Association Command Class
Group
Max Node
1
1
Version
Protocol Library
3 (Slave_Enhance_232_Library)
Protocol Version
4.3D ( 6.71.01)
Manufacturer
Manufacturer ID
Product Type
Product ID
0x0060
0x000C
0x0002
AGI (Association Group Information) Table
Group
Profile
Command Class & Command (List) N bytes
Group Name(UTF-8)
1
General
Battery Report,
Device Reset Locally Notification,
Notification Report
Lifeline
Notification
Event
Type
Event
Event
Parameters
Length
Event Parameters
The power is applied for the first time
0x08
0x01
Shutdown occur (voltage below 5.5V)
0x09
0x07
Shutdown clear (voltage over 5.95V)
0x09
0x00
0x01
0x07
Tamper switch is pressed more than 3
seconds
0x07
0x00
0x01
0x03
Tamper switch is pressed more than 3
seconds and released
0x07
0x03
Battery
Battery Report (value)
Description
20~100
Battery Level %
0xFF
Low Battery
Switch Binary
Report/Control (value)
Description
0x00
Siren Off
0xFF
Siren On
Configuration:
Siren alarm period
Parameter Number
Size
Range
Default
1
2
10~600
180 seconds
Command Classes
The module supports Command Classes including…
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
*
COMMAND_CLASS_ASSOCIATION_GRP_INFO
*
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V2
*
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
*
COMMAND_CLASS_DEVICE_RESET_LOCALLY
*
COMMAND_CLASS_POWERLEVEL
*
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
*
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
*
COMMAND_CLASS_BATTERY
*
COMMAND_CLASS_NOTIFICATION_V4
*
COMMAND_CLASS_SWITCH_BINARY
*
COMMAND_CLASS_CONFIGURATION
*
*Items marked an asterisk are secure command classes.
Troubleshooting
The table below lists the several steps involved when adding or removing the detector from the Z-Wave
network.
Action/Status
Description
LED indication
No node ID
The Z-Wave Controller does not allocate a
node ID to the unit.
2-second on, 2-second off
For 2 minutes
Auto Inclusion
The power is applied for the first time and no
node ID has been stored in the module, or after
executing reset.
Manual Inclusion
Refer to the Manual Inclusion section below.
Exclusion
1. Put the Z-Wave Controller into exclusion
mode.
2. Press the tamper switch 3 times within 1.5
seconds to put the unit into exclusion mode.
Factory Reset
(This procedure
should only be used
when the controller is
inoperable.)
1. Press the tamper switch 3 times within 1.5
seconds to put the unit into exclusion mode.
2. Within 1 second of step 1, press the tamper
switch again and hold for 5 seconds.
3. Node ID is excluded. The device reverts to
factory default state.
2-second on, 2-second off
For 2 minutes
Failed or successful results in including/excluding the ID can be viewed on the Z-Wave Controller.
Manual Inclusion
1.
Locate the Control Box area and remove its waterproof cover by unscrewing it. Identify the Link
button inside.
Control
Box
C
Link Button