Clearing the ID Code 
 

1.  Make sure the Module is in Off status (LED lights off).  If not, press the 

On/Off/Dim button to turn off the Module.    Keep pressing the button until the 
LED flashes rapidly.    A 30-second countdown will start. 

 
2.  Press the button again more than 6 seconds within 30-second countdown, the 

preset ID code will be cleared. 

 

Note:

 LED turns back to flashing status if ID code is cleared.   

 

Operation 

 

z

 

Toggle the On/Off/Dim button for On or Off. Turn on the button of which LED 
will be on and the incandescent lamp controlled by AD132-1 will be on, while 
pressing the button again will turn off the incandescent lamp and its LED will 
be off. 

 
 

z

 

To adjust brightness/dimness level, press 
the On/Off/Dim button on the module to 
turn on the lighting device.  The default 
setting of brightness is 50% (refer to the 
asterisk as shown in Fig 2).  Press and 
hold the On/Off/Dim button to start 
brightness adjustment. The brightness 
level will go up, and when it goes up to the 
maximum value (100%), it will start 
adjusting dimness.    Choose the ideal level 
you desire and release the On/Off/Dim 
button simultaneously.  The brightness/ 
dimness level is now fixed as you wish.   

 

Please note there are two outcomes for dimmer adjustment. As you know, 
press and hold the On/Off/Dim button to start light level adjustment as 
prerequisite. The key point is to keep your finger off the button before 
pressing and holding the button.  For instance, for 

brightness

 level 

adjustment, if you release the button before pressing the button again, it will 
switch to dimness adjustment automatically.  On the contrary, for 

dimness

 

level adjustment, if you release the button before pressing the button again, it 
will shift to brightness adjustment automatically. 
 

z

 

When setting to On, the Module will initiate wattage detection function. Upon 
detecting overload condition, the Module will be switched to Off, the 
On/Off/Dim button will be disabled and the LED will flash rapidly for 30 

seconds. Reset the Module by unplugging and re-connecting the plug to the 
electrical outlet. 

 
Troubleshooting 
 

Symptom 

Cause of Failure 

Recommendation 

The Module not working and 
LED off 

1.  The Module is not 

connected to the mains 
properly 

2.  The Module is out of 

order 

1.  Check if wire connection 

is correct 

2. Don’t open up the Module 

and send it for repair 

The Module’s LED working, 
but cannot control the 
ON/OFF switch of the 
incandescent lamp connected 
to the Module 

Check if the switch of 
incandescent lamp 
connected to the Module   
is set in OFF 

Set the On/Off switch of the 
connected incandescent lamp 
to ON 

The Module’s LED working, 
but the Transmitter not 
working 

1.  Incorrect ID code 
2. Same frequency 

interference  

1. Learning the ID code again 
2. Wait for a while to re-try 

 
Specification 
 

*

50%

BRIGHTNESS

Operating Voltage 

120V/60Hz 

Maximum Load 

300W, for incandescent lamps only 

Minimum Load 

25W, for incandescent lamps only 

Range 

Up to 100 meter line of sight 

Frequency Range 

923.00 MHz 

 

100% 

0% 

** Specifications are subject to change and improvement without notice.

     

 
Compatibility 
 

DIMNESS

50%

Fig. 2

The following transceivers (sold separately) can control THIS module: 
923.00MHz 

     

           

             

               

     

Transmitter   USB Dongle  Flood Detector  IR Beam Detector   Temperature &     Illumination 

                                                                                                                      Humidity Detector        Sensor         

 (AC124)      (SA804)      (ST802)         (ST803)           (ST804)          (ST805)     

IMPORTANT! To avoid poor compatibility with devices of other brands, purchase 
only Everspring UNet devices to ensure best compatibility is strongly 
recommended.

 