Operation introductions

1. Initialization 

 

On Start-up state, actual water in temperature displays on the right side, setting 

   

temperature displays on the

 side. Stand-by state only shows the actual testing

   

temperature on the right side.

 

On start-up state, the heating symbol        always displays, stand-by state do not display 

     

any heating symbol, but heating symbol       long flashing when heat pump is defrosting.

 

The background lightens up when pressing any key; disappear if no operation for 10 

   

seconds.

 left

2.  

Definition of LCD Controller Buttons.

2.1    "         "

for ON /OFF and Return 

2.1.1  

On main interface, Press 

         

 to turn on or turn off the heat pump.

2.1.2  

After entering parameter or clock setting, press 

        

 once to return to

          

 main interface.

Start-up state

 

Stand by state

 

1

2

Initialization

 

.Operation introductions

Water heater

2.2    "       "

for Status Inquiry 

2.2.1  

Press       once to check each actual temperature value or the open steps for 2 

          expansion valve.

2.2.2  

Long press        for 5 seconds to enter parameter setting.

2.3    "       "

"       "

for Up and Down 

2.3.1  

Under start-up state, press        

a nd 

      to directly adjust/set water IN 

           temperature ,setting range 

(20℃

-

80℃)

2.3.2  

Press        and        or

 

       to check or change the parameters or check 

           each temperature value or open step for electric expansion valve.

2.4    "        "

for Clock and Auxiliary Heater setting

2.4.1  

Press      

 

once to enter Clock setting, meanwhile press         or          to

           change the time.

2.4.2  

Long press        for 5 seconds to switch on or off the auxiliary heater 

           function . When auxiliary heater symbol         is displayed, system 

           allows to start the Auxiliary heater function.

6

Содержание SWBH-15.0H-B/P-S

Страница 1: ...Installation Instruction Manual EVI 80 C HEAT PUMP WATER HEATER MODEL SWBH 15 0H B P S...

Страница 2: ...customers Product Introducing 2 Work principle 3 Performance Data 4 Dimension 5 Operation introductions 6 Wire Circuit Diagram 11 Installation instructions 12 Maintenance 16 1 CONTENTS Water heater C...

Страница 3: ...ponents without switching off the electrical supply to the unit Electric leakage switch protection device MUST be installed 3 It is forbidden to start any work on the electrical components if water or...

Страница 4: ...Heat pump not only use less electricity to get heat from ambient air but are also able to combine using with solar equipment will not cause pollution and no poison gas exhausting All Round The Year Ho...

Страница 5: ...mpressor compress it the refrigerant gas became high temperature and high pressure Then the gas come into the water condensation into liquid emit a lot of condensation heat condensing heat absorbed by...

Страница 6: ...1300 500 1370 160 SWBH 15 0H B P S Model Rated heating capacity w Power supply V Ph Hz Input power kw heat up water heat up water Running current A Thermostat factory setting Thermostat maximum setti...

Страница 7: ...The dimension for air source heat pump water heater SWBH 15 0H B P S low ambient Dimension Water heater 5 Measure mm 1300 765 420 1370 460 500...

Страница 8: ...k setting press once to return to main interface Start up state Stand by state 1 2 Initialization Operation introductions Water heater 2 2 for Status Inquiry 2 2 1 Press once to check each actual temp...

Страница 9: ...ame time for 3 seconds to lock or unlock the keyboard Clock setting 3 3 Clock Setting 3 3 1 On main interface press once to enter clock setting interface 3 3 2 press or to change the clock setting Pre...

Страница 10: ...one to confirm setting 3 5 Press both and at the same time for 5 seconds to enter force defrost heating symbol long flashes On enquiry state stop operation within for 10 seconds to return to main inte...

Страница 11: ...e protect temperature memory Maximum Water Inlet temp Minimum Water Inlet temp Setting range 20 80 1 12 15 90 MIN 1 20 30 0 1 30 30 90 MIN 1 12 MIN 0 1 10 48 F F 0 1 10 48 F F 100 125 0 1 60 80 20 40...

Страница 12: ...When 5 C ambient temp 15 C Set point temp Data of Parameter 16 Data of parameter 16 data of parameter of 17 15 5 Ambient temp 5 For example when ambient temp is 18 deg c Parameter 16 data is 60 deg c...

Страница 13: ...OUT2 OUT3 OUT4 OUT7 OUT5 OUT8 OUT6 OUT9 5 5 Electronic Expansion Valve 1 Electronic Expansion Valve 2 CONTACTOR 1 CONTACTOR 2 CONTACTOR 3 6 5 4 3 2 1 FM1 PM FM2 Fan Motor T1 P1 T2 P2 T3 P3 T4 P4 T5 P5...

Страница 14: ...to the distance between the barriers shown in below picture pay attention to arrow direction Water tank 1Water tanks should be placed where ambient temperature is above 0 1Can be installed outdoors or...

Страница 15: ...llation 1All the pipeline tubing should be matched as shown on the manual and in accordance with national corresponding construction standards 1Installation of water pipes should be straight and flat...

Страница 16: ...eters valves water flow switch are safe and correct 1Check if having opened all the valves that should be opened and having closed all valves that should be closed 1Check if all necessary attemperator...

Страница 17: ...least 2 minutes 1 When water pump is on and the high level switch cut off if water temperature set Temperature 5 degrees shut down water supply for tanks If water tank temperature temperature 2 degree...

Страница 18: ...around should remain clean well ventilated Regularly clean 1 2 month the side air heat exchanger to maintain a good effect of heat exchange 7 Frequently check whether each part of the unit work normal...

Страница 19: ...EVI 80 C Heat Pump Water Heater...

Отзывы: