background image

 

 

 

EVoInnovate™ EVSE 

 

Model Numbers: EVO32-300-001 & EVO32-300-002 

User Manual & Installation Guide 

Revision 1.0 

 

 

 

Содержание EVoInnovate EVO32-300-001

Страница 1: ...EVoInnovate EVSE Model Numbers EVO32 300 001 EVO32 300 002 User Manual Installation Guide Revision 1 0...

Страница 2: ...The information provided in this manual in no way exempts the user of responsibility to follow all applicable codes or safety standards This document provides instructions for the charging station and...

Страница 3: ...is device must accept any interference received including interference that may cause undesired operation OVERALL WARNINGS CAUTIONS WARNING RISK OF ELECTRIC SHOCK Basic precautions should always be fo...

Страница 4: ...r Robust Construction Certified for Outdoor Use Robust durable design tamper resistant features NEMA 4 certified for outdoor and indoor use Simple Operation No user interface required with EVSE simply...

Страница 5: ...in instance where an existing 30A or 20A dedicated circuit is already installed Security and Tamper Feature In addition to the lock screw that secures the EVoInnovate charging station to the wall moun...

Страница 6: ...33 ft with EVoReel P N EVO30 201 001 Electrical Circuit Input Power Requirements 208 240VAC 50 60 Hz Circuit Requirement Dedicated Branch Breaker Double pole Circuit Conductors Line 1 Line 2 Earth Gro...

Страница 7: ...ting the Charging Station Maximum Current Output Setting Optional 9 Tools Parts Required for Installation 11 Install the Charging Station 11 Input Wiring Connection Optional Hardwire Connection Only 1...

Страница 8: ...er as well as the Mounting Fasteners for both the Charging Station Mounting Bracket and Connector Cable Holder these items are packaged within a compartment of the charging station cardboard packaging...

Страница 9: ...Charging Station Per National Electric Code NEC requirements 32A Maximum Output Setting Default Factory Setting a DEDICATED CIRCUIT rated for 40A 208 240 VAC 50 60 Hz Single Phase must be used Circuit...

Страница 10: ...lt Factory Maximum Current Output Setting is 32A 7 68 kW for use with a 40A or greater Circuit Rating To adjust the Maximum Current Output Setting when using a 30A or 20A Circuit Rating 1 Place the Ch...

Страница 11: ...harness to the charging station circuit board and install the charging station font cover using the following torque force to secure the 5 Torx screws Screw Torque M4 16 kgf cm 13 88 lb in CAUTION Th...

Страница 12: ...on Heat Shrink Tube x3 For 8 AWG wire Commercially Available Only Required for Optional Hardwire Connection Terminal x3 For 8 AWG wire Commercially Available Only Required for Optional Hardwire Connec...

Страница 13: ...M6 tapping screws Supplied b For masonry walls use M6 mechanical screws Commercially available c Use following torque force Screw Torque M6 50 kgf cm 43 4 lb in 1 4 50 kgf cm 43 4 lb in 4 As shown in...

Страница 14: ...ing bracket Figure 2 4 Screw locking position 5 For Plug in NEMA 6 50 models Plug in the power cord to the NEMA 6 50 Wall Outlet Receptacle The NEMA outlet should be located no less than 20 26 from th...

Страница 15: ...inal heat shrink tube and copper wire 9 Connecting the electrical wiring to the charging station 9 1 Place the Charging Station on a flat surface front cover down with protection under the cover to av...

Страница 16: ...Plug Loosen the Strain Relief Fitting for the NEMA 6 50 Plug and Remove the Plug 9 5 Insert the wire end passing through the conduit and insert them into the input wiring hole Use Red wire for L1 Blac...

Страница 17: ...ll the charging station font cover using the following torque force to secure the 5 Torx screws Screw Torque M4 16 kgf cm 13 88 lb in Install the Plug and Cable Holder 1 Separate the holder from hook...

Страница 18: ...VSE User Manual Installation Guide www evocharge com 17 3 Position the plastic holder insert face up and install into the holder bracket Figure 2 10 Secure the holder 4 Next rotate the holder insert d...

Страница 19: ...tighten the 2 lock set Philips screws located at the top of the plastic holder component until snug do not overtighten The screws ensure that the plastic holder component remains secured to the holde...

Страница 20: ...d Steady Unrecoverable Fault Red Flashing Recoverable Fault Yellow Steady Out of Service Yellow Flashing Booting Firmware Upgrade in process Note In the instance the Red Steady or Red Flashing Fault l...

Страница 21: ...l automatically restart charging when the cause of the temporary error condition returns to normal The status indicator lights remain flashing RED until the error condition is resolved Temporary error...

Страница 22: ...f the product components Despite the water resistance of the enclosure when cleaning it is preferred to not direct streams of water at the unit clean with a water damp automotive grade soft cleaning c...

Отзывы: