4
Manual Binding
1.
Locate the Control Box area and remove its waterproof cover by
unscrewing it.
Identify the Link button inside.
2.
With the 9V battery still connected, repeat steps 5 to 6 of the Binding with
Homesys section.
3.
Press and hold the Link Button for more than 4 seconds until the Strobe LED
starts to flash rapidly then release.
4.
Within 5 seconds the Strobe LED will stop flashing and turn off, indicating the
binding procedure is completed. The screen below will appear to confirm this.
Reset to Factory Settings
1.
Press and hold the Link Button for more than 4 seconds until the Strobe LED
starts to flash rapidly then release.
2.
Press and hold the Link button again for more than 6 seconds until the Strobe
LED turns off, then release. The LED will flash every 2 seconds indicating the
siren is now reset back to factory mode factory.
Jumper Settings
The siren preset settings can be modified by adjusting the jumper settings inside its
Control Box.
1.
Locate the Control Box area and remove its waterproof cover by unscrewing it.
2.
Identify the set of jumper links JP1. The settings for each is described below:
Position
Jumper fitted
Jumper removed
ALARM
Alarm sound enabled
Alarm sound disabled
CU
Must be fitted
N/A , factory use only
1MIN
1 minute alarm sound
3 minute alarm sound
ANTI
Anti-jamming enabled
Anti-jamming disabled
BEEP
Beep sound enabled
Beep sound disabled
JP1
Beep
A.J.
1 MIN
C.U.
Alarm
JP1 Settings
Control
Box
Cover
Link Button