7700 MultiFrame Manual
7707VB-8-ASI-OC3 8 Channel ASI + Ethernet SONET / SDH Fiber Transceiver
Revision
1.0
Page - 27
6.3.
V
ISTA
LINK
®
CONTROLLED PARAMETERS
The following parameters can be remotely controlled through the
Vista
LINK
®
interface.
Parameter Description
Optical Standard
Allows user to set Optical Link Standard.
Laser
Allows the user to control the laser behavior when no video is present on coaxial
inputs. In Discontinuous mode the laser will be shut off with no valid input
signals. In Continuous mode the laser will continuously transmit and maintain the
link to the companion 7707VB-8-ASI-OC3.
Reference
Allows the user to select Oscillator, Link or Auto mode for clock settings.
Change Passcode
Setup the Passcode used to access the Video Blocking features.
Threshold
Allows the user to set Optical Level and Errored Seconds Threshold.
Video Block
Allows the user to enable/disable specific input or output video paths.
Output Mode
Allows the user to set output on loss to DISC or CONT mode.
Clear Counters
Allows the user to clear all error counters and reset the timer.
Table 6-2: VistaLINK
®