TEST BEFORE 

INSTALLING

Our production, packaging and shipping process is accompanied by rigorous quality control procedure. 

All TRAX Arrays are subjected to a burn in period and are tested before packaging to ensure operation 

of the highest quality. Due to possible unforeseen issues with shipping and handling, we advise that 

all TRAX products be inspected at time of delivery and dry-fit tested for proper illumination prior to 

mounting and again before the forward facing material is installed. 

PRODUCT HANDLING, INSTALLATION & INTEGRATION ADVISORY

INSTALLATION 

TEMPERATURE 

Due  to  the  characteristics  of  the  adhesive  backing  present  on  TRAX  Array’s  wire  clips,  installation 

environments and locations should be taken into consideration. Low temperatures can cause longer 

cure  times  for  permanent  adhesion.  The  adhesive  backing  is  not  a  permanent  mounting  solution. 

Always use mechanical fasteners.

STORAGE

Store TRAX products in a clean, dry area on a flat, horizontal surface. Do not open the anti-static bag 

until ready to install. Ideal storage conditions: Temperature of 68° – 77° F, 50% humidity.

STORAGE

DO NOT CONNECT 

TO AC POWER

ANY DIRECT CONNECTION OF TRAX TO AC CURRENT WILL DAMAGE THE LEDs. 

Be sure to use a UL 

Listed or UL Recognized Class 2, LPS or LVLE low voltage power supply that conforms to the voltage 

requirements  of  the  TRAX  product.  This  information  can  be  found  on  the  TRAX  spec  sheet  and  its 

packaging, as well as the power supply labeling.

Evo-Lite’s experience in providing backlighting solutions yields a unique perspective on the characteristics and underlying intuitive knowledge necessary to 

complete a successful installation of TRAX. Evo-Lite is committed to educating and supporting all our customers so every installation proceeds as smoothly 

as possible. Most installations offer their own unique challenges. We hope by making you aware of the following handling and installation guidelines you 

are empowered with knowledge for a successful installation. As always, Evo-Lite is ready to assist you with any questions that arise during your installation.

TRAX has an advanced 5-year warranty. Please review section 19 of Terms & Conditions of Sale at www.evo-lite.com/legal-documents/#TermsSale

SNAPPING 

LED BARS

DISCONNECT POWER AT THE SOURCE BEFORE ALTERING TRAX IN ANY WAY.

 

NEVER CUT OR SNAP 

TRAX WHILE POWERED.

 Field snapping and cutting of TRAX does not void UL Listing. LEDs can lose 

input power if snap lines are not followed. Avoid cut edge contact with any conductive material(s), 

including other cut edges of TRAX Arrays. See also Wet Location Use below.

SOLDERING

DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE PRODUCT IN ANY WAY. 

The unique 

power grid of TRAX prevents the need for soldering in most cases. The LED bar’s copper pads are 

engineered to handle 4A of load and polarity is noted by the + and - next to each copper pad. Use 18 

AWG stranded copper wire for up to 4A of load and follow electronics soldering best practices. 

FASTENING

USE PAN HEAD, DOMED, ROUND HEAD FASTENERS, OR TAPERED SCREWS. 

Never screw the fastener 

so much that it deforms TRAX or its components. Fastening only takes place through the mounting 

holes on wire clips, Standard / Deep Bar Retention Clips, Rail End Mounting Clips, or Rail Mounting 

Clips. For suspended applications, use mechanical fasteners with appropriate spacing to avoid sagging 

or use the TRAX Rail Mounting Kit.

WET LOCATION 

USE

TRAX is IP65 rated. This rating is total protection against dust ingress as well as water projected by a 

nozzle against the enclosure from any direction for a limited time and may be used in wet locations, but 

not where standing water can accumulate. Cut edges of IP65 can optionally be sealed from moisture 

with an RTV Silicone Sealant or conformal coating.

IP65

POWER, CONTROL 

& WIRING

For optimal power distribution and to minimize voltage drop, it is recommended that multi-strand, high 

strand count wiring be used for all low voltage DC connections. Wire gauge should be appropriate based 

upon system voltage and wire lengths to further minimize voltage drop. Power supplies, drivers and 

controls should be installed in well ventilated enclosures and/or per manufacturers recommendations. 

It is the customer’s responsibility to ensure all components and installation practices meet or exceed 

local codes and requirements.

DO NOT OVER-

BEND LED BARS

The LED bars on TRAX offer limited flexibility. In some circumstances a very slight bend to the bars may 

be desired and implemented. Consult with your Evo-Lite Systems Integration Specialist to see if there 

may be a better product for your application.

PRE-INSTALLATION

Before mounting, unroll TRAX and pull ends apart so that the TRAX Array is taught. This will help take 

out the bends and kinks in the wire so that the intended bar-to-bar spacing is realized.

DO NOT DRILL

Do not drill through TRAX LED bars. It will result in damage to the LEDs and denial of any warranty claims. 

Use the wire clip’s’ mounting holes to attach the bars to a mounting surface as depicted on page 3,  

Step 2 // Fasten To Surface. Use fasteners that are appropriate for the mounting surface.

Содержание TRAX TX1-24-SCW Series

Страница 1: ...an be used in wet locations but not where water may accumulate Do not penetrate the TRAX LED bar with any type of mechanical fastener Only use mechanical fasteners in the established marked locations See page 3 MOUNTING TRAX for more details LEDs are bright Do not look directly at lighted product Dry fit TRAX Array and power connections before permanently installing to a substrate Always test oper...

Страница 2: ...lude allowing headroom for power supply longevity The TRAX system s integrated bar to wire connectors have a 4A capacity Do not exceed the load capacity of these connection blocks in any configuration The TRAX Array may be powered from any of the four wire leads Choose the best wire lead according to power supply location Do not exceed the 4A maximum load capacity in any configuration Use the incl...

Страница 3: ...rd Bar Retention Clips sold separately TX1 BRC STD 10 to provide additional LED Bar support Step 1 Assemble The Rails Assemble the Rail Mounting Kit Rails A using the kit s included Rail To Rail Connectors B and End Mounting Clips D These pieces slide and click into place no tools required Rails may be cut to size Step 2 Prepare Mounting Location Mark the desired location for Rails A The correct d...

Страница 4: ...can lose input power if snap lines are not followed Avoid cut edge contact with any conductive material s including other cut edges of TRAX Arrays See also Wet Location Use below SOLDERING DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE PRODUCT IN ANY WAY The unique power grid of TRAX prevents the need for soldering in most cases The LED bar s copper pads are engineered to handle 4A of load and...

Отзывы: