7706LT
Extended L-Band RF Fiber Transmitter
Revision 1.1
Page - 21
6.1.17. Displaying the Laser Status
To display the laser status, select the
STAT
menu item in the first menu level, then use the toggle
switch to display the
LASR
option
and press the pushbutton to select it.
STAT
OK
Laser is operating normally.
OFF
Laser is disabled.
FALT
Fault in laser operation.
LASR
OK
OFF
FALT
6.1.18. Displaying the LNB Voltage Level
To display the LNB Voltage, select the
STAT
menu item in the first menu level, then use the toggle
switch to display the
LNBV
option
and press the pushbutton to select it.
STAT
Indicates the LNB output voltage.
LNBV
18V
13V
OFF
6.1.19. 22KHz Tone Status
To display the 22KHZ tone status, select the
STAT
menu item in the first menu level, then use the
toggle switch to display the
22KT
option
and press the pushbutton to select it.
STAT
Indicates whether the 22KHz tone on LNB output is enabled or
disabled.
ON
22KHz tone is enabled.
OFF
22KHz tone is disabled.
22KT
ON
OFF
6.1.20. Displaying the LNB Current
To display the LNB Current, select the
STAT
menu item in the first menu level, then use the toggle
switch to display the
LNBC
option
and press the pushbutton to select it.
STAT
Indicates the LNB current. Visible for -LNB versions only.
0 to 500mA
LNB current range.
LNBC
0 to 500mA
6.1.21. Displaying the LNB Current Threshold Level
To display the LNB Current threshold, select the
STAT
menu item in the first menu level, then use the
toggle switch to display the
LNTH
option
and press the pushbutton to select it.
STAT
LWR
Indicates the lower RF threshold level.
UPPR
Indicates the upper RF threshold level.
0 to 500mA
LNB current threshold range.
LNTH
LWR / UPPR
0 to 500mA