background image

Frame Manual 

500FR 3 Rack Unit Frame 

 Revision 

1.4 

500FR-1 

1. OVERVIEW 

The 500FR is a 3 rack unit high rack frame for the 500 series 

modular system.  This 

advanced rack frame design can house up to 16 of the 500 series distribution, conversion and processing 
modules in any combination.  Special care was taken during the design process to ensure that the 500FR 
meets the demanding needs of television studios today has sufficient flexibility to satisfy the emerging 
demands of the future. 
 
The 500FR is designed with a high density capacity to conserve on precious equipment rack space.  Care 
has been taken to ensure sufficient thermal relief for up to 120 watts of processing power per frame, to 
meet the increasing power demands of future high speed processing cards. 
 
Hot swappable redundant switching power supplies and cooling fans allow power supply or fan 
replacement without compromising the integrity of critical signal paths.   
 
The front loading design permits extraction of the power supplies and active modules from the front 
without compromising performance even at 1.5Gb/s.  Thus, there is no need for time consuming re-cabling 
nor is there need to have access to the rear of the frame replace or exchange modules. 
 
The Frame is available in different versions to suit a variety of applications.  Throughout this manual, 
references to 500FR refer to all models of the frame unless otherwise specified. 
 

Model  

Description 

500FR 

AC powered frame.  This frame supports all 500 series 
modules 

EXCEPT

 analog or digital loop through modules. 

500FR-L-A 

AC powered frame with loop thru capability for analog video 
signal.  This frame supports 

ONLY

 analog loop thru modules. 

500FR-L-D 

AC powered frame with loop thru capability for digital video 
signal.  This frame supports 

ONLY

 digital loop thru modules. 

 

Features: 

• 

Houses up to 16 processing modules.  Use 500FR-L versions for loop through modules. 

• 

Front monitoring window for verifying module and power supply status 

• 

Frame status contact closure alarm signals power supply or fan failures and user selectable 
module alarms 

• 

Front extractable modules, power supplies and fans  

• 

Auto-ranging power supply operates from 90-250vac at 60/50hz 

• 

Power supply and frame cooling fans are fully redundant and hot-swappable  

• 

High-speed bussing and control system provided for modular applications 

 

Additional Features (500FR-L-A and 500FR-L-D versions only) 

• 

Ability to provide a single input source to multiple loop thru modules in a single frame 

• 

Hot swapping of loop thru modules without impacting input signal to other loop thru modules 

• 

Supports up to 16 Analog loop thru modules (500FR-L-A only) 

• 

Supports up to 16 (SD) or 12 (HD) Digital loop thru modules (500FR-L-D only) 

 

Содержание exponent 500FR

Страница 1: ...2 FRAME STATUS FAULT CONDITIONS 5 2 1 FRAME STATUS TALLY TERMINAL BLOCK 5 3 INSTALLING AND REMOVING THE MODULES 5 3 1 OPENING AND CLOSING THE FRONT PANEL 5 3 2 INSTALLING THE MODULES 6 3 3 REMOVING THE MODULES 6 4 SERVICING INSTRUCTIONS 6 4 1 CHANGING THE FUSES 6 4 2 REPLACING THE POWER SUPPLY 6 Figures Figure 1 500PS Status Indicators 4 Figure 2 Locating the Power Supply Mounting Screw 7 Tables T...

Страница 2: ...n this document concerning performance of Evertz products are for informational use only and are not warranties of future performance either express or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features install...

Страница 3: ...in different versions to suit a variety of applications Throughout this manual references to 500FR refer to all models of the frame unless otherwise specified Model Description 500FR AC powered frame This frame supports all 500 series modules EXCEPT analog or digital loop through modules 500FR L A AC powered frame with loop thru capability for analog video signal This frame supports ONLY analog lo...

Страница 4: ...rminal relay N O N C for status fault alarm 2 A 125 VDC max Temperature 0 40 C 1 1 2 Physical Height 5 25 133 mm Width 19 483 mm Depth 9 5 368 mm Module Capacity 16 slots Weight Approx 17 lbs 7 7 Kg with 2 power supplies no slots occupied Approx 32 lbs 14 5 Kg with 2 power supplies all slots occupied 1 2 COOLING The 500FR frame is designed to ensure adequate cooling for up to 120 watts of processi...

Страница 5: ...atically senses the input voltage An additional power supply 500PS can be ordered to provide fully redundant powering of the frame When only one power supply is fitted the frame will be fitted with a 500PS FM fan module to ensure the thermal integrity of the frame cooling Power should be applied by connecting a 3 wire grounding type power supply cord to the power entry module on the rear panel of ...

Страница 6: ...e status buss fault conditions If one of the power supplies malfunctions power cord disconnected power switch is off fuse is blown rear fan is stopped etc then its PSU STATUS LED will go Off and the red FRAME STATUS LED on both power supplies will turn On If the power supplies are fitted with green FRAME STATUS LEDs they will turn Off The PSU STATUS LED on the power supply that is functioning will...

Страница 7: ...f the Frame Status Jumper on the module consult the individual chapter for the module For example if a module requires video or audio for its functionality and the video or audio is not present the red LOCAL FAULT LED on the module will be On and the fault will be reported on the frame status buss if the FRAME STATUS jumper on the module is set to the On position default 2 1 FRAME STATUS TALLY TER...

Страница 8: ... is located inside the power entry module To change the fuses pull out the fuse holder from the power entry module using a small screwdriver The fuse holder contains two fuses one for the line and one for the neutral side of the mains connection Pull out the blown fuse and place a fuse of the correct value in its place Use time delay 5 x 20 mm fuses rated for 250 Volts with a current rating of 4 a...

Страница 9: ...th only one power supply a 500PS FM blank power supply module with cooling fan must be inserted into the second power supply space The 500PS FM contains a module cooling fan and baffles to maintain proper airflow within the frame The power supply is secured into the frame by a machine screw through the rear panel as shown in Figure 2 This screw must be removed before the power supply can be extrac...

Страница 10: ...he power supply mounting screw 4 Open the front door of the frame and pull the power supply out of the frame 5 Reinsert the new power supply into the frame taking care that it is proper aligned with the card guides Press firmly to make sure that the power supply is fully seated into the rear panel connector 6 Reinstall the power supply mounting screw from the rear of the frame 7 Turn on the power ...