KH407 6 TWIN BOOM
4.4
If a two battery system is going to be used, replace the first battery once
charged, with the second battery. Charge using the same procedure as
above.
NOTE:
A battery pack may remain on charge indefinitely without any detrimental effects to
the battery or charging unit.
Fig 4 Charger unit shown without battery attached.
4.
BATTERY CARE:
The hoist uses fully sealed lead acid batteries. They are designed to be recharged
on a regular basis. To care for your batteries and obtain the maximum life
DO NOT
allow the batteries to run totally flat before recharging.
The controller is fitted with an
audio low battery warning alarm
. When this
warning alarm sounds complete the lift process, then change the battery and
recharge. Kerry Equipment recommends that a 2-battery system be used, this
allows one battery to always be on charge while the other is in use, hence the hoist
may never be out of service with a flat battery.
MAINTENANCE INSTRUCTIONS
LUBRICATION
The hoist requires periodical lubrication. These points are:
1.
CASTORS
It is always best practice to remove all hair and lint from the castors as soon as possible,
always allowing free movement of all the wheels.
The castors need to be lubricated monthly (Use TAC-2 only). This involves: -
1.1 The Castor head bearing will need lubricating. Simply spray TAC-2 up into the
bearing while rotating the castor (Fig 5).
1.2
The wheel also requires lubricating every couple of months. To do this the
wheel must be unbolted and removed from the castor frame. TAC-2 can
then be sprayed into the hub centre to lubricate the internal bearings (Fig 6).
Fig5
Fig 6