Clearing the ID Code
1. Make sure the Module is in Off status (LED lights off). If not, press the
On/Off/Dim button to turn off the Module. Keep pressing the button until the
LED flashes rapidly. A 30-second countdown will start.
2. Press the button again more than 6 seconds within 30-second countdown, the
preset ID code will be cleared.
Note:
LED turns back to flashing status if ID code is cleared.
Operation
2
z
Toggle the On/Off/Dim button for On or Off. Turn on the button of which LED
will be on and the incandescent lamp controlled by AD132-1 will be on, while
pressing the button again will turn off the incandescent lamp and its LED will
be off.
z
To adjust brightness/dimness level, press
the On/Off/Dim button on the module to
turn on the lighting device. The default
setting of brightness is 50% (refer to the
asterisk as shown in Fig 2). Press and
hold the On/Off/Dim button to start
brightness adjustment. The brightness
level will go up, and when it goes up to the
maximum value (100%), it will start
adjusting dimness. Choose the ideal level
you desire and release the On/Off/Dim
button simultaneously. The brightness/
dimness level is now fixed as you wish.
Please note there are two outcomes for dimmer adjustment. As you know,
press and hold the On/Off/Dim button to start light level adjustment as
prerequisite. The key point is to keep your finger off the button before
pressing and holding the button. For instance, for
brightness
level
adjustment, if you release the button before pressing the button again, it will
switch to dimness adjustment automatically. On the contrary, for
dimness
level adjustment, if you release the button before pressing the button again, it
will shift to brightness adjustment automatically.
z
When setting to On, the Module will initiate wattage detection function. Upon
detecting overload condition, the Module will be switched to Off, the
On/Off/Dim button will be disabled and the LED will flash rapidly for 30
seconds. Reset the Module by unplugging and re-connecting the plug to the
electrical outlet.
Troubleshooting
Symptom
Cause of Failure
Recommendation
The Module not working and
LED off
1. The Module is not
connected to the mains
properly
2. The Module is out of
order
1. Check if wire connection
is correct
2. Don’t open up the Module
and send it for repair
The Module’s LED working,
but cannot control the
ON/OFF switch of the
incandescent lamp connected
to the Module
Check if the switch of
incandescent lamp
connected to the Module
is set in OFF
Set the On/Off switch of the
connected incandescent lamp
to ON
The Module’s LED working,
but the Transmitter not
working
1. Incorrect ID code
2. Same frequency
interference
1. Learning the ID code again
2. Wait for a while to re-try
Specification
*
50%
BRIGHTNESS
Operating Voltage
120V/60Hz
Maximum Load
300W, for incandescent lamps only
Minimum Load
25W, for incandescent lamps only
Range
Up to 100 meter line of sight
Frequency Range
923.00 MHz
100%
0%
** Specifications are subject to change and improvement without notice.
Compatibility
DIMNESS
50%
Fig. 2
The following transceivers (sold separately) can control THIS module:
923.00MHz
Transmitter USB Dongle Flood Detector IR Beam Detector Temperature & Illumination
Humidity Detector Sensor
(AC124) (SA804) (ST802) (ST803) (ST804) (ST805)
IMPORTANT! To avoid poor compatibility with devices of other brands, purchase
only Everspring UNet devices to ensure best compatibility is strongly
recommended.