background image

HSM02 

DOOR/WINDOW DETECTOR 

 
The Door/Window Detector is a Z-Wave

TM

 enabled device and is fully compatible 

with any Z-Wave

TM

 enabled network. Z-Wave

TM

 enabled devices displaying the 

Z-Wave

TM

 logo can also be used with it regardless of the manufacturer, and ours 

can also be used in other manufacturer’s Z-Wave

TM

 enabled networks.  Inclusion 

of this Door/Window Detector on other manufacturer’s Wireless Controller menu 
allows remote turn-on of connected modules and their connected lighting when the 
Detector is triggered. 

LED

TEMPER
SWITCH

BATTERY

BATTERY

MYLAR

FIXED
SCREW

 

 

Include to or Exclude from a Z-Wave

TM

 Network   

 
In the front casing, there is a tamper switch which is used to carry out inclusion, 
exclusion or reset.  When power is first applied, its LED flashes on and off 
alternately and repeatedly at 2-second intervals.  It implies that it has not been 
assigned a node ID and cannot work with Z-Wave enabled devices.    Please get 
familiar with the terms below before starting the operations.     

 

Function

 

Description

 

Inclusion 

 

Add a Z-Wave enabled device (e.g. Detector) to Z-Wave network.

 

Exclusion 

 

Delete a Z-Wave enabled device (e.g. Detector) from the network.

 

Association 

 

After inclusion, you have to define the relationship between devices. 
Trough association, device can be assigned as master/slave, and specify 
which slave is going to be controlled by which master.

 

Reset

 

Restore Detector to factory default.

 

 
The table below lists an operation summary of basic Z-Wave functions.  Please 
refer to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access 

the setup function, and to include/exclude/associate devices.   

 

Function Description 

LED 

Indication 

No node ID 

The Z-Wave Controller does not allocate 
a node ID to the unit. 

2-second on, 2-second 
off 

Inclusion 

1.  Have Z-Wave Controller entered 

inclusion mode. 

 

2.    Pressing tamper switch three times 

within 1.5 second will enter inclusion 
mode. 

Exclusion 

1.  Have Z-Wave Controller entered 

exclusion mode. 

LED lights up once 
whenever tamper switch 
is pressed once. 

2.  Pressing tamper switch three times 

within 1.5 second will enter 
exclusion mode. 

Reset 

1.  Press tamper switch three times 

within 1.5 second. 

 

2.  Within 1 second, press and hold the 

tamper switch until LED is off. 

LED keeps on before 
reset function has been 
completed. 

3.  IDs are excluded and all of preset 

value will be reset to factory default.

2-second on, 2-second 
off 

Association 

1.    Have Z-Wave Controller entered 

association mode. 

 

2.    When pressing tamper switch three 

times within 1.5 second, the unit will 
emit the NIF which implies that the 
unit has entered association mode. 

 

Ú

Including a node ID allocated by Z-Wave Controller means inclusion.    Excluding a node 
ID allocated by Z-Wave Controller means exclusion. 

Ú

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller.

 
 

Содержание HSM02

Страница 1: ...ich slave is going to be controlled by which master Reset Restore Detector to factory default The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM Certificated Primary Controller to access the setup function and to include exclude associate devices Function Description LED Indication No node ID The Z Wave Controller does not alloca...

Страница 2: ...inting towards and aligned with the line on the detector An alarm condition will be occurred if the gap is greater than 35mm 5 Remove the battery cover with the tamper switch not being pressed on the detector test mode detach or close the magnet from the Detector the LED on the detector will illuminate 6 After proper installation and test put the battery cover back to the detector and the detector...

Страница 3: ...1 2 Low Battery Report When HSM02 automatically wakes up it will check the battery usage When low battery is detected Alarm Report Command will be sent to Nodes in Grouping 1 afterward LED will light up for 1 sec to remind user when HSM02 is triggered due to open or close incidents 1 3 Tamper Event Report Alarm Report Press and hold the tamper switch more than 10 seconds then release the unit will...

Страница 4: ... Programming The following information is for someone that has some experience setting up a Z Wave system or someone that has computer software running a Z Wave controller 3 1 Battery Check Command The users can also enquire the battery status of the unit by sending BATTERY_GET command via Z Wave Controller Once the unit receives the command it will return BATTERY_REPORT command The unit will send...

Страница 5: ...ng Does not fit batteries or run out of battery power Check if batteries are fitted or replace with new batteries Break down Send it for repair and do not open up the unit Specifications Battery CR2450 3 0V 620mAh Lithium Battery x 2 Range 30m line of sight Frequency Range 908 42 MHz US 868 42 MHz EU Specifications are subject to change without notice A501111906R01 2013 05 WARNING Do not dispose o...

Страница 6: ...reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experie...