EVERSPRING SE814 Скачать руководство пользователя страница 3

 

Association Command Class 

 

Group 

Max Node 

 

Version 

Protocol Library 

3 (Slave_Enhance_232_Library) 

Protocol Version 

4.3D ( 6.71.01) 

 

Manufacturer 

Manufacturer ID 

Product Type 

Product ID 

0x0060 

0x000C 

0x0002 

 

AGI (Association Group Information) Table 

Group 

Profile 

Command Class & Command (List) N bytes 

Group Name(UTF-8) 

General 

Battery Report, 
Device Reset Locally Notification, 
Notification Report 

Lifeline 

 

Notification 

Event 

Type 

Event 

Event 
Parameters 
Length 

Event Parameters 

The power is applied for the first time   

0x08 

0x01 

 

 

Shutdown occur (voltage below 5.5V) 

0x09 

0x07 

 

 

Shutdown clear (voltage over 5.95V) 

0x09 

0x00 

0x01 

0x07 

Tamper switch is pressed  more than 3 
seconds 

0x07 

0x00 

0x01 

0x03 

Tamper switch is  pressed  more than 3 
seconds and released 

0x07 

0x03 

 

 

 
Battery 

Battery Report (value) 

Description 

20~100 

Battery Level % 

0xFF 

Low Battery 

 
Switch Binary 

Report/Control (value) 

Description 

0x00 

Siren Off 

0xFF 

Siren On 

 
Configuration: 

Siren alarm period

 

Parameter Number 

Size 

Range 

Default 

10~600 

180 seconds 

 
Command Classes 

The module supports Command Classes including… 

  COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

  COMMAND_CLASS_ASSOCIATION_V2

*

 

  COMMAND_CLASS_ASSOCIATION_GRP_INFO

*

 

  COMMAND_CLASS_TRANSPORT_SERVICE_V2 

  COMMAND_CLASS_VERSION_V2

*

 

  COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2

*

 

  COMMAND_CLASS_DEVICE_RESET_LOCALLY

*

 

  COMMAND_CLASS_POWERLEVEL

*

 

  COMMAND_CLASS_SECURITY   

  COMMAND_CLASS_SECURITY_2 

  COMMAND_CLASS_SUPERVISION

*

 

  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

*

 

  COMMAND_CLASS_BATTERY 

*

 

  COMMAND_CLASS_NOTIFICATION_V4

*

 

  COMMAND_CLASS_SWITCH_BINARY

*

 

  COMMAND_CLASS_CONFIGURATION

*

 

 

*Items marked an asterisk are secure command classes.

 

 
Troubleshooting 
 

The table below lists the several steps involved when adding or removing the detector from the Z-Wave 
network.

 

 

Action/Status 

Description 

LED indication 

No node ID 

The Z-Wave Controller does not allocate a 
node ID to the unit. 

2-second on, 2-second off 
For 2 minutes 

Auto Inclusion 

The power is applied for the first time and no 
node ID has been stored in the module, or after 
executing reset. 

 

Manual Inclusion 

Refer to the Manual Inclusion section below. 

 

Exclusion 

1. Put the Z-Wave Controller into exclusion 

mode. 

 

2. Press the tamper switch 3 times within 1.5 

seconds to put the unit into exclusion mode. 

Factory Reset 
(This procedure 
should only be used 
when the controller is 
inoperable.) 

1. Press the tamper switch 3 times within 1.5 

seconds to put the unit into exclusion mode. 

 

2. Within 1 second of step 1, press the tamper 

switch again and hold for 5 seconds. 

 

3. Node ID is excluded. The device reverts to 

factory default state. 

2-second on, 2-second off 
For 2 minutes 

 Failed or successful results in including/excluding the ID can be viewed on the Z-Wave Controller. 

 
Manual Inclusion 

1. 

Locate the Control Box area and remove its waterproof cover by unscrewing it. Identify the Link 
button inside. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Control 
Box 
C

 

Link Button 

Содержание SE814

Страница 1: ...he unit indoors in order to set up its Z Wave connection and to perform preliminary tests Auto Inclusion The siren supports Auto Inclusion feature where it will automatically enter Inclusion mode when first powered up after a factory reset 1 Open up the siren by removing the fixing screw from the bottom edge and carefully peeling off the back cover All electronic components are housed within the f...

Страница 2: ... screw on the back cover tamper plunger to ensure the switch closes when the siren is secured in position Note removing the main unit from its back plate will cause the Tamper alarm to sound Quickly disarm the alarm panel if this happens 8 Upon completion of mounting the main body on the wall the Strobe LED will flash about 3 seconds as an indication of normal operation Operation 1 Alarm Activatio...

Страница 3: ...POWERLEVEL COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_CONFIGURATION Items marked an asterisk are secure command classes Troubleshooting The table below lists the several steps involved when adding or removing the detector from the Z Wave n...

Страница 4: ...off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes o...

Отзывы: