Everynet CloudCell 4G Скачать руководство пользователя страница 5

Warranty

ɉ

part 3

ɉ

Limited Warranty

ɉ

Everynet, B.V. (“EVERYNET”) warrants that the product(s) furnished hereunder (the “Product(s)”)

b

shall be free from defects in material and workmanship for a period of one (1) year from the date of

b

shipment by EVERYNET under normal use and operation. EVERYNET sole and exclusive obligation

b

and liability under the foregoing warranty shall be for EVERYNET, at its discretion, to repair or

b

replace any Product that fails to conform to the above warranty during the above warranty period.

b

The expense of removal and reinstallation of any Product is not included in this warranty. The

b

warranty period of any repaired or replaced Product shall not extend beyond its original term.

b

Warranty Conditions

ɉ

The above warranty does not apply if the Product:

b

Has been modified and/or altered, or an addition made thereto, except by EVERYNET, or

b

EVERYNET’ authorized representatives, or as approved by EVERYNET in writing;

b

Has been painted, rebranded or physically modified in any way;

b

Has been damaged due to errors or defects in cabling;

b

Has been subjected to misuse, abuse, negligence, abnormal physical, electromagnetic or electrical

b

stress, including lightning strikes, or accident;

b

Has been damaged as a result of using third party firmware;

b

Has no original EVERYNET label, or is missing any other original EVERYNET label(s); or

b

Has not been received by EVERYNET within 30 days of issuance of the RMA.

b

In addition, the above warranty shall apply only if: the product has been properly installed and

b

used

bb

At all times in accordance, and in all material respects, with the applicable Product

b

documentation; all outdoor installation cabling runs use braided, shielded and grounded Ethernet

b

CAT5 (or above), and for indoor installations, indoor cabling requirements are followed.

b

Returns

ɉ

No Products will be accepted for replacement or repair without obtaining a Return Materials

b

Authorization (RMA) number from EVERYNET during the warranty period, and the Products being

b

received at EVERYNET facility freight prepaid in accordance with the RMA process of EVERYNET.

b

Products returned without an RMA number will not be processed and will be returned freight collect

b

or subject to disposal.

bb

Disclaimer

ɉ

EXCEPT FOR ANY EXPRESS WARRANTIES PROVIDED HEREIN, EVERYNET, ITS AFFILIATES AND

b

ITS AND THEIR THIRD PARTY DATA, SERVICE, SOFTWARE AND HARDWARE PROVIDERS

b

HEREBY DISCLAIM AND MAKE NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND,

b

everynet.com

5

ɉ

Содержание CloudCell 4G

Страница 1: ...b b b CloudCell 4Gb b Installation manualb b b b...

Страница 2: ...y Paula Araujo IT Project and Process Managerb Alexey Shorokhovb Industrial Designerb Reviewed by Tim Kipleyb Infrastructure directorb Vitaly Klebanb CTOb Slava Vitykb Hardware engineerb b b b b every...

Страница 3: ...g 10b 4 10 Recommended equipment 11b Preparing the Gateway and cabling the network part 5 13b 5 1 Connectors specification 13b 5 2 Grounding 14b 5 3 Mount Antenna 14b 5 4 Mount Gateway 16b 5 5 Connect...

Страница 4: ...e use of the ground wire as a part of the safety certification b Modification or misuse may provide a shock hazard that could result in serious injury or death b Contact a qualified electrician or the...

Страница 5: ...etic or electricalb stress including lightning strikes or accident b Has been damaged as a result of using third party firmware b Has no original EVERYNET label or is missing any other original EVERYN...

Страница 6: ...YS CANCELLATIONS DELIVERYb FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGEb RESULTING FROM ANY OF THE FOREGOING In addition EVERYNET does not warrant that theb operation of the Produ...

Страница 7: ...ANb b b 4 2 Outdoor Omnidirectional Antenna LoRa antenna must meet these minimumb specificationsb b 50 Ohm N female connectorb 868 MHz or 915 MHz frequency range b Please select frequency range depend...

Страница 8: ...on antenna sideb N female on equipment sideb 0 4dB max insertion lossb DC 2GHz operation rangeb 90V breakdown voltageb 30W max input powerb 40 to 85 C temperature rangeb b 4 5 Two Micro SIM cards Plea...

Страница 9: ...ding straps requiredb b b 4 7 Butyl mastic tape 3M Butyl Mastic Tape 2212 3M IDb 7000133439b b b 4 8 Clamps and cable ties Antenna mounting clampsb Use only manufacturer approved mountingb brackets to...

Страница 10: ...atedb 50 pound testb b 4 9 Ethernet cabling Ubiquiti TOUGHcable PRO Carrierb Outdoor use CAT5eb UV protectedb 24 AWGb Braided shieldb Foil Shieldb Ground wireb b Grounded ethernet connector PoE side b...

Страница 11: ...3 pin grounded power cord for PoEb powerb b NOTE Verify with continuity meter that earthb grounding pin of PoE power cable isb continuous thru the power cord b b b 4 10 Recommended equipment Wire str...

Страница 12: ...Cat5 cable testerb b b b everynet com 12...

Страница 13: ...Preparing the Gateway and cabling the network part 5 5 1 Connectors specification 1 LoRa radio cableb 2 SIM cards holders USB resetb 3 Ethernet cableb b everynet com 13...

Страница 14: ...nt for protection against lightning strikes and dissipation of static electricity in the cables and equipment Please see drawing below for grounding diagram b 5 3 Mount Antenna Install the clamps that...

Страница 15: ...ng strap to towerb grounding pointb Connect lightning arrestor to antennab Hand tighten RF cable into the antennab NOTE Do not use a wrench or pliers as thisb will damage the gateway or connector b Ti...

Страница 16: ...ling tape b Two zip tie wraps shall be used for top andb bottom of sealing area one at top and one atb bottom of connector b b b b Verify weatherproofing on all cableb connectionsb b 5 4 Mount Gateway...

Страница 17: ...b b Mount gateway on the tower pole Tightenb steel ring clampsbb b everynet com 17...

Страница 18: ...nectb opposite end to the grounding point of theb tower b b Penetrox or anti oxidation agent must beb used when attaching grounding strap tob tower grounding pointb IMPORTANT It is not permitted to gr...

Страница 19: ...the gateway and connector b Tightening of RF connectors must be made byb handb b b b Completely wrap all RF cable connectionsb and N connectors with 3M Mastic Tape thenb at least two layers of Super 3...

Страница 20: ...eway Use only plastic ties b b b 5 6 Ethernet to gateway cable connection Insert the CONEC housing over the ethernetb cableb b Etch 4 cm of PVC cover with the wireb stripper Carefully remove the braid...

Страница 21: ...Orangeb b White Greenb b Blueb b White Blueb b Greenb b White Brownb b Brownb b b Place the wires in the correct order leaveb half the foil to connect the shield to the plug b Insert the wires carefu...

Страница 22: ...Insert connector into the CONEC housingb and screw nut b b everynet com 22...

Страница 23: ...b Fix the network cable in the tower with cableb ties model 35 56cm every 2 metersb b b b 5 7 Ethernet to PoE adapter cable connection Use TC GND for PoE injector side ofb ethernet cableb b Etch 4 cm...

Страница 24: ...b Orangeb b White Greenb b Blueb b White Blueb b Greenb b White Brownb b Brownb b b Place the wires in the correct order b leave half the foil to connect theb shield to the plug b Insert the wires ca...

Страница 25: ...h cable mapb tool and continuity testerb b Connect network cable POE port ofb PoE Ubiquiti PoE 48v 24w injectorb b Connect ethernet round wire to theb tower according to the scheme b Connect PoE power...

Страница 26: ...et b Ethernet cable shield MUST also beb grounded through the AC ground pin ofb the PoE power cable b 5 8 Verify all the connectors are correct b 5 9 Check LEDs indication Check that the connecting li...

Страница 27: ...5 10 Verify gateway is affixed securely on the tower b everynet com 27...

Страница 28: ...and can radiate radio frequency energyb and if not installed and used in accordance with the instructions b may cause harmful interference to radio communications bb However there is no guarantee that...

Отзывы: