7700 MultiFrame Manual
7736CEM Composite Encoder with Monitoring
Revision 1.5
Page - 49
*Grey background indicates un-implemented or un-tested features
7.11.1. Setting Up How a Fault is Triggered and How it is Presented
The CEM has two fault conditions that can be configured to warn the user of numerous conditions. The
Fault condition
1
and
Fault condition 2
menu items are used to configure when fault 1 or fault 2 are
triggered, and how the fault should be presented. The controls for each fault condition operate the same
way so, for simplicity, the manual shows only the menu items for
Fault condition
1
.
7.11.1.1. Fault Status
Fault definitions
This menu item displays a screen that shows the current status of
all faults that can be used to define a fault condition
Fault condition 1
Fault status
7.11.1.2. Setting the position of the Fault Windows
Fault definitions
This control allows you to change the window positions of all
windows and bar graphs. The window positions can also be set
from the
Window position
menu item on the
On-screen display
configuration menu.
Fault condition 1
Window position
7.11.1.3. Setting the Message Associated with a Fault
Fault definitions
This control sets the message to display when the fault condition is
active. The text of the message can be changed. See section 7.2
for information on changing text fields.
Fault condition 1
Fault 1 message
Video error
7.11.1.4. Determining If the Fault Message Will Be Displayed
Fault definitions
This control sets whether the fault message will be displayed when
the fault condition is active.
When enabled, the fault message will be displayed until the
condition is reset. When disabled, it will never be displayed. See
section 7.11.1.5 for information on setting the duration of the fault
condition.
Fault condition 1
Fault 1 mode
Disable
Enable
7.11.1.5. Setting the Duration of the Fault Condition
Fault definitions
This control sets how long the fault condition will be held. The fault
display will be displayed as long as the fault condition is active and
the
Fault mode
is set to
Enable
. The fault condition can either be
held until the user clears the condition or until a programmable
timer expires.
Fault condition 1
Fault duration
Until reset
1 to 254 frames
30 frames