background image

Содержание SE812

Страница 1: ...riggered Z Wave enabled devices refer to nodes in the system also act as repeaters so as to re transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots The Indoor Siren integrates both functions of siren and strobe into one unit Two sound levels 100dB and 90dB are available for selection When it receives a ...

Страница 2: ...ult The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z Wave MCertificated Primary Controller to access the setup function and to include exclude associate devices Function Description LED Beep Indication No node ID The Z Wave Controller does not allocate a node ID to the Siren LED 2 second on 2 second off Beep 0 1 second on 9 9 second o...

Страница 3: ...oller Installation The Siren is suitable for mounting in dry interior locations only Please follow these directions when first setting up or for the purpose of battery replacing 1 Undo and remove the fixing screws from the bottom edge of the Indoor Siren and remove the rear cover FIGURE 1 2 2 Insert four LR14 1 5V size alkaline batteries to the battery compartment ensuring correct polarity is put ...

Страница 4: ...RE 6 4 Slide the unit down to the rear cover and lock the screw clockwise FIGURE 7 f v FIGURE 6 FIGURE 7 Operation Two jumper links are disposed insidethe Siren Two Phase Sound Jumper Link and Tamper Jumper Link FIGURE 8 You can enable or disable the jumper linkby fitting iton or removing it FIGURE 9 Tamper Switch Jumper Links FIGURE 8 t t Jumper LinkFitted Jumper LinkRemoved FIGURE 9 ...

Страница 5: ...rouping 1 For Grouping 1 the Siren will emit reports including POWER_APPLIED Tamper Trigger Report and Battery LowBattery Report 1 1 POWER_APPLIED command When power is applied it will send ALARM_REPORT command to nodes of Grouping 1 to inform the devices that the Siren is powered up ALARM_REPORT Command Command Class Alarm Alarm Report Type 0x02 Level 0x011 1 2 Tamper Trigger Report When tamper s...

Страница 6: ...ff Command Class Basic Basic Set Value 255 0xFF the Siren generates a full alarm condition by flashing strobe light and sounding alarm for 3 minutes Command Class Basic Basic Set Value 0 0x00 the Siren stops full alarm condition Command Class Switch Binary Switch Binary Set Value 255 0xFF the Siren generates a full alarm condition by flashing strobe light and sounding alarm for 3 minutes Command C...

Страница 7: ...TCH_BINARY COMMAND_CLASS_VERSION COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_MANUFACTURER_SPECIFIC Troubleshooting Symptom Possible Cause Recommendation LED cannot be displayed or Siren not working 1 Run out of battery power 2 Check if reverse battery polarity 1 Replace a new battery 2 Refit the battery with correct polarity The Siren is out of order Don t open the Siren send ...

Страница 8: ...ent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Caution Any ch...