5. Installation 

5.1 System Installation 

Upon receiving the unit, check the packaging for any obvious signs of damage. Inform EvoHeat immediately if there is 
any evidence of rough handling.  

 

Do not drill any fixings or attachments into the outer 

casing of the tank. Drilling into the outer casing of the 

tank may damage the heating coil and WILL VOID 

WARRANTY. 

 

The P&T valve attached with the unit must be installed. 

Failure to do so will cause damage to the unit and 

possible personal injury. 

 

Drain the water tank through the drain valve at the 

bottom part of the unit. 

 

Do not use stainless steel fittings to connect directly with 

other metals to prevent galvanic corrosion. 

 

Note:

 A pressure releasing valve is to be fitted within the installation. Spec of P&T valve: Pressure: 0.85MP Temperature: 99°C 

 

 

Water Inlet or Outlet Pipes:

 The specification of 

the water inlet and outlet thread is BSP3/4 (internal 
thread). Pipes must be heat-resistant and durable. 
 
 

Piping for the P&T Valve:

 

The spec of the valve 

connecting thread is BSP3/4 (internal thread). After 
installation, confirm that the drainpipe outlet is 
exposed in the air. When the flexible drainpipe is 
joined to the pressure relief orifice of this valve, 
ensure that the flexible drainpipe is pointing 
downwards and exposed in the air. 

 

5.2 Handing & Transportation 

The unit should be stored and/or transported in its shipping container in an upright position and without water charge. 
For transport over short distances, and provided due care is exercised, an inclination angle of up to 30 degrees is 
permitted. During transport and storage, ambient temperatures of -10 to +60 degrees Celsius are permissible. 
 

Forklift Transportation 

Manual Transportation 

The unit must remain mounted on the pallet 

and lifted at minimal speed. Due to its top 

heaviness, the unit must be secured against 

tipping over and placed on a level surface. 

Ensure that the maximum permissible inclination angle of 60 

degrees is not exceeded. If transport in an inclined position 

cannot be avoided, the unit should be left to rest at least one hour 

after it has been moved into final position before operation. 

 

 

Содержание EVO150-1

Страница 1: ......

Страница 2: ...7 6 1 The Controller 7 6 2 Operating Functions 8 6 2 1 Startup Shutdown 8 6 2 2 Switching Modes 8 6 2 3 Locking the Controller 8 6 2 4 Setting Checking the Target Temperature 9 6 2 5 Hydroboost Setti...

Страница 3: ...ergy efficiency technologies and built in smart features to ensure you re provided with clean safe and economical hot water all year round Conforms to AS 3498 2009 Australia and New Zealand Measuremen...

Страница 4: ...year d Press at any stage to cancel 3 Press until is displayed This will activate Eco Heating Heat Pump only mode and will provide the most efficient heating 4 During periods of unusually high hot wa...

Страница 5: ...you restart the unit or turn it on manually the unit will not start to run again for approximately 3 minutes This is a protection feature to safeguard the compressor The handle of the P T safety valv...

Страница 6: ...eat resistant and durable Piping for the P T Valve The spec of the valve connecting thread is BSP3 4 internal thread After installation confirm that the drainpipe outlet is exposed in the air When the...

Страница 7: ...es to allow airflow to circulate through the unit it is advised to keep a minimum gap between walls fences etc of 300mm on the air inlet side 500mm on the air outlet side 100mm overhead rear clearance...

Страница 8: ...water temperature and target temperature The electric heater always will be off INTELLIGENT MODE The unit will automatically judge the operation mode according to the ambient temperature HIGH REQUIRE...

Страница 9: ...for 0 5 seconds in the running screen of the controller to turn the unit off The main display will now show OFF The unit will dim the screen and display the standby screen when the controller has not...

Страница 10: ...5 Hydroboost Setting Also known as the Electric heater the Hydroboost setting allows higher levels of hot water to be produced When there are high hot water usage requirements such as guests staying t...

Страница 11: ...rameter value as shown in the below table and press the key to open that value Change the value using the up down arrow keys and press the key to save changes Press to exit the menu Description Parame...

Страница 12: ...t up time A and end time B Press to save the setting and exit back to the main interface Press and hold for 2 seconds the timer display will flash When the timer display flashes choose the start up ti...

Страница 13: ...sh when it is selected use the arrow keys to select your desired start day then press to save all changes and exit back to the main interface Note Format is mm dd Example The unit will start up on Sep...

Страница 14: ...ck or change the anti freeze temp sensor Solar temp failure P034 The solar temp sensor is open or short circuit Check or change the solar temp sensor High pressure protection E01 The exhaust pressure...

Страница 15: ...e module must be placed with the cord coming downwards to protect it from water COMP RED WHT CR CC CS N WHT N N N 1 3 2 4 5 6 7 8 01 TO POWER SUPPLY 220 240V 50Hz 5 EEV COMP Compressor FM Fan motor CT...

Страница 16: ...th the water heater 8 4 Using the Overheating Protector The overheating protector is used to turn the power off in an emergency or with power supply issues preventing the water from being heated too h...

Страница 17: ...clean of the unit with a damp cloth MAJOR FIVE YEAR SERVICE It is recommended a major five 5 year service be conducted on the Evo150 1 Warning Servicing of a water heater must only be carried out by...

Страница 18: ...ed within the i Costs associated with delivery handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 o...

Отзывы: