3600 Lind Ave SW, Suite 140, Renton, WA 98057 425-336-5800 www.evluma.com
Fixture Requirements
Input Voltage:
120–277VAC
Frequency:
50/60Hz
Socket Base:
E26 (medium) or E39 (mogul)
Fixture Minimum
Inside Dimensions:
7.0”H x 4.0”W (medium base)
8.5”H x 4.0”W (mogul base)
Orientation:
Lamp can be mounted in any static orientation.
Photocontrols:
If the socket is controlled by a photocontrol, it must be of a “Fail ON”
type for the OmniMax Photocontrol Failsafe™ feature to operate.
Operating Ambient
Temperature:
-40°C - +40°C
SUITABLE FOR DAMP LOCATIONS.
DAPTÉ POUR ENDROITS HUMIDES.
Retrofit Kit Contents
(1) LED retrofit lamp
(1) E39 mogul adapter
(1) Fixture label
(1) Installation guide
Applicable Products
OMNI-40-2K-ME 40W 2000K OMNI-70-2K-ME
70W 2000K
OMNI-40-3K-ME 40W 3000K OMNI-70-3K-ME
70W 3000K
OMNI-40-4K-ME 40W 4000K OMNI-70-4K-ME
70W 4000K
OMNI-40-5K-ME 40W 5000K OMNI-70-5K-ME
70W 5000K
This device complies with Part 15 of FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
This product is intended to be installed in outdoor, ballast-based HID luminaire that have been appropriately modified.
The following fixtures are representative examples of the types of fixtures appropriate for OmniMax.
Acorn & Globe types:
King K400 Series, Lexalite Lindy Model 424, GE Patriarch, Holophane GV Washington PostLite
Lantern types:
Architectural Area Lighting Civic Lantern Series, Acuity Lighting TR25
Teardrop & Bullet types:
Holophane Port Huron, HE Williams OGL Series, Acuity Lighting (Antique Street Lamps) CM
100293-001 REV A02
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
WARNING
- Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire
electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
WARNING
- When installing LED retrofit lamps within HID fixtures, ballast must be bypassed
when present.
WARNING
- To avoid electric shock or component damage, disconnect power before attempting
installation or servicing.
WARNING
- Do not make or alter any open holes in an enclosure of wiring or electrical
components during kit installation.
WARNING
- To prevent wiring damage or abrasion, do not expose wiring to sharp edges of
housing or other sharp surface.
OMNI 40
OMNI 70
EVLUMA OMNIMAX
TM
INSTALLATION GUIDE
LED DECORATIVE LUMINAIRE RETROFIT
40W or 70W REPLACES HID BULBS 100-175W