2

4.  Prepare one 9V alkaline battery. Do not insert it into the unit yet. 

5.  Log into the Homesys account from a web browser. 

6.  Select “System”, then “Add a Device”, 

 

7.  Select “Smoke Detector”. 

 

 

 

 

 

 

 

 

 

 

 

 

8.  The following screen will appear. This means the gateway is entering binding 

mode.  

 

 

 

 

 

 

 

 

9.  Insert the batteries with correct polarity at this point. 

10. Plug the connector 

 back to connector pins 

 of the sensor module. Make 

sure its direction is correctly inserted according to the sticker affixed on the 

sensor.

 

 

 
 
 
 
 

 

11. The screen below will appear in 10 seconds if the process is successful. 

 

 

 

 

 

 

 

 

 

 

 

12. Time-out will occur if the binding process was unsuccessful. Please refer to 

the “Manual Binding” procedure. 

 

 

Manual Binding 
 

1.  Repeat steps 4 to 8 of the Binding with Homesys section. 

 

2.  With the battery inserted and connector

 connected to sensor module, 

press and hold the Learning key

 for 3 seconds then release, and the Link 

LED 

10

 will start to flash. This implies SF804-0 has now entered binding 

mode. 

 

3.  Within 5 seconds, the Link LED will stop flashing and then turn off, indicating 

Содержание SF804-0

Страница 1: ...sists of two parts a sensor module and a transmitter module The transmitter module can be detached by twisting it clockwise against the sensor module Sensor Module Front and Back view Transmitter module Front and Back view Binding with Homesys 1 Twist the transmitter module clockwise to detach it from the sensor module 2 Disconnect the connector from the connector pins of the sensor module Take no...

Страница 2: ...rrectly inserted according to the sticker affixed on the sensor 11 The screen below will appear in 10 seconds if the process is successful 12 Time out will occur if the binding process was unsuccessful Please refer to the Manual Binding procedure Manual Binding 1 Repeat steps 4 to 8 of the Binding with Homesys section 2 With the battery inserted and connector connected to sensor module press and h...

Страница 3: ... unit Minimum coverage is one detector on each floor and one in each sleeping area 1 Remove the mounting bracket from the detector by rotating it counterclockwise 2 Use a 5mm drill bit to drill two holes and insert the provided plastic wall plugs 3 Use the two screws and provided plastic wall plugs to attach the bracket to the wall 4 Line up the slot of the bracket and the detector Push the detect...

Страница 4: ...ging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Страница 5: ...mitter must not be co located or operating in conjunction with any other antenna or transmitter 2 This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body www everspring com 3F No 50 Sec 1 Zhonghua Rd Tucheng Dist New Taipei Cit...

Отзывы: