background image

2

5.0 

GENERAL INSTALLATION

5.1 

The pump must be located as close as practical to the pool. The pump must also be in a 
position that enables easy access for periodic servicing.

5.2 

Care must also be taken to position the pump in an area that is free from flooding in a 
well-ventilated and dry location.

5.3 

The pump motor cooling fan must have a minimum clearance of 150mm (6”).

5.4 

The pump suction line should be not smaller than 40mm (1.5”).

5.5 

The suction line is to have as few bends or elbows as possible. There must not be an air 
trap on the suction line.

5.6 

Use only the pump barrel unions supplied with the pump.

5.7 

Ensure the pump is securely fastened to a level surface in the required position to 
prevent movement.

5.8 

The pump electrical cable must be wired for the proper voltage and rotation in 
accordance with the wiring instructions.

5.9 

All wiring and electrical work must be carried out by licensed electricians and installed 
in accordance with applicable local codes.

5.10 

The motor must be grounded.

5.11 

The weight of the plumbing and fittings is to be independently supported and not 
carried by the pump.

Содержание Evoflow TUF

Страница 1: ...echnician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty This manual contains important...

Страница 2: ...t exceeding 30mA be installed 2 5 Check the pumps nameplate for the following Voltage Amp draw and Cycle 2 6 The powercord includingthe groundwire shallhave a qualityof60245 IEC 66 H07RN F for models...

Страница 3: ...level of safety The manufacturer of the pump assumes no liability for the damage and injuries caused by unauthorised replacement parts and accessories 4 7 During operation some parts of the pump are...

Страница 4: ...s to have as few bends or elbows as possible There must not be an air trap on the suction line 5 6 Use only the pump barrel unions supplied with the pump 5 7 Ensure the pump is securely fastened to a...

Страница 5: ...start the pump Operating the pump with these valves shut can damage the pump 6 5 Start the pump 6 6 Allow a few minutes maximum for the pump to start delivering water 6 7 iWARNING High suction lift or...

Страница 6: ...must be taken to ensure the pump is protected from damage It is recommended that if the pump is not used during this winter period it should be drained completely Drain plugs can be supplied for this...

Страница 7: ...locked line Refer to Pump will not prime Motor runs hot Be aware some heat from motors is normal Do not touch hot motors Thermal overload protector will deactivate pump if there is an overload or high...

Страница 8: ...cated copyright in the content of this document is the property of Evolution Water and Lighting Solutions under Australian copyright law Unless otherwise indicated content may not be reproduced or tra...

Отзывы: