System Faults
System faults are generated by the outboard and the remote control. When an active or
current fault is broadcast on the network by a remote control or outboard, the display will:
1. Take no action unless the display is in Diagnostic or System mode. In those instances,
the faults will be displayed.
2. Indicate an existing warning by highlighting an outboard status indicator icon on the
Status Bar.
3. Initiate a Pop-up with the appropriate information displayed. The Pop-up color will be
orange. In addition, the appropriate Outboard Status Indicator in the Status Bar will be
highlighted.
4. Initiate a Pop-up with the appropriate information displayed. In addition, the Audible
Alarm Drive Output will be set to sound an audible user alert. The Pop-up color will be
red. In addition, the appropriate Outboard Status Indicator in the Status Bar will be
highlighted.
A Pop-up and audible warning will remain in effect until acknowledged by the operator by
touching the pop-up area. As long as the fault is active, the pop-up may be re-initiated by
touching the right-hand side of the Outboard Status Indicator area of the Status Bar.
Turning the Display ON
Turn the key switch to the ON position or start the outboard to turn the display ON.
Troubleshooting Tip
Problem
Solution
Display does not power on
Charge the network power
supply battery to a minimum
of 12.5V.
Disconnect wiring harness
from back of gauge, and then
securely reconnect it
.
Select if highlighted to open a Pop-up warning