Installing the Product
M60 SERIES
· 17 ·
2. Low space -Y > L: below the PC, there should be a space at least the same size as
the largest dimension of the PC;
3. There should be at least 0.5L space for the other four directions (front, rear, left,
right);
4. In the above heat exchange areas, there should be no other heat generating object or
space divider, and no other article is allowed to be placed on the surface of chassis;
5. There should be heat exchange channel between heat exchange area and outside
natural environment, such as air moving equipment, and air inlet/outlet to ensure air
circulation, etc.;
6. The temperature of lower space (20
~
50mm from the bottom of the PC) should be
no more than the rated operating environment temperature of the PC;
7. At any point in the heat exchange area, the air flow speed should not be lower than
0.2m/s.
Picture 1 Largest dimensions of the PC
Picture 2 Heat exchange area