3.4.
GENERAL PURPOSE OUTPUTS
Number of Signals:
1 output
Connector at Breakout:
Multi-pin Removable Terminal Block
Output Type:
Dry contact relay closure to GPO ground, user selectable polarity (Normally
Open or Normally Closed), normally open (without power).
Output Current (min):
100mA
3.5. ELECTRICAL
Voltage:
+12VDC
Power:
8 Watts (Non DWDM)
11 Watts (DWDM)
EMI/RFI:
Complies with FCC Part 15, Class A
EU EMC Directive
3.6. COMPLIANCE
Electrical Safety:
CSA Listed to UL 60065-03, IEC 60065
Complies with CE Low voltage directive
Laser Safety:
Class 1 laser product
Complies with 24 CFR 1040.10 and 1040.11
IEC 60825-1
EMI/RFI:
Complies with FCC Part 15, Class A
EU EMC directive
3.7. PHYSICAL
7700 or 7701 frame mounting:
Number of slots: