Installation

1.  It is recommended that a professional sign company be hired to install the scoreboard.  SEE 

DRAWINGS

2.  Eversan recommends a minimum depth of 5 ft. and a 2ft. footer diameter.

3.  Calculate the wind loading by standard formula for height and dimension of sign.

     

  NOTE:

 Check local codes for your area.

4.  Prepare and sink I-beams, W6 x 15 I-Beam conforming to ASTM A36 recommended minimum, 

align with plumb line and careful measurements.

5.  Determine height of lowest point for scoreboard.  Mark and align on all mounting beams parallel to 

visual ground sighting.

6.  Drill and bolt (3/8 hardened bolts) or weld provided bottom Z-brackets to the posts as shown in the 

installation diagram.

7.  Lift scoreboard set onto Z bracket. Secure temporarily with a clamp.

8.  Place the top Z-brackets on the board and install in the same manner as the lower.

9.  The board is now ready to be wired.

Instructions for Wiring

1.  Determine 120VAC entrance and run conduit to pre-installed electric box on back of scoreboard. 

See diagram.

2.  The scoreboard draws under 6 amp but requires its own circuit breaker.  Eversan, Inc. 

recommends using a 10 amp, GFCI breaker.

CAUTION: Cabled Version Only

The data cable is a pre-wired, 1 pair twisted shielded. Any cable splicing should be color-

coded or failure of the computer power supply will result. Continuity of the shield is essential in 

reducing possible damage due to lightening.

Electrical Specifications:

 

Electric outlets for scoreboards are always on a “clean” unused, switched breaker box. Pay 

close attention to the power source and connections. It is recommended that a key-switch or 

switched breaker box be used to turn off the system at the end of use each day, turning off the 

Control Console does not power down the scoreboard. 

The scoreboard should always be 

powered down when not in use.

Power up Sequence

120VAC Operation

1.  Plug the control console into the scoreboard using the cable provided. Any of the 2-pin 

connectors on the control console can be used. The connector for the scoreboard is located 

on the back. (Cabled System only)(see Diagram)

2.  Power up the scoreboard using 120VAC,connection on back of scoreboard. (see Diagram)