Evo-lite TRAX TX1-24-RGBW Series Скачать руководство пользователя страница 1

WWW.EVO-LITE.COM

   

• 

  

[email protected] 

  •  

 

1-888-887-2980 

 

 •   ©2021 EVO-LITE, LLC  •  6240 W 54TH AVE., ARVADA, CO 80002  •  V2–3221

INSTRUCTION MANUAL

 BACKLIGHTING // RETICULAR LED SYSTEMS // TRAX // RGBW

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION

RETICULAR BACKLIGHTING SYSTEM | RGBW

ITEM #: TX1-24-RGBW SERIES (RED, GREEN, BLUE, WHITE)

CONTENTS

Each TRAX RGBW package includes one TRAX Array (A) and  

five Wago connectors (B).

PART

PRODUCT DESCRIPTION 

QTY

A

TRAX Array (24” x 96” / 609.6mm x 2438.4mm) with 64 LED bars each pre-
wired and pre-mounted to wire mounting clips

1

B

Wago same polarity, two port splicing connectors

5

ELECTRICAL

Input Voltage

24 Volt DC – Constant Voltage

Input Power

86W per TRAX Array, 1.34W per bar, 0.021W per LED

Connectivity

One TRAX Array to retain Class 2 compliance per UL regulations

Certification

IP65, cULus Listed (E495221), CE Compliant (EMC and LVD), and RoHS Certified

PHYSICAL

Cut Line Spacing

Snappable segments every 0.75” (19mm)

Coverage

Up to 16ft

2

 (1.486m

2

) per Class 2 guidelines, 0.098ft

2

 (0.009m

2

) per bar

Operating Temp.

-22°F ~ +158° F (-30C ~ +70C)

POWER & CONTROLS

Compatible with full range (100% – 0%), flicker-free power and control components.

Please contact Evo-Lite for optimal solutions to fit your requirements.

B WAGO CONNECTORS

W

W

B

B

G

G

R

R

W

B

G

R

W

B

G

R

W

B

G

R

TX1-24-RGBW

WWW.EVO-LITE.COM

TX1-24-RGBW

WWW.EVO-LITE.COM

TX1-24-RGBW

WWW.EVO-LITE.COM

TX1-24-RGBW

WWW.EVO-LITE.COM

TX1-24-RGBW

WWW.EVO-LITE.COM

TX1-24-RGBW

WWW.EVO-LITE.COM

TX1-24-RGBW

TX1-24-RGBW

WWW.EVO-LITE.COM

WWW.EVO-LITE.COM

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

W

B

G

R

PROFILES 

(SEE SPEC SHEET FOR MORE DETAILS)

0.0625” 

(1.6mm)

0.313” 

(8mm)

Wire Clip

Wire Clip

LED Bar

24” (609.6mm)

BEST PRACTICES

HANDLING ADVISORY & PRE-INSTALL TESTING

//  WARNING: RISK OF ELECTRIC SHOCK. Disconnect power at the source before snapping, cutting, or altering product in any way. Do not connect TRAX 

to AC current. Use only with 24V DC input power.

//  To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this manual and stay within its guidelines when using this product. 

Save these instructions for future reference. Read and follow the product handling, installation, & integration advisory on page 4.

// Product should be installed in accordance with local/regional electrical codes and the current National Electric Code (NEC).
// Product must be installed per instructions and contained within and exclusive to application where not subject to damage.
//  Use only with UL Listed or UL Recognized Class 2, Limited Power Source (LPS) or Low Voltage Limited Energy (LVLE) power supplies. Provide the 

appropriate number of 24V Class 2 circuits for your layout. Do not exceed the maximum load limit of any power supply per the manufacturer’s 

recommendations.

//  To retain Class 2 compliance per UL regulations, do not interconnect more than one full 24” x 96” (609.6mm x 2438.4mm) TRAX Array (86W). Use one 

96W 24V Class 2 LPS or LVLE power supply / channel per TRAX Array. Best practices include allowing headroom for power supply longevity. The TRAX 

system’s integrated wire clips have a 4A capacity. Do not exceed the load capacity of these in any configuration.

// This product is rated IP65 and can be used in wet locations, but not where water may accumulate.
//  Do not penetrate the TRAX LED bar with any type of mechanical fastener. Only use mechanical fasteners in the established, marked locations. See 

page 3 - MOUNTING TRAX for more details.

// LEDs are bright. Do not look directly at lighted product.

//  Dry fit TRAX Array and power connections before permanently installing 

to  a  substrate.  Always  test  operation  before  installing  the  translucent 

(forward-facing) material.

//  When  not  working  with  curved  applications,  the  Rail  Mounting  Kit  (sold 

separately: TX1-M-RMK) is strongly recommended. The Rail Mounting Kit 

will reduce installation time and labor while improving accuracy. 

//  Never slide heavy materials over product as this may cause damage to the 

lighting product or material.

// Avoid installing where subject to continuous flexing.

// For detailed, application specific installation guidance, please contact us.

TRAX ARRAY

A

Do not set anything on top of the product (i.e. tools, mugs, etc.). 

Avoid placing product on floor or anywhere it could be stepped 

on. The product may be damaged with improper handling.

Due to possible unforeseen issues with shipping and handling, 

we advise that all products be inspected at time of delivery and 

dry-fit  tested  for  proper  illumination  prior  to  mounting  and 

again before the forward-facing material is installed.

For troubleshooting guidance, please visit www.evo-lite.com

24V

IP65

DIMMABLE

+

SAFETY & COMPLIANCE INFORMATION

Read all instructions before beginning.

SPECIFICATIONS

Содержание TRAX TX1-24-RGBW Series

Страница 1: ...installed in accordance with local regional electrical codes and the current National Electric Code NEC Product must be installed per instructions and contained within and exclusive to application where not subject to damage Use only with UL Listed or UL Recognized Class 2 Limited Power Source LPS or Low Voltage Limited Energy LVLE power supplies Provide the appropriate number of 24V Class 2 circu...

Страница 2: ... find the closest snap line Pinch the LED bar on both sides of the snap line Then apply slight pressure with both thumbs until the bar snaps apart figure 2 TRAX may be cut to length by cutting the wires anywhere between the wire mounting clips Cuts may be made to one or both columns of wires figure 3 STANDARD BAR RETENTION CLIPS A POWER LINK CABLE D CENTIPEDE CABLE E DEEP BAR RETENTION CLIPS B RAI...

Страница 3: ...ugh wire clip s mounting holes Step 3 Secure All Wire Clips Repeat the previous steps to secure all wire clips to mounting surface ensuring the TRAX Array is taut with LED Bars laying flat Step 4 Add Support As Needed If needed use Standard Bar Retention Clips sold separately TX1 BRC STD 15 to provide additional LED Bar support Step 1 Assemble The Rails Assemble the Rail Mounting Kit Rails A using...

Страница 4: ...can lose input power if snap lines are not followed Avoid cut edge contact with any conductive material s including other cut edges of TRAX Arrays See also Wet Location Use below SOLDERING DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE PRODUCT IN ANY WAY The unique power grid of TRAX prevents the need for soldering in most cases The LED bar s copper pads are engineered to handle 4A of load and...

Отзывы: