Group 2 commands:
When the detector is triggered, the unit will send BASIC_SET command which contains a value to
the nodes of Group 2.
Z-Wave Plus Info
Role Type
Node Type
Installer Icon
User Icon
Slave Sleeping report
Z-Wave Plus node
Sensor Notification
Device Type (Home
Security)
Sensor Notification
Device Type (Home
Security)
Version
Protocol Library
3 (Slave_Enhance_232_Library)
Protocol Version
4.3D ( 6.71.01)
Manufacturer
Manufacturer ID
Product Type
Product ID
0x0060 0x0001 0x0006
AGI (Association Group Information) Table
Group
Profile
Command Class & Command (List) N bytes
Group Name(UTF-8)
1 General
Battery Report
Notification Report
Device Reset Locally Notification
Lifeline
2
Control
Basic Set
PIR Control
Notification
Event
Type
Event
Event
Parameters
Length
Event Parameters
The power is applied for the first time
0x08
0x01
0x00
PIR Trigger ON
0x07
0x08
0x00
PIR Trigger OFF
0x07
0x00
0x01
0x08
Tamper switch being press more than 10
seconds
0x07 0x00 0x01
0x03
Tamper switch being press more than 10
seconds and released
0x07 0x03 0x01
Battery
Battery Report (value)
Description
20
~
100 Battery Level (%)
0xFF Low
Battery
Command Classes
The module supports Command Classes including…
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
*
COMMAND_CLASS_ASSOCIATION_GRP_INFO
*
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V2
*
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
*
COMMAND_CLASS_DEVICE_RESET_LOCALLY
*
COMMAND_CLASS_POWERLEVEL
*
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
*
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
*
COMMAND_CLASS_BATTERY
*
COMMAND_CLASS_WAKE_UP_V2
*
COMMAND_CLASS_NOTIFICATION_V4
*
COMMAND_CLASS_CONFIGURATION
*
*Items marked an asterisk are secure command classes.
Wakeup Command Class
After it has been included into a Z-Wave network, the detector will go to sleep but will send a Wakeup
Notification Command periodically at preset period to the controller. The Motion detector will stay awake
for 10 seconds at least and then go back to sleep to conserve battery life.
The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class
based on the range values below:
Minimum Wake Up Interval
600s (10 minutes)
Maximum Wake Up Interval
86400s (1 day)
Default Wake Up Interval
14400s (4 hours)
Wake Up Interval Step Seconds
600s (10 minutes)
Z-Wave’s Configuration
The following information is for someone that has some experience in setting up a Z-Wave system or
someone that has computer software running a Z-Wave controller. Please get familiar with software of
Z-Wave controller before getting started.
To save power consumption for the battery, RF power of SP817 is in off mode ordinarily. Pls press
Tamper switch once to on the RF power for 30 sec. in order to start function set up, and the user can see
the LED start lighting up shortly every sec.. If set up is not finished within 30 sec., please press Tamper
switch one more time to continue the set up.
1-1 Basic Set Level
When Basic Set Command is sent where contains a value, the receiver will take it for
consideration; for instance, if a lamp module is received the Basic Set command of which value is
decisive as to how bright of dim level of lamp module shall be.
Example:
1-99: ON
(Binary Switch Device)
Dim Level (Multilevel Switch Device)
Function
Parameter Number
Size
Range Default
Basic Set level
1
1
1 ~99
99
1.
Sensitivity Level (PIR sensor only)
In order to provide a best efficiency of the detector, it is recommended to test the detector with
movements from a farthest end of the coverage area at first time of use. If movements cannot be
detected sensitively, simply adjust the sensitivity level with Configuration Parameter #3. This
parameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10
means highest sensitivity.
Function
Parameter Number
Size
Range Default
Sensitivity Level
3
1
1~10
6
2.
Re-trigger Interval Setting (PIR sensor only)
The Configuration parameter that can be used to adjust the interval of being re-triggered after the
detector has been triggered as Configuration Parameter #4. No response will be made during
this interval if a movement is presented. The time interval can be set between 5 secs to 3600
secs.
Function
Parameter Number
Size
Range Default
Re-trigger Interval
4
2
5~3600(sec) 180