- 2 -
When the unit is powered for the first time, the unit will send a Notification Report to the node of Group 1.
When setting the unit or changing the unit’s status, the unit will send a Binary Switch Report to the node
of Group 1.
When performing Reset the unit will send Device Reset Locally Notification to the node of Group1.
The unit can be configured to periodically report the value of W and/or kW*h to the node of Group 1
(refer to Configuration parameter 4 & 5). The interval time between two reports is at least 30 seconds.
The unit can be configured to report the status of wattage to the node of Group 1 on special occasions
(refer to Configuration parameter 6 & 7).
The minimum interval time between two reports sent from this unit to the node of Group 1 is 3 seconds.
Refer to
Configuration
parameter 2 for more information.
When the button on the unit or the wall switch is pressed, the unit will send a Basic Set command to the
nodes of Group 2. When the unit is OFF, Basic Set Value = 0x00. When the unit is ON, Basic Set
Value = 0xFF.
Z-Wave Plus Info
Role Type
Node Type
Installer Icon
User Icon
Slave Always On
Z-Wave Plus node
On/Off Power Switch
On/Off Power Switch
Version
Protocol Library
3 (Slave_Enhance_232_Library)
Protocol Version
3.95 ( 6.51.02)
Firmware 0 Version
1V0
Hardware Version
2
Firmware 1 Version
1V0
Manufacturer
Manufacturer ID
Product Type
Product ID
0x0060
0x0004
0x0006
AGI (Association Group Information) Table
Group
Profile
Command Class & Command (List) N bytes
Group Name(UTF-8)
1
General:NA
Binary Switch Report,
Notification Report,
Device Reset Locally Notification,
Meter Report
Lifeline
2
Control:Key1
Basic Set
On/Off control (Button1)
Basic
Basic Get: Inquire about the status of the device.
Basic Report: Report the status of the device.
Basic Set: Set the status of the device.
Notification
When powered on, the device will send (Notification Type = 0x08, Event = 0x01) to the node of Group 1.
When overload occurs, the device will send (Notification Type = 0x08, Event = 0x08) to the node of Group 1.
Configuration
The configurable values are as following:
Parameter
Number
Parameter Function
Size
Range
Default
1
Set Basic Set Command value 2
0~99, 255(0xFF)
255 (0xFF)
2
Set the delaying time to report
to Group 1
1
3 - 25 (seconds)
3
3
Set whether to remember the
last status
1
1/0
1: remember
(0: do not remember)
4
Set the interval for wattage auto
report
2
0-32767 (minutes)
1
(0: does not report
automatically)
5
Set the interval for kW*h auto
report
2
0-32767 (minutes)
60
(0: does not report
automatically)
6
Auto report when load
surpasses the set value of
wattage
2
0-2500 (W)
0
(0: does not report
automatically)
7
Auto report when the change of
wattage surpasses the set
percentage
1
0-100 (%)
0
(0: does not report
automatically)
Meter
Supports kW*h, W, V, A, and PF:
Meter Type
Scale
Size
Precision
Electric Meter
kW*h
4
2
W
4
2
V
2
2
A
2
2
PF
1
2
Command Classes
The module supports Command Classes including…
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_APPLICATION_STATUS_V1
Additional Command Classes Supported
Power Level: For test purpose during product installation.
Binary Switch: Refer to Basic.
Switch All: The device turns on when receiving “Switch All On”, and turns off upon receiving “Switch All
Off”.
Firmware Update: For OTA function.
Troubleshooting
Symptom
Cause of Failure
Recommendation
Device not responding and
The device is not connected to the
Check if connection is correct,