CETUS I NSTALLATI ON
-3-
The C e tus ne e d s to b e insta lle d o n a so lid le ve l b a se so tha t it d o e snt d e
fl
e c t
und e r its o wn we ig ht. It is re c o m m e nd e d to use a 100m m thic k c o nc re te p linth,
a ltho ug h d e c king o r p a ving sla b s
c a n b e use d .
During insta lla tio n a sp irit le ve l
sho uld b e use d a c ro ss the m e ta l
p la te o n the we ir to m a ke sure the
C e tus is le ve l a s sho wn in Fig ure 3.
This will e nsure tha t the wa te r
fl
o ws
e ve nly a c ro ss the sc re e n.
Pipe Size s
Pip e d ia m e te r d e te rm ine s the p re ssure lo ss within the p ip e , so fo r
fl
o ws whe re
g ra vity is the d riving fo rc e , la rg e b o re p ip e (4” / 110m m ) ne e d s to b e use d .
The re fo re in a g ra vity fe d syste m , the inle t (the line fro m the b o tto m d ra in o r
skim m e r) ne e d s to b e 4” (110m m ) a nd a lso in a p um p fe d syste m the re turn line
fro m the C e tus to yo ur p o nd o r
fi
lte r ne e d s to b e 4” (110m m ). Whe n
fl
o ws a re
und e r 10,000 L/ hr it is p o ssib le to use 3” (90m m ) p ip e inste a d .
C irc ula ting Pum p Insta lla tio n
Fig 3
Whe n insta lling yo ur p um p o n a g ra vity fe d syste m , the p um p m ust b e insta lle d
lo we r tha n the le ve l o f the o utle t to p re ve nt a irlo c ks within the p um p .
Also if the re is a ny c ha nc e o f b a c k sip ho ning , a o ne wa y va lve m ust b e
insta lle d a fte r the p um p to p re ve nt the C e tus
fi
lling with wa te r.
Te c hnic a l Info rm a tio n
Ma x Flo w
18,000 L/ hr
Inle t
4” (110m m ) G ra vity
1.5” (50m m ) Pum p
O utle t
1.5” (50 m m ) G ra vity
3” (90m m ) Pum p Ne e d 4” a d a p te r whe n
fl
o w o ve r 10,000 L/ h
Wa ste O utle t
3” (90m m )
He ig ht
945 m m
Le ng th
850 m m
Wid th
570 m m
Sc re e n Size
300 m ic ro n