Everwin SN65Q Скачать руководство пользователя страница 15

EYE PROTECTION

Which conforms to ANSI/ CE specifications and provides protection against flying particles both from 
the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when 
connecting to air supply, loading, operating, or servicing this tool. Eye protection is required to guard 
against flying fasteners and debris, which could cause severe eye injury. The employer and/or user must 
ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements 
of the ANSI Z87.1 and 89/686/EEC, and provide both frontal and side protection.

BEFORE HANDLING OR OPERATING THIS TOOL

Read and understand the warnings contained in this manual.

Refer to “tool specifications” in this manual to identify the operating system on your tool.

OPERATION : 

TOOL OPERATION SYSTEM

NOTE

Non-side shielded spectacles and face shields alone do not provide adequate protection.

There are two available systems in this tools :

1. Contact Trip Operation 

(available system on : SN65Q-CT, SN65S5-CT)

 

The CONTACT TRIP MODEL tool contains a contact trip that operates in conjunction with the trigger to drive a fastener. To 
operate the tool in this manner, hold the tool with the contact trip pointing towards but not touching the work surface. Pull 
the trigger and then tap the contact trip against the work surface using a bouncing motion. Each depression of the contact 
trip will cause a fastener to be driven.

2. Sequential Trip

 

Operation

 

(available system on : SN65Q-ST, SN65S5-ST)

 

 

The SEQUENTIAL TRIP MODEL contains a contact trip that operates in conjunction with the trigger to drive a fastener. 
To operate a sequential trip tool, first position the contact trip on the work surface WITHOUT PULLING THE TRIGGER. 
Depress the contact trip and then pull the trigger to drive a fastener. As long as the contact trip is contacting the work and 
is held depressed, the tool will drive a fastener each time the trigger is depressed. If the contact trip is allowed to leave the 
work surface, the sequence described above must be repeated to drive another fastener.

The operator must not hold the trigger on contact trip tools except during fastening operation, as serious injury could result 
if the trip accidentally contacts someone or something, causing the tool to cycle.

Keep hands and body away from the discharge area of the tool. A contact trip tool may bounce from the recoil of driving a 
fastener and an unwanted second fastener may be driven, causing injury.

WARNING  

WARNING  

15

Содержание SN65Q

Страница 1: ...65S5 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE...

Страница 2: ...d high volume fastening This tool delivers efficient and dependable service when used correctly with care As with any fine power tool the manufacturer s instructions must be followed for best performa...

Страница 3: ...coverage is limited to 90 days due to high volume usage warranty on production tools cannot be guaranteed due to unpredictable circumstances Tools are subjected to abuse such as hammering or usage of...

Страница 4: ...t ten tuotteen vastaavan seuraavla standardeja ja direktiivej 2006 42 EC ja EN ISO 11148 13 2018 CE Dichiarazione di conformit EVERWIN PNEUMATIC CORP dichiara assumendo la piena responsabilit che ques...

Страница 5: ...nsure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the emplo...

Страница 6: ...f the arm is not working correctly as accidental driving of a fastener may result Do not interfere with the proper operation of the contact arm mechanism Do not drive fasteners on top of other fastene...

Страница 7: ...and appropriate gloves and protective clothing are recommended Appropriate hearing protection shall be worn Use the correct energy supply as directed in the manual To drive fasteners into hard surface...

Страница 8: ...pain throbbing aching tingling numbness burning sensation or stiffness do not ignore these warning signs The operator should consult a qualified health professional regarding overall activities Disco...

Страница 9: ...3 6 2 9 kgs 6 4 lbs 2 9 kgs 6 4 lbs 3 08 liter second 6 5 cfm 3 08 liter second 6 5 cfm SPECIFICATIONS FASTENER SPECIFICATIONS TOOL AIR FITTING This tool uses a 3 8 19 P T 3 8 18 N P T male plug The i...

Страница 10: ...stem when using the tool will for example depend on the gripping force the contact pressure force the working direction the adjustment of mains supply and the workpiece support AIR CONSUMPTION 3 08 li...

Страница 11: ...p available system on SN65Q ST SN65S5 ST The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger This makes accurate fastener placement easier for instan...

Страница 12: ...l may fracture or burst causing injury OPERATING PRESSURE Do not exceed recommended maximum operating pressure as tool wear will be greatly increased The air supply must be capable of maintaining the...

Страница 13: ...ulting in poor tool performance and frequent tool maintenance If no air line lubricator is used add oil during use into the air fitting on the tool once or twice a day Only a few drops of oil at a tim...

Страница 14: ...EVENT ACCIDENTAL INJURIES Never place a hand or any other part of the body in the discharge area of tool while the air supply is connected Never point the tool at anyone else Never engage in horseplay...

Страница 15: ...te the tool in this manner hold the tool with the contact trip pointing towards but not touching the work surface Pull the trigger and then tap the contact trip against the work surface using a bounci...

Страница 16: ...eaks air or does not function properly Notify your distributor or representative if your tool continues to experience functional problems 1 Contact Trip Operation 2 Sequential Trip Operation a The too...

Страница 17: ...toward the nose to increase the drive of depth deep Tighten screw with 4mm hex key The DEPTH OF DRIVE ADJUSTMENT feature provides close control of the fastener drive depth from flush with the work su...

Страница 18: ...ME Air volume is as important as air pressure The air volume supplied to the tool may be inadequate because of undersize fittings and hoses or from the effects of dirt and water in the system Restrict...

Страница 19: ...from the air supply 2 Pull pusher into its pusher lock position as shown remove staples from the magazine 3 Open the jam clearing nose door by pulling down and then up on the latch 4 Remove the jammed...

Страница 20: ...20...