for the new method E Smart Only E Smart LED Replacement Scan the QR code to be taken to a video in our maintenance series Please note this video shows an old method of removing the front glass panel Refer to page 24 of this instruction manual for the new method REPORT A FAULT If you have any difficulties or problems with your appliance then please get in touch so that we can assis...

Страница 28: ...ect to normal wear and tear or parts that require replacement in connection with normal maintenance are not covered within the extended warranty These items are covered for the first 12 months To make a warranty claim evidence must be supplied to our service department in the form of pictures videos or both Failure to supply evidence to support your warranty claim may invalidate or delay the claim...

Страница 29: ...ify the fault free of charge Nothing in the Extended Warranty shall make CK Fires Ltd liable for any or special incidental or consequential damages injury to persons or property or any other consequential loss beyond the consumer s statutory rights The liability on these issues is covered by our Terms and Conditions of Sale CK Fires Ltd total liability extends only to the purchase price paid for t...

Страница 30: ...n CV37 8HW Tel 44 0 1789 263868 Fax 44 0 1789 293080 Email sales evonicfires co uk www evonicfires co uk Follow us on Instagram Facebook Twitter LinkedIn evonicfires 30 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 ELECTRA ISS 1 ELECTRA ISS 1 ...

Отзывы: