2
3.0
START UP PROCEDURE
3.1
The start up procedure for the filtration system can be followed for new systems or
after cleaning. In either case:
1. Ensure that all valves installed before or after the filter are open.
2. Ensure that the filter is plumbed correctly. Pipe from pump outlet must be attached
to the filter inlet port.
3. Loosen the air bleed screw on top of the filter lid.
4. Prime the swimming pool pump. Refer to the Pump Installation and Operation
Manual for correct pump priming procedures.
5. Turn on the swimming pool pump and allow the pump to run until all the air has
been expelled from the filter vessel. Water will run from the air bleed screw.
6. Retighten the air bleed screw.
7. The filter is primed and ready for operation.
3.2
In some cases this may be required to be done a few times before the unit will remain
primed and be fully operational.
3.3
i
CAUTION:
Do not stand over the lid whilst adjusting the air bleed to purge the system
of air. Injury may occur if air bleed screw comes loose.
4.0
MAINTENANCE
4.1
To ensure that you get maximum life from your Cartridge Filter, you will need to maintain
the filter regularly.
4.2
When the filter is first started and has been purged of air, note the pressure on the
pressure gauge. This initial pressure reading is what is known as the filter operation
pressure, and it is important that you be aware of this figure.
4.3
All filtration systems will operate at different pressures depending on the pool
hydraulics.
4.4
You will need to clean the filter cartridge element once the pressure gauge has reached
50kPa (7.2psi) above the operating pressure.
4.5
Evoclear Trim Series Cartridge Filters have a maximum operating pressure of
350kPa (50psi).