29
O
PERATION
HIGH ALTITUDE
Your outboard’s
EMM will automatically com-
pensate for changes in altitude. However, if
you boat above 3000 ft. (900 m), you will ex-
perience a slight loss of power due to reduced
air density.
If your engine drops below the recommended
RPM operating range at full throttle, have your
Dealer select a lower pitch propeller.
If you return to sea level, have your Dealer in-
stall the original propeller and verify correct
RPM operating range.
FREEZING WEATHER
IMPORTANT:
Use
Evinrude/Johnson XD100
oil when operating your
Evinrude E-TEC out-
board in freezing weather. Refer to
During operation in freezing weather, keep
the gearcase submerged at all times.
Upon removing your outboard from the water,
leave it in a vertical position until its cooling
system is drained.
IMPORTANT:
Store the outboard vertically.
Water remaining in the gearcase, cooling sys-
tem or other components can freeze, causing
serious engine damage.
IMPORTANT:
If your outboard’s gearcase is
equipped with an integral speedometer pick-
up, all water must be cleared from the hose to
prevent gearcase damage. Refer to
SHALLOW WATER
IMPORTANT:
Gearcase damage can occur if
the gearcase is allowed to drag on the water-
way bottom.
DUAL OUTBOARD OPERATION
When in reverse above slow speed, be sure
both outboards are running, even if one is in
NEUTRAL.
If it is necessary to return to harbor with one
outboard not running, tilt the inoperative out-
board high enough to keep its propeller out of
the water.
UNDER TOW
Should you require a tow from another boat:
• Shift your engine to NEUTRAL;
• Tilt its gearcase out of the water;
• Off-load all persons into another boat; and
• Keep speed slower than planing speed.
FUSE
Fuse Replacement
IMPORTANT:
Use only fuses of the same rat-
ing. Your
Evinrude E-TEC outboard uses 10-
amp fuses.
Remove engine cover. Install spare fuse in
place of failed fuse.
1. Fuse
2. Spare fuse
IMPORTANT:
Failure to install cover securely
may cause electrical problems.
A blown fuse will not allow the engine to
crank. Replace it with a fuse of the same rat-
ing. A spare fuse is provided.
Repeated fuse failures indicate a potentially
serious problem. Do not replace it with higher
rated fuse; see your Dealer for service.
1
2
Содержание 2004 75 E-TEC
Страница 10: ......
Страница 11: ...9 USING YOUR EVINRUDE E TEC OUTBOARD USING YOUR E TEC OUTBOARD...
Страница 33: ...31 MAINTENANCE...
Страница 40: ...38 Maintenance OWNER S NOTES...
Страница 41: ...39 PRODUCT INFORMATION...
Страница 54: ...52 Product Information...
Страница 56: ...54 Product Information...
Страница 57: ...55 OWNER S NOTES...
Страница 60: ......