background image

©2007 Pentair Water Treatment 

340016   AU07

VALVE

(SUPPLIED BY

INSTALLER)

FLANGE AND 

GASKET

(SUPPLIED BY INSTALLER)

BYPASS HEADER ASSEMBLY 

(MUST BE VERTICALLY 

MOUNTED)

HOSE

CLAMPS

FLEXIBLE

TUBING

WATER METER

FEEDER 

ASSEMBLY

VALVE

(SUPPLIED BY

INSTALLER)

BYPASS HEADER 

AND VALVE

(SUPPLIED BY

INSTALLER)

DUAL FEED

VALVE

ASSEMBLY

ALLOW 13 INCHES MIN.

FROM TOP OF FEEDER

TO OVERHEAD FOR

REMOVAL OF CARTRIDGE 

14-1/2" PLUS 

THICKNESS

OF GASKET

23" MAX

18" MAX

LOW         HIGH

EVERPURE

®

  

BROMINATOR

Model SSFm-50

Type II, Class 1

  NICN-4610

  Serial No.

  Job No.

Plymouth Products

Sheboygan, Wisconisn 53081

SIZING AND ORDERING A 

PROPORTIONING BROMINATOR

For each distiller / watermaker served, determine the capacity 
in gallons per day. Using this figure, calculate the discharge in       
gallons per minute. For example: 12,000 gpd /24, /60 = 8.3 gpm.  
Choose a part number corresponding to these flow rates:

SSFM-50AC SERIES 

BROMINATOR 

FLOW RATE (gpm)

SSFM-50AC SERIES 

BROMINATOR 

PART NO.

REPLACES

PART NO.

0.7

169096

EV906410

0.8 – 1.2

169097

EV906411

1.3 – 1.4

169098

EV906412

1.5 – 1.8

169099

EV906413

1.9 – 3.0

169100

EV906414

3.1 – 4.0

169101

EV906415

4.1 – 8.3

169102

EV906416

NOTES

A potable water storage tank should be treated whenever it is  
filled from a shore source, or whenever there is no measurable 
bromine residual in the tank. A measurable bromine residual will 
insure the water is safe to drink. See our recirculating brominator 
data sheets for this application.

SPECIFICATIONS

Weight

SSFM-50AC:     35 lbs. (15.9 kg)

Dry Weight

SSFM-50AC:     30 lbs. (13.6 kg)

MOuNTING

System components should be vertically mounted on a  
bulkhead or stanchion within reasonable proximity to each 
other and the bypass header assembly. A minimum of 13 
inches of overhead clearance is required above the feeder  
assembly for easy removal of the disposable bromine  
cartridge. For convenience, the instruction plate with  
operating procedure should be bulkhead mounted adjacent  
to the proportioning bromine feeder.

PLuMBING TERMINATIONS

The proportioning bromine feeder is flanged per MIL-F-20042, 
3/4-inch for all SSFM-50AC series models. A three valve by-
pass loop should be plumbed into bypass the proportioning  
bromine feeder during maintenance or bromine cartridge 
change. This bypass loop can be provided by the installer.

Pentair Filtration, Inc.

502 Indiana Avenue - P.O. Box 1047

Sheboygan, Wisconsin 53082-1047 

Phone 866.873.7506    Fax 888.203.7361

International Phone 920.457.9435   International Fax 920.457.2417

www.everpure.com

Отзывы: