![Evo-lite TRAX TX1-24-SCW Series Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/evo-lite/trax-tx1-24-scw-series/trax-tx1-24-scw-series_instruction-manual_2446389004.webp)
•
•
• ©2020 EVO-LITE, LLC • 6240 W 54TH AVE., ARVADA, CO 80002 • V1–4420
TEST BEFORE
INSTALLING
Our production, packaging and shipping process is accompanied by rigorous quality control procedure.
All TRAX Arrays are subjected to a burn in period and are tested before packaging to ensure operation
of the highest quality. Due to possible unforeseen issues with shipping and handling, we advise that
all TRAX products be inspected at time of delivery and dry-fit tested for proper illumination prior to
mounting and again before the forward facing material is installed.
PRODUCT HANDLING, INSTALLATION & INTEGRATION ADVISORY
INSTALLATION
TEMPERATURE
Due to the characteristics of the adhesive backing present on TRAX Array’s wire clips, installation
environments and locations should be taken into consideration. Low temperatures can cause longer
cure times for permanent adhesion. The adhesive backing is not a permanent mounting solution.
Always use mechanical fasteners.
STORAGE
Store TRAX products in a clean, dry area on a flat, horizontal surface. Do not open the anti-static bag
until ready to install. Ideal storage conditions: Temperature of 68° – 77° F, 50% humidity.
STORAGE
DO NOT CONNECT
TO AC POWER
ANY DIRECT CONNECTION OF TRAX TO AC CURRENT WILL DAMAGE THE LEDs.
Be sure to use a UL
Listed or UL Recognized Class 2, LPS or LVLE low voltage power supply that conforms to the voltage
requirements of the TRAX product. This information can be found on the TRAX spec sheet and its
packaging, as well as the power supply labeling.
Evo-Lite’s experience in providing backlighting solutions yields a unique perspective on the characteristics and underlying intuitive knowledge necessary to
complete a successful installation of TRAX. Evo-Lite is committed to educating and supporting all our customers so every installation proceeds as smoothly
as possible. Most installations offer their own unique challenges. We hope by making you aware of the following handling and installation guidelines you
are empowered with knowledge for a successful installation. As always, Evo-Lite is ready to assist you with any questions that arise during your installation.
TRAX has an advanced 5-year warranty. Please review section 19 of Terms & Conditions of Sale at www.evo-lite.com/legal-documents/#TermsSale
SNAPPING
LED BARS
DISCONNECT POWER AT THE SOURCE BEFORE ALTERING TRAX IN ANY WAY.
NEVER CUT OR SNAP
TRAX WHILE POWERED.
Field snapping and cutting of TRAX does not void UL Listing. LEDs can lose
input power if snap lines are not followed. Avoid cut edge contact with any conductive material(s),
including other cut edges of TRAX Arrays. See also Wet Location Use below.
SOLDERING
DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE PRODUCT IN ANY WAY.
The unique
power grid of TRAX prevents the need for soldering in most cases. The LED bar’s copper pads are
engineered to handle 4A of load and polarity is noted by the + and - next to each copper pad. Use 18
AWG stranded copper wire for up to 4A of load and follow electronics soldering best practices.
FASTENING
USE PAN HEAD, DOMED, ROUND HEAD FASTENERS, OR TAPERED SCREWS.
Never screw the fastener
so much that it deforms TRAX or its components. Fastening only takes place through the mounting
holes on wire clips, Standard / Deep Bar Retention Clips, Rail End Mounting Clips, or Rail Mounting
Clips. For suspended applications, use mechanical fasteners with appropriate spacing to avoid sagging
or use the TRAX Rail Mounting Kit.
WET LOCATION
USE
TRAX is IP65 rated. This rating is total protection against dust ingress as well as water projected by a
nozzle against the enclosure from any direction for a limited time and may be used in wet locations, but
not where standing water can accumulate. Cut edges of IP65 can optionally be sealed from moisture
with an RTV Silicone Sealant or conformal coating.
IP65
POWER, CONTROL
& WIRING
For optimal power distribution and to minimize voltage drop, it is recommended that multi-strand, high
strand count wiring be used for all low voltage DC connections. Wire gauge should be appropriate based
upon system voltage and wire lengths to further minimize voltage drop. Power supplies, drivers and
controls should be installed in well ventilated enclosures and/or per manufacturers recommendations.
It is the customer’s responsibility to ensure all components and installation practices meet or exceed
local codes and requirements.
DO NOT OVER-
BEND LED BARS
The LED bars on TRAX offer limited flexibility. In some circumstances a very slight bend to the bars may
be desired and implemented. Consult with your Evo-Lite Systems Integration Specialist to see if there
may be a better product for your application.
PRE-INSTALLATION
Before mounting, unroll TRAX and pull ends apart so that the TRAX Array is taught. This will help take
out the bends and kinks in the wire so that the intended bar-to-bar spacing is realized.
DO NOT DRILL
Do not drill through TRAX LED bars. It will result in damage to the LEDs and denial of any warranty claims.
Use the wire clip’s’ mounting holes to attach the bars to a mounting surface as depicted on page 3,
Step 2 // Fasten To Surface. Use fasteners that are appropriate for the mounting surface.