Installation   
 

o

 

Rigging  

The installation of the projector has to be built and constructed in a way that it can hold 10 times the 
weight for 1 hour without any harming deformation. 
IMPORTANT!OVERHEAD  RIGGING  REQUIRES  EXTENSIVE  EXPERIENCE,  including  calculating  working 
load limits, installation material being used, and periodic safety inspection of all installation material 
and the projector. If you lack these qualifications, do not attempt the installation yourself, but instead 
use a professional structural rigger. Improper installation can result in bodily injury and or damage to 
property. The projector had to be installed out of the reach of people 
 

 

 

 

 

Always secure your fixture with a safety cable!

 

 
 

o

 

DMX 512 Connection 

 

 

The wires must not come into contact with each other, otherwise the fixture will not work at all or 
properly. Please note the starting address depends upon which controller is being used. Only use a 
DMX cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or 
one fixture to another  

 

 

Connection with the mains. 

 

The earth has to be connected. The device must only be connected with an electric installation carried 
out in compliance with IEC standards.  

 
 
 
 
 

Содержание 55696

Страница 1: ...MaxBAR 180 Manual Ver 1 00 Page1 MaxBAR 180 36 X 5W RGB LED Bar User manual Mode d emploi...

Страница 2: ...ue ou avant son entretien Ne pas brancher cet appareil sur un bloc de puissance variable type Dimmer pack Afin de r duire et d viter tout risque d lectrocution ou d incendie ne pas utiliser cet appare...

Страница 3: ...ux vibrations produites par la machine en fonctionnement L accroche de l appareil doit tre s curis e par une lingue de s curit Assurez vous galement que la structure ou point d accroche peut supporter...

Страница 4: ...nts de couleurs 36 LED de 5W RGB 9 courbes de dimmer Angle du faisceau de 60 Refroidissement forc par ventilateur Alimentation sur connecteur Powercon IN OUT Alimentation lectrique 110V 250V 50 60Hz C...

Страница 5: ...erre ou Earth doit toujours tre connect e Les c ble d alimentation doivent tre homologu s et conformes au Standard IEC Configuration o Panneau de contr le Navigation dans les menus Panneau de contr le...

Страница 6: ...du vert 3 0 255 Intensit du bleu o Protocole DMX 9 canaux STAG CH DMX data Function Description 1 0 255 Dimmer Dimmer lin aire de 0 100 2 0 255 Intensit du rouge 3 0 255 Intensit du vert 4 0 255 Inten...

Страница 7: ...34 Vitesse dim lin aire dIM OFF 35 59 Vitesse dim non lin aire 1 dIM 1 60 84 Vitesse dim non lin aire 2 dIM 2 85 109 Vitesse dim non lin aire 3 dIM 3 110 134 Vitesse dim non lin aire 4 dIM 4 135 159...

Страница 8: ...4 Vitesse dim non lin aire 4 dIM 4 135 159 Vitesse dim non lin aire 5 dIM 5 160 184 Vitesse dim non lin aire 6 dIM 6 185 209 Vitesse dim non lin aire 7 dIM 7 210 255 Vitesse dim non lin aire 8 dIM 8 o...

Страница 9: ...bl mes avec votre appareil L appareil ne fonctionne pas du tout o V rifiez le cordon d alimentation et le fusible o Assurez vous que votre prise soit bien aliment e L appareil ne r pond pas ou pas cor...

Страница 10: ...sk of electric shock ALWAYS disconnect the fixture from power for servicing for cleaning or installing Do not connect this unit on a dimmer power pack Protect the unit from rain or moisture WARNING Bu...

Страница 11: ...This evolite fixture is complying with European standards EN60598 1 2008 A11 2009 EN60598 2 17 1989 A2 1991 et RoHs Device Description Wash LED Bar LED Type 36pcs 5W RGB 3in1 super bright LED Drive C...

Страница 12: ...fessional structural rigger Improper installation can result in bodily injury and or damage to property The projector had to be installed out of the reach of people Always secure your fixture with a s...

Страница 13: ...etting Item Menu Sub menu 3rd menu Function Description STATIC Red Static color setting Green Blue White Strobe AUTO Auto effect 1 Auto effect choosing Auto effect 2 Auto effect 3 Auto effect 4 Auto e...

Страница 14: ...0 BLUE 100 110 129 RED 100 GREEN 0 BLUE DOWN 130 149 RED 100 GREEN UP BLUE UP 150 169 RED DOWN GREEN DOWN BLUE 100 170 255 RED 100 GREEN 100 BLUE 100 WHITE 100 6 000 015 NO FUNCTION STROBE 016 215 No...

Страница 15: ...ear dimming speed 5 dIM 5 160 184 Non linear dimming speed 6 dIM 6 185 209 Non linear dimming speed 7 dIM 7 210 255 Non linear dimming speed 8 dIM 8 o DMX Protocol 5 channel ARC 3 D CH DMX data Functi...

Страница 16: ...4 Non linear dimming speed 2 dIM 2 85 109 Non linear dimming speed 3 dIM 3 110 134 Non linear dimming speed 4 dIM 4 135 159 Non linear dimming speed 5 dIM 5 160 184 Non linear dimming speed 6 dIM 6 18...

Страница 17: ...ent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one o Try to use another DMX controller o Check if the DMX cables run near or run alongside to high voltag...

Страница 18: ...MaxBAR 180 Manual Ver 1 00 Page18 www evolite pro com Import par Imported by EVOLITE MSC 7 avenue du 1er Mai 91120 Palaiseau FRANCE infos msc distribution com Tel 33 1 69 34 80 62...

Отзывы: