TOOL OPERATION CHECK 

 

CAUTION: Remove all fasteners from tool before performing tool operation check. 

 

1.  CONTACT TRIP OPERATION: 

 

a.  With finger off the trigger, press the contact trip against the work surface. 

THE TOOL MUST NOT CYCLE. 

 

b.  Hold the tool off the work surface, and pull the trigger. 

THE TOOL MUST NOT CYCLE.

 

c.  With  the  tool  off  the  work  surface,  pull  the  trigger.  Press  the  contact  trip  against  the  work 

surface. 

THE TOOL MUST CYCLE.

 

d.  Without touching the trigger, press the contact trip against the work surface, then pull the 

trigger. 

THE TOOL MUST CYCLE. 
 

2. 

SEQUENTIAL TRIP OPERATION:

 

 

a.  Press the contact trip against the work surface, without touching the trigger. 

THE TOOL MUST NOT CYCLE.

 

b.  Hold the tool off the work surface and pull the trigger.

 

THE TOOL MUST NOT CYCLE.

 

Release the trigger. The trigger must return to the trigger stop on the frame. 

c.  Pull the trigger and press the contact trip against the work surface. 

THE TOOL MUST NOT CYCLE.

 

d.  With finger off the trigger, press the contact trip against the work surface. Pull the trigger. 

THE TOOL MUST CYCLE. 

 

IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR 

SAFE OPERATION 
 

l

 

Use this pneumatic tool only for the purpose for which it was designed.

 

l

 

Never use this tool in a manner that could cause a fastener to be directed toward the user or others.

 

l

 

Do not use the tool as a hammer.

 

l

 

Always carry the tool by the handle. Never carry the tool by the air hose.

 

l

 

Do not carry this tool with the trigger depressed when not in use

l

 

Do not alter or modify this tool from the original design or function.

 

l

 

isuse and improper handling of this tool can cause injury to yourself and others.

 

l

 

Never clamp or tape the trigger or contact trip in an actuated position.

 

l

 

Never leave a tool unattended with the air hose attached.

 

l

 

Do not operate this tool if it does not contain a legible WARNING LABEL.

 

l

 

Do not continue to use a tool that leaks air or does not function properly. Notify your 
distributor or representative if your tool continues to experience functional problems.

 

 

 
 
 
 

Содержание FSN2283 Series

Страница 1: ...ANCE MANUAL CE DECLARATION OF CONFORMITY Everwin Pneumatic Corp 20 8 05 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INST...

Страница 2: ...itional safety measures may be required because of your particular application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use Everwin...

Страница 3: ...eals driver blades bumpers pistons and piston rings b Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenanc...

Страница 4: ...PNEUMATIC CORP declaramos bajo nuestra sola responsabilidad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelseserkl ring CE Dekl...

Страница 5: ...ed the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress con...

Страница 6: ...onnected from the air supply OPERATING PRESSURE 70 to 120 PSI 5 to 8 kg cm2 Select the operating pressure within this range for best fastener performance DO NOT EXCEED THIS RECOMMENDED OPERATING PRESS...

Страница 7: ...atic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally allowed to recontact the work surface with the trigger still actuated finger still...

Страница 8: ...n pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clea...

Страница 9: ...care l Do not pull the trigger or depress the trip mechanism while loading the tool LOADING THE TOOL Open the magazine Pull pusher back to engage the latch Nail loading Hold nailer down with magazine...

Страница 10: ...ng fastening operation as serious injury could result if the trip accidentally contacts someone or something causing the tool to cycle Keep hands and body away from the discharge area of the tool A co...

Страница 11: ...L MUST NOT CYCLE d With finger off the trigger press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE T...

Страница 12: ...re evaluating tool problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittings low points containing water and anything else that wou...