
- 2 -
Manufacturer
Manufacturer ID
Product Type
Product ID
0x0060
0x0004
0x0007
AGI (Association Group Information) Table
Group
Profile
Command Class & Command (List) N bytes
Group Name(UTF-8)
1
General:NA
Binary Switch Report,
Notification Report,
Device Reset Locally Notification
Lifeline
2
Control:Key1
Basic Set
On/Off control (Button1)
Basic
Basic Get: Inquire about the status of the device.
Basic Report: Report the status of the device.
Basic Set: Set the status of the device.
Notification
The device will send notifications (Notification Type =0x08, Event = 0x01) upon being powered on.
Configuration
The configurable values are as following:
Basic Set Command value:
Parameter Number
Size
Range
Default
1
2
0~99 , 255(0xFF)
255 (0xFF)
The delaying time to report to Group 1:
Parameter Number
Size
Range
Default
2
1
3 - 25 (seconds)
3
Remember the last status:
Parameter Number
Size
Range
Default
3
1
1/0
1: remember
(0: do not remember)
Command Classes
The module supports Command Classes including…
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Additional Command Classes Supported
Power Level: For test purpose during product installation.
Binary Switch: Refer to Basic.
Switch All: The device turns on when receiving “Switch All On”, and turns off upon receiving “Switch All
Off”.
Firmware Update: For OTA function.
Troubleshooting
Symptom
Cause of Failure
Recommendation
Device not responding and
LED not displaying
The device is not connected to the
mains power correctly
Check if connection is correct,
or voltage is too high or too low
Device malfunction
Send the device to be repaired
LED displaying, but cannot
control On/Off status of
connected load
The connected load has its own
on/off switch
Turn the switch of the
connected load to On.
Can press button to control,
but cannot control by RF
RF interference is occurring.
Someone nearby might be emitting
RF signal of the same frequency
Wait for a while and retry the
operation
Specification
Power Input
220-240V/50Hz
Maximum Load
Resistive load Max.1500W, Incandescent load Max. 800W, Fluorescent load
Max.200W
Transmission Range
30 meters (Indoor; Open space)
Working Temperature
-10°C - 40°C
*Specifications are subject to change without notice
2013/07
Warning:
Do not dispose of electrical appliances as unsorted municipal waste; use separate collection facilities.
Contact your local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance
for disposal at least for free of charge.