Set up 

o

 

Control panel

 

The  control  board  offer  several  features:  you  can  simple  set  the  starting  address,  run  the  pre-
programmed program or make a reset. 

 

The main menu is accessed by pressing the Menu button, Browse through the submenu by pressing 
Up  or  Down.  Press  the  Enter-button  in  order  to  select  the  desired  menu.  You  can  change  the 
selection  by  pressing  Up  or  Down,  confirm  every  selection  by  pressing  the  Enter-button.  The 
functions provided are described in the following setting.  

 

 

 

Menu 

DMX 
Address  001-512 

 

 

 

DMX 
Mode 

1CH 

 

 

 

2CH 

 

 

 

4CH 

 

 

 

6CH 

 

 

 

8CH 

 

 

 

11CH 

 

 

 

Stand 
Alone  

Auto 

Program 1 

Dim 

000-255 

Program 2 

Speed 

000-255 

Program 3 

 

 

..... 

 

 

Program 17  MIXED 

 

ColorMacro 

Color Off 

000-005   

Color1~46 

006-255   

Manual 

Dimmer 

000-255   

Strobe 

0~30Hz 

 

Red 

000-255   

Green 

000-255   

Blue 

000-255   

White 

000-255   

CCT 

OFF 

 

3000K/3500K/4500K/5500K/7500K 

Button 

Function 

 

<MENU> 

Scrolls through the first level of options, or exits from the current menu or 
function 

 

 

 

<UP> 

Navigates upward through the menu list or increases the numeric value 
when in a function 

 

 

 

<DOWN> 

Navigates downward through the menu list or decreases the numeric value 
when in a function 

 

 

 

<ENTER> 

Enables the currently displayed menu or sets the currently selected value in 
to the current function 

Содержание PARCOB 150 RGBW IP

Страница 1: ...PARCOB 150 RGBW IP Manual Ver 1 00 Page1 PARCOB 150 RGBW IP 150W LED RGBW 4in1 ip65 projector User manual Mode d emploi...

Страница 2: ...avec terre Toujours d brancher l appareil avant une intervention technique ou avant son entretien Ne pas brancher cet appareil sur un bloc de puissance variable type Dimmer pack ATTENTION Risque de b...

Страница 3: ...ue aux vibrations produites par la machine en fonctionnement L accroche de l appareil doit tre s curis e par une lingue de s curit Assurez vous galement que la structure ou point d accroche peut suppo...

Страница 4: ...4en1 Consommation lectrique 150 W Canaux DMX 11 canaux DMX Fr quence de rafraichissement r glable 900 Hz 10 000 Hz Courbe de gradation 4 modes de courbe de gradation 6 modes DMX 1CH 2CH 4CH 6CH 8CH 11...

Страница 5: ...serr convenablement afin d viter toute chute due aux vibrations produites par la machine en fonctionnement L accroche de l appareil doit tre s curis e par une lingue de s curit Assurez vous galement...

Страница 6: ...t conformes au Standard IEC Configuration o Panneau de contr le Navigation dans les menus Panneau de contr le avec afficheur Bouton Fonction MENU Fait d filer le premier niveau d options ou quitte le...

Страница 7: ...ColorMacro Color Off 000 005 Color1 46 006 255 Manual Dimmer 000 255 Strobe 0 30Hz Red 000 255 Green 000 255 Blue 000 255 White 000 255 CCT OFF 3000K 3500K 4500K 5500K 7500K Settings Display Reverse O...

Страница 8: ...ode Smart Max Silent PWM Rate 900Hz 1000Hz 1100Hz 1200Hz 1300Hz 1400Hz 1500Hz 2500Hz 4000Hz 5000Hz 6000Hz 10000Hz Service Reset Passcode Code down down down up down down down up 11 Calibration Passcod...

Страница 9: ...eur FONCTIONS 1 000 255 MASTER DIMMER 0 100 2 COLOR MACROS 000 No Effect 001 255 Color 1 46 o Protocole DMX 4 canaux 4 CH VALUES FUNCTIONS 1 000 255 RED 0 100 2 000 255 GREEN 0 100 3 000 255 BLUE 0 10...

Страница 10: ...cole DMX 8 canaux 7 CH VALUES FUNCTIONS 1 000 255 MASTER DIMMER 0 100 2 000 255 DIMMER FINE 0 100 3 000 255 RED 0 100 4 000 255 GREEN 0 100 5 000 255 BLUE 0 100 6 000 255 WHITE 0 100 7 SHUTTER STROBIN...

Страница 11: ...090 Strob slow to fast 091 100 LED ON 101 110 LED OFF 111 170 Pulse Strobing 171 180 LED On 181 240 Random Strobing Slow Fast 241 255 LED On 8 000 255 Blinder Mode Channel 0 100 RedShift Override othe...

Страница 12: ...141 255 Default to Unit Setting 11 REFRESH RATE 000 010 Default to Unit Setting 011 020 900HZ 021 030 1000HZ 031 040 1100HZ 041 050 1200HZ 051 060 1300HZ 061 070 1400HZ 071 080 1500HZ 081 090 2500HZ...

Страница 13: ...portant D branchez l appareil avant toute intervention Utilisez un chiffon propre et sec o Maintenance DANGER Risque de chocs lectriques Toujours d brancher l appareil avant une intervention technique...

Страница 14: ...150 RGBW IP Manual Ver 1 00 Page14 Caract ristiques techniques Mod le PARCOB 150 RGBW IP Voltage 110V 250V 50 60Hz Consommation 150W LEDs 1x 150 Watts RGBW 4in1 Poids net 3 5 kg Dimensions 307 x 234 x...

Страница 15: ...e Risk of electric shock ALWAYS disconnect the fixture from power for servicing for cleaning or installing Do not connect this unit on a dimmer power pack Protect the unit from rain or moisture WARNIN...

Страница 16: ...ures and professional lighting effects for a long period of time This evolite fixture is complying with European standards EN60598 1 2008 A11 2009 EN60598 2 17 1989 A2 1991 et RoHs Device Description...

Страница 17: ...PARCOB 150 RGBW IP Manual Ver 1 00 Page17 1 Menu 2 Pressure valve 3 DMX IN DMX OUT 4 POWER IN POWER OUT...

Страница 18: ...professional structural rigger Improper installation can result in bodily injury and or damage to property The projector had to be installed out of the reach of people Always secure your fixture with...

Страница 19: ...enu DMX Address 001 512 DMX Mode 1CH 2CH 4CH 6CH 8CH 11CH Stand Alone Auto Program 1 Dim 000 255 Program 2 Speed 000 255 Program 3 Program 17 MIXED ColorMacro Color Off 000 005 Color1 46 006 255 Manua...

Страница 20: ...mer Curve Linear Stage TV Architectural Theatre Stage2 Dimmer Speed 0 1 0 9s 1 10S Only for stage2 curve AutoLock On Off Fan Mode Smart Max Silent PWM Rate 900Hz 1000Hz 1100Hz 1200Hz 1300Hz 1400Hz 150...

Страница 21: ...essed with same DMX value they will move exactly the same way 1 DMX Channel 1 CH VALUES FUNCTIONS 1 000 255 Blinder Mode Channel 0 100 RedShift Override other dimmer channel 2 DMX Channels 2 CH VALUES...

Страница 22: ...obing Slow Fast 241 255 LED On 8 DMX Channels 7 CH VALUES FUNCTIONS 1 000 255 MASTER DIMMER 0 100 2 000 255 DIMMER FINE 0 100 3 000 255 RED 0 100 4 000 255 GREEN 0 100 5 000 255 BLUE 0 100 6 000 255 W...

Страница 23: ...ED Off 031 090 Strob slow to fast 091 100 LED ON 101 110 LED OFF 111 170 Pulse Strobing 171 180 LED On 181 240 Random Strobing Slow Fast 241 255 LED On 000 030 LED Off 8 000 255 Blinder Mode Channel 0...

Страница 24: ...7 7 0Sec 138 8 0Sec 139 9 0Sec 140 10Sec 141 255 Default to Unit Setting 11 REFRESH RATE 000 010 Default to Unit Setting 011 020 900HZ 021 030 1000HZ 031 040 1100HZ 041 050 1200HZ 051 060 1300HZ 061 0...

Страница 25: ...ried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation o...

Страница 26: ...ttent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one o Try to use another DMX controller o Check if the DMX cables run near or run alongside to high volt...

Страница 27: ...PARCOB 150 RGBW IP Manual Ver 1 00 Page27 www evolite pro com Import par Imported by EVOLITE MSC 7 avenue du 1er Mai 91120 Palaiseau FRANCE infos msc distribution com Tel 33 1 69 34 80 62...

Отзывы: