Evolution Aqua nexus 310 Скачать руководство пользователя страница 14

The difference is clear at  www.evolutionaqua.com

13

NEXUS 310 GRAVITY FED INSTALLATION

OPERATING YOUR NEXUS 310 GRAVITY FED

Once your Nexus is installed and plumbed in as instructed, you are ready to fill the Nexus 

and begin filtering your pond water.

To fill your Nexus first you need to open all the valves before and after the Nexus. 

The system should be filled until the water levels are equal.

Once the Nexus is full, you will notice that the K1 Media in the outer chamber, 

will float on the surface of the water. In a pond containing fish the media will begin 

moving completely within a week, this is perfectly normal. 

Now your Nexus is full it is time to turn on your air pump to circulate the media making 

sure the air valve to the outer chamber is open and the air valve to the Eazy is closed. 

CLEANING YOUR NEXUS 310 GRAVITY FED

The central ‘Eazy’ section of the Nexus will collect all the debris and suspended solids that 

come into the filter. In time you will find out how often you need to clean this, and 

probably get into a routine to keep the filter working at its optimum. Each pond is different, 

and the regularity of cleaning is affected by stocking levels and feeding rates along with 

other factors such as algae in the pond.  

WHEN TO CLEAN? 

You may also notice that the water level in the outer chamber – the 

Biological stage – lowers as water is prevented from getting through the Eazy as quickly as 

it is being pumped back into the pond. When this water level falls beneath the level of the 

bypass pipe, this is the indication that you should clean the Eazy. Normally we would not 

recommend leaving the filter uncleaned more then 3 weeks. The filter can be left longer if 

absolutely necessary but this would not be best practice.

Cleaning procedure

1. 

Switch off your circulation pump. 

2. 

Close the inlet to the Nexus by inserting inlet slide-plate  supplied with your  

 

 

Nexus. Your Eazy is now isolated from the rest of the system

3. 

Turn the air valve to divert the air into the Eazy, close the air valve to the bio stage.

4. 

The K1 media in the Eazy will now be agitated vigorously, or ‘boil’. As this happens,  

 

all the debris trapped in the K1 will be released into the vortex area of the 

 

central chamber.

5.     After about 5 minutes, open the waste valve (G), allowing the waste to drain out   

 

with the water.

6.     Close the waste valve (G).

7.     Take out the slide plate 

8.  

We would recommend that you perform the cleaning process twice wherever    

 

possible to ensure best results. 

9. 

Close the air valve, to the inner chamber and open the air valve to the 

 

outer chamber. 

10. 

Switch on your circulation pump.

LONGER PERIOD OF TIME BETWEEN CLEANING

Regular cleaning of the Eazy is essential to maintain your pond at its best. Build up of 

detritus in any pond filter can harbour pathogens, and other pollutants which may 

harm your fish.

At times, you may want to leave your filter for longer than you would normally want 

between cleaning, perhaps if you go on holiday. In these instances, your Nexus 310 incor-

porates a Bypass, which will prevent the bio stage from emptying, and therefore potentially 

starving your pump of water, should your Eazy become full of debris. The filter bypass should 

be turned 90 degree as per figs. 7.1-7.3, when you need to leave your filter for longer peri-

ods of time such as holidays etc. this will allow the water to bypass the eazy should it be

-

Содержание nexus 310

Страница 1: ...Evolution Aqua Ltd Evolution House Kellet Close Wigan WN5 0LP England 44 0 1942 216554 Filtration System Installation and instruction manual N31011311131MAN...

Страница 2: ...ns back into your pond via gravity i e down a waterfall or through a large diameter pipe this is referred to as PUMP FED i e the water is fed to the filter using a pump ARE YOU GRA VITY FED By this we...

Страница 3: ...ed media 14 How to get the best from your Nexus filter 15 Your Nexus comes complete with the following items TABLE OF CONTENTS Hose tail inlet assembly for use in pump fed setup only Bypass collar use...

Страница 4: ...K1 media 40L for Nexus 310 which is located within the centre chamber of the Nexus After water en ters the Nexus it rotates around the Eazy in the centre chamber with a downward motion al lowing the...

Страница 5: ...Evolution Aqua Ltd Evolution House Kellet Close Wigan WN5 0LP England 44 0 1942 216554 4 Filtration System Pump fed installation and operation manual...

Страница 6: ...ot sufficient to support the Nexus using just blocks underneath the feet as this could lead to damage to the Nexus Incorrect installation will render the warranty invalid Check all the jubilee clips o...

Страница 7: ...ems are always installed after the pump NEXUS 310 PUMP FED INSTALLATION Your Nexus 310 has been supplied to you ready for you to set up for Pump fed operation Pump Fed Installation Steps 1 Attach the...

Страница 8: ...e line where it can pump directly to waste Once your Nexus is installed and plumbed in as described above you are ready to fill the Nexus and begin treating your pond water OPERATING YOUR NEXUS 310 PU...

Страница 9: ...his would not be best practice Cleaning procedure 1 Close the valve at the Nexus inlet and immediately switch off your pump 2 Close the inlet to the inner chamber by inserting inlet slide plate suppli...

Страница 10: ...The difference is clear at www evolutionaqua com 9 Filtration System Gravity fed installation and operation manual...

Страница 11: ...low where you want the finished pond water surface to be Please see diagrams below The water on a Gravity fed system should be fed from an appropriately placed bottom drain through at least a 4 inch 1...

Страница 12: ...3 1 2 Attach the 4 2 eazyconnector Fig 3 3 to the Nexus Outlet F Fig 3 2 3 Attach the 4 4 eazyconnector to the Nexus Inlet A Fig 3 4 and then to the 4 pipe work from your pond 4 Connect your water pum...

Страница 13: ...an be connected using a waste pipe kit optional extra as shown in Figs 6 1 3 or can just be discharged individually If the Nexus is located below your drain height the waste can be either discharged i...

Страница 14: ...rmally we would not recommend leaving the filter uncleaned more then 3 weeks The filter can be left longer if absolutely necessary but this would not be best practice Cleaning procedure 1 Switch off y...

Страница 15: ...om the water As the K1 media chaotically circulates within the bio tank it causes old dead bacteria bio film on the outside to be removed making space for new younger heavier feeding bacteria bio film...

Страница 16: ...bed The Pure Pond balls are made from a biodegradable polymer and crammed full of bacteria that are slowly released when they are needed most When you introduce the Pure Pond balls into the biologica...

Страница 17: ...2 Though the warranty period may not have expired payment for repairs must be made in the following cases a When the fault is due to misuse or unauthorised repairs have been attempted b When the fault...

Страница 18: ...orm will amount to your consent for us to disclose your details and other personal information to other companies within the Evolution Aqua group including any subsidiary company or subcontractor of E...

Отзывы: