Evertree EBS201 Скачать руководство пользователя страница 8

DS Series Book Sterilizer 

Power 

 

WARNING 

 
-

DISCONNECTING THE DEVICE 
FROM THE MAIN POWER The 
Power plug is the disconnecting 
device. In case of an emergency, the 
Power Plug must remain readily 
accessible.  
 

-

The grounding wire should be 
connected. (Except for devices which 
are not grounded.) Ensure that you 
connect the grounding cable to avoid 
electric shock. If it is not possible to 
ground the unit, have a qualified 
electrician install a separate circuit 
breaker. Do not try to ground the 
Book Sterilizer by connecting it to 
telephone wires, lightning rods, or 
gas pipes.  
 

-

The power plug should be inserted 
fully into the power outlet. An 
unstable connection may cause a fire.  
 

-

Do not place heavy objects on the 
power cord. This may result in fire or 
electric shock.  
 

-

Never touch the power plug with wet 
hands. This may result in electric 
shock.  
 

-

Do not plug too many devices into 
one multi-power outlet. This may 
result in fire due to the power outlet 
overheating.  
 

-

Keep the AC adapter, power plug, 
and the used power outlet clean from 
dust or foreign materials building up. 
This may result in fire.  
 

 
 
 
 

-

If there is any smoke or a burning 
smell from the Book Sterilizer or AC 
adapter, stop using the product 
immediately. Disconnect the power 
cord from the power outlet, and then 
contact the customer service center. 
This may result in fire.  
 

-

To turn off the main power, remove 
the power plug, which should be 
positioned so it is easy to access for 
operation. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание EBS201

Страница 1: ...Before using this product carefully read all product documentation and retain it for future reference Read a book with Health EBS Series Book Sterilizer User Manual ...

Страница 2: ......

Страница 3: ... User s Manual Ⅱ The Necessity of Book Sterilization Ⅲ Sterilization Effect of Book Sterilizer Ⅳ Reference for Users Safety Ⅴ Structure of Book Sterilizer Ⅵ How to Operate Book Sterilizer After sale Service Regulation Product Warranty 4 5 6 7 10 12 ...

Страница 4: ...t warranty and the way to receive the after sale service Notes Some devices and data of the User s Manual cannot be provided or the contents such as the version modification depending on the circumstances of the parts manufacturer The images used in the User s Manual can be different form the actual product The explanation of use provided can be partially different depending on models LIVA EBS Ser...

Страница 5: ...ary Chemicals such as ammonia formaldehyde or xylene which is produced during book fabrication are well known as fatal material causing cancer Old books are the habitats for book worms It shorten book life time and results skin troubles for people 5 Ⅱ The Necessity of Book Sterilization The important harmful elements of the books in libraries and old books ...

Страница 6: ... Effect of Book Sterilizer Book dust formaldehyde xylene ammonia Dust Filter Book bugs virus bacteria molds and saliva spit snot and etc It sterilizes pathogen etic bacteria such as colon bacillus staphylococcus aureus vibrio salmonellas and etc by the short wavelength UV C 253 7mm that destroys DNA the source of bacteria lives UV Sterilization Filtering out dusts in books using the air internal c...

Страница 7: ...ht or near heat sources such as radiators fires stoves etc This may result in fire Do not place flammable materials such as aerosols near the Book Sterilizer This may result in fire Do not allow children to cling to or climb up to the Book Sterilizer This may cause the Book Sterilizer to fall causing injury or death Do not place the product close to sources of steam oil or oil mist such as humidif...

Страница 8: ... power outlet An unstable connection may cause a fire Do not place heavy objects on the power cord This may result in fire or electric shock Never touch the power plug with wet hands This may result in electric shock Do not plug too many devices into one multi power outlet This may result in fire due to the power outlet overheating Keep the AC adapter power plug and the used power outlet clean fro...

Страница 9: ...to the other side of the wall outlet while the power plug is inserted into the wall outlet In addition do not touch the power plug immediately after it is disconnected from the wall outlet This may result in electric shock Only use the official power cord provided by EVERTREE Do not use other power cords This may result in fire or electric shock If any water or foreign materials have gone into the...

Страница 10: ...ow the batteries when you replace the old remote control batteries with new ones Keep batteries out of reach of children If a child swallows a battery consult a doctor immediately Never open any cover on the Book Sterilizer to appliance while you are connected There is a high risk of electric shock Do not look directly into the lamps when the Book Sterilizer is in use The UV C light may damage you...

Страница 11: ...t spray the Book Sterilizer with water when cleaning Make sure water does not flow into the Book Sterilizer This may result in fire or electric shock When there is smoke or a strange smell coming out from the Book Sterilizer or a foreign object falls into the Book Sterilizer switch it off and unplug it from the power outlet and contact our service center Otherwise this may result in fire or electr...

Страница 12: ...f battery Burst or leaking batteries may result in damage or injury Make sure you use the same type of battery when replacing In the case of a battery contact failure the battery may drain quickly or the remote control may not work properly Dispose of used batteries properly This may result in explosion or fire The correct method of disposal may vary depending on your country or region Do not thro...

Страница 13: ...ls of convenient moving and stopper function 4 Book Sterilization Chamber It consists of 10 UV C ultraviolet lamps and 6 book fixation devices Ⅴ The Structure of Book Sterilizer EBS601_6 books type Dimension 700 x 590 x 1420mm Weight about 95kg Color Silver Tempered glass Sterilization method UV C ultraviolet lamp Number of lamp 10 ea Number of filter 3 ea Number of sterilized book 6 Sterilized co...

Страница 14: ...orth 6 Casters Wheels of convenient moving and stopper function 4 Book Sterilization Chamber It consists of 8 UV C ultraviolet lamps and 4 book fixation devices EBS401_4 books type Dimension 700 x 590 x 1420mm Weight about 90kg Color Silver Tempered glass Sterilization method UV C ultraviolet lamp Number of lamp 8 ea Number of filter 3 ea Number of sterilized book 4 Sterilized commodity Books and ...

Страница 15: ...wer 230V 50 60Hz SPECIFICATION 1 Status Display LCD Displaying the remaining time the sterilizer status and so forth 2 Start Button The button that starts sterilization 3 Tempered Glass Viewing Window The window through which the process of book sterilization can be seen 5 Machine Room Main electricity blowers filter and so forth 6 Casters Wheels of convenient moving and stopper function 4 Book St...

Страница 16: ... It may vary depending on the use conditions 2 Electrostatic Dust Filter It is located at the right and left walls 3 ea Replacement cycle 1 year 1 UV Lamp Quantity varies per model It is located in the book sterilization Chamber Replacement cycle after 30 000 on off Location and Replacement Cycle of Consumables 1 2 2 3 16 ...

Страница 17: ...Read a book with Health 17 1 2 1 2 UV Lamp 1 90º ...

Страница 18: ...DS Series Book Sterilizer Electrostatic Dust Filter Air Freshener UV Lamp 2 press 90º 18 ...

Страница 19: ... off when the door is opened during the book sterilization 19 Open the Sterilization room with the handle Split the book and hold with both hand Fix the book on the open state Close the Sterilization room Press the start button in the upper right Take out the books and close the door after sterilization ...

Страница 20: ...Series Book Sterilizer 2 System Setting Setting Button It is located at the front ceiling inside the sterilization chamber Consisting of 4 buttons MENU SELECT UP DOWN POWER ON OFF Display LCD 1 2 3 4 5 20 ...

Страница 21: ...lizer setting and is usually deactivated 2 Displaying Current State It displays the current state of the book sterilizer WAITING Standby state OPEN The sterilization room door is opened CLOSED The sterilization room door is closed STERILIZATION Under sterilization DONE Sterilization is completed 3 Displaying Remaining Time Counting each one second from the set sterilization time and displaying the...

Страница 22: ... MENU No 1 SET TIMER SELECT UP DOWN Time adjustment SELECT It is basically set as 60 seconds recommended and the sterilization time can be set by 10 seconds unit 2 Checking Use Number NUMBER OF USE Press MENU No 2 NUMBER OF USE Checking the number used till now 22 ...

Страница 23: ...amp Replacement Notice Time Setting SET LAMP TIME Press MENU No 4 SET LAMP TIME SELECT UP DOWN Time adjustment SELECT 30000 on off recommendation is basically set and it is available to set by 100 hours unit If the use time exceeds the lamp replacement setting time the lamp replacement icon at the left bottom blinks 23 ...

Страница 24: ...Sterilizer 5 Use Time Initialization TIME RESET Press MENU No 5 TIME RESET Press SELECT for 3 seconds Initializing Use Time and Use Number When the lamp replacement icon blinks initialize it after lamp replacement 24 ...

Страница 25: ...Read a book with Health BOOK STERILIZER 25 ...

Страница 26: ...after sale service engineer s visit repair and do not perform the repair by courier or carry service We are not responsible for customers books Free repair period of consumables is 3 months from the purchase date of the product With regard to the flaws caused by natural disasters or unstable voltage at the use location free repair is not available We are not responsible for the flaw caused by the ...

Страница 27: ...Read a book with Health 88 48 Saneop ro 156beon gil Gwonseon gu Suwon si Gyenggi do Korea 27 ...

Страница 28: ...BOOK STERILIZER TEL 82 31 302 8500 88 48 Saneop ro 156beon gil Gwonseon gu Suwon si Gyenggi do Korea zipcode 16648 www evertree kr ...