5. 

Maintenance 

5.1 

General Information 

EvoScann®  CANDI  is  designed  to  require  no  user  intervention  other  than  checking  electrical 
connections are sound for the connected equipment 

 
5.2 

Safety Information 

Observe all appropriate safety precautions when operating any electrical equipment. Always ensure 
wiring is done by competent persons in strict accordance with the electrical connection details in this 
document. 

Do not use abrasive or solvent substances to clean the unit. 

Do not attempt to open the EvoScann® CANDI. The unit is factory sealed and opening the unit will result 
in removal of any and all warranty. 

 
5.3 

Fault finding

 

Symptom: 

Check likely cause: 

Scanner not functioning 

 

 

Ensure Drivers are fully installed and operational. 

Ensure correct wiring connections are made. 

Ensure USB is connected to a functional Port 

 

Scanner reading incorrect pressures 

Check correct range is selected 

Scanner reading intermittently 

Check correct version of GUI is being used for P-

Series connected 

 

 

5.4 

Repair & Recalibration 

Field repair is not possible with EvoScann® CANDI. All repairs must be carried out by Evolution 
Measurement Ltd. 

To ensure optimum service and performance, return to Evolution Measurement Ltd. 

See contact us page. 

 
 
 
 
 
 
 
 
 

Содержание EvoScann CANDI ELE-CANDI-CANDI01

Страница 1: ...ved Doc No M 90223 Iss 1 Rev 1 P a g e 1 Evolution Measurement Ltd Product User Guide EvoScann CANDI CANbus to USB Converter P ELE CANDI CANDI01 Revision History Issue 1 Revision 0 First issued August...

Страница 2: ...ption 2 Technical Data 4 2 1 Specification 2 2 Dimensions 3 Installation Use 6 3 1 Unpack and Inspect 3 2 Drivers and GUI Installation 3 3 Electrical Connection 4 Operation 8 5 Maintenance 8 5 1 Gener...

Страница 3: ...GUI The CANDI is powered over a USB port on your personal computer and operation is enabled by installation of the required drivers and software provided on the USB Drive The CANDI and GUI allow for...

Страница 4: ...g CANDI Screw Terminal MKDS 3 5 USB Connection CANDI Micro USB Type B Female USB 2 0 PC USB A Female Supplied Lead Male USB A to Male USB Micro B 1 m Power Requirement USB 5 V 5 Note CANDI has an inte...

Страница 5: ...EvoScann CANDI Evolution Measurement Ltd 2021 All rights reserved Doc No M 90223 Iss 1 Rev 1 P a g e 5 2 2 Product Outline Dimensions EvoScann CANDI CANbus to USB Converter...

Страница 6: ...ual precautions necessary for a measurement instrument 3 1 Unpack and Inspect Remove all packaging materials from the unit and check for any damage If the unit has been damaged notify the supplier and...

Страница 7: ...ights reserved Doc No M 90223 Iss 1 Rev 1 P a g e 7 3 3 Electrical Connection Electrical Cable Identification Cable Identification YELLOW CANH GREEN CANL RED SUPPLY VSUP BLACK GND Note Check direction...

Страница 8: ...ration Operation of the EvoScann CANDI is simple and straightforward With the GUI running and the P Series electrically connected the scanner will immediately start to scan Below is a screenshot of a...

Страница 9: ...clean the unit Do not attempt to open the EvoScann CANDI The unit is factory sealed and opening the unit will result in removal of any and all warranty 5 3 Fault finding Symptom Check likely cause Sc...

Страница 10: ...hen not in use and store in a clean dry dust and moisture free area avoiding temperature extremes Avoid the risk of droppage vibration or other unnecessary impact 6 2 Disposal At end of life dispose o...

Страница 11: ...ailable 1 Sensor No Serial Number Firmware P Series Firmware Revision Period Set Period of P Series CAN ID Set CAN ID of P Series Hex CAN ID SR Set CAN ID of the Slow Row data when in 7 Byte mode Auto...

Страница 12: ...Changes Serial Number Not Recommended New ID Changes Can ID Barometric Allows user to enter barometric pressure read from a transfer standard or similar to enable correction of output Absolute Units...

Страница 13: ...ights reserved Doc No M 90223 Iss 1 Rev 1 P a g e 13 Logging Tab Press the file icon the route path can now be set for the log file Click Sensor Number to create individual log file Record Starts the...

Страница 14: ...eserved Doc No M 90223 Iss 1 Rev 1 P a g e 14 Contact us Evolution Measurement Ltd 7 Regents Court South Way Walworth Business Park Andover Hampshire SP10 5NX UK Telephone 44 0 1264 316470 Email enqui...

Отзывы: