2.
Fix the rear cover to the wall using the supplied screws and wall plugs. Do not over-tighten the fixing
screws as this may distort or damage the cover.
3.
Replace the main body to the rear cover and refit the fixing screw in the bottom of the PIR to secure
the main body. Do not over-tighten the fixing screw as this may damage the casing.
Operation
When the detector is mounted on the wall i.e. tamper switch is pressed for more than 10 seconds, it will
enter Normal mode.
- Upon motion being detected, the detector will send an alert signal to the controller and enter
sleep state for a preset period to conserve battery life. It will only be able to detect motion again
when this preset period is up. This preset period is called Retrigger Interval and can be set by the
controller. The default period is 3 minutes.
- Unlike in Test mode, the red indicator LED on the detector will not illuminate when triggered in
order to conserve battery life.
The detector can provide periodic auto report measurement of temperature and humidity to the
controller, or on demand when requested by the controller.
In the event its front cover is removed, the tamper switch will be activated and the detector will send a
Notification command to the controller.
Maintenance
Low Battery: Under low battery condition, the detector will remit RF signals to the Z-Wave controller to
alert the user of its low battery condition. Replace the batteries as soon as possible.
Programming
Z-Wave Group
The PIR detector supports 2 Association Groups:
Group 1
: Association with 1 Controller node.
Group 1 command:
When the unit is powered up or the tamper is triggered, the unit will send a Notification Report to
the node of Group 1.
When the battery level of the unit drops to an unacceptable level, the unit will emit Battery report to
the nodes of Group 1.
When performing Factory Reset the unit will send Device Reset Locally Notification to the node of
Group1.
The unit will send Multilevel Sensor Report to the node of Group 1.
Group 2
: Association with 4 nodes (i.e. end devices such as smart plugs and other lighting controllers).
This allows the detector to transfer commands directly to end devices without the participation of the
controller. This has the effect that when the detector triggers, all devices associated with detector will be
operated.
Group 2 commands:
When the detector is triggered, the unit will send BASIC_SET ON/OFF command which contains
a value to the nodes of Group 2.
Z-Wave Plus Info
Role Type
Node Type
Installer Icon
User Icon
Slave Sleeping
Listening
Z-Wave Plus node
Sensor Notification
Device Type (Home
Security)
Sensor Notification
Device Type (Home
Security)
Association Command Class
Group
Max Node
1
1
2
4
Version
Protocol Library
3 (Slave_Enhance_232_Library)
Protocol Version
4.3D ( 6.71.01)
Manufacturer
Manufacturer ID
Product Type
Product ID
0x0060
0x0001
0x0004
AGI (Association Group Information) Table
Group
Profile
Command Class & Command (List) N bytes
Group Name(UTF-8)
1
General
Battery Report,
Device Reset Locally Notification,
Notification Report
Lifeline
2
Control
Basic Set
PIR Control
Notification
Event
Type
Event
Event
Parameter
Length
Event
Parameter
The power is applied for the first time
0x08
0x01
0x00
PIR Trigger ON
0x07
0x08
0x00
PIR Trigger OFF
0x07
0x00
0x01
0x08
Tamper switch being press more than 10
seconds
0x07
0x00
0x01
0x03