5
CHAPTER 6
Understanding the Control
Operation
Cleaning and Maintenance
Actual Temperature F or C
Power Button
Manual Defrost Switch
Optional Light Switch
Raise Temperature
Set Temperature
Lower Temperature
Cooling Indicator
Fan on Indicator
Connect the plug to the proper outlet. If it is not the correct outlet, the outlet must be replaced with the
correct one by a qualified electrician, as well as ensuring the fuse or breaker is the correct current capacity for
the draw of the appliance. Do not use adapters, multiple outlets and/or extension cords. Do not plug in
multiple appliances in the same outlet that may exceed current capacity.
Use mild cleaning products, such as dish detergent or Pine Sol to clen the unit. Do not use any scouring pads
or nylon scrubbers, as this will scratch the surface. Do not flood the compartment with water or use a hose or
pressure washer to clean the interior or exterior of the unit, as extreme damage will occur. The use of a
stainless steel cleaner and polish can be used on the exterior only.
Ensure the door gaskets are kept clean and if they are ripped or damaged, they must be replaced to maintain
proper operation.
1. Turn the unit on by pushing the control on by pushing and holdin the power switch for 2 seconds.
2. To set the cabinet temperature, press the
set
switch and then using the up or down buttons until the
desired setting is reached, push the
set
button again.
3. The compressor has a 1 minute delay before it comes on.
4. Once the evaporator coil has reached 40 degrees, the fan(s) will be activated and the cabinet will begin
to cool.
5. Allow the cabinet to pre-cool for at least 1 hour before loading in product. If the product is at ambient
temperature, the cabinet temperature will rise and it may take a couple of hours to stabilize.
6. Once the temperature inside the cabinet reaches the set temperature, the cooling indicator light will
go out, but the fans will continue to run. When the temperature rises, the cooling indicator will turn
back on and the compressor will activate to bring the temperature back down to the set point.
7. Do not keep the door(s) open for an extended period of time, as this will cause the temperature to rise
rapidly and product will not maintain temperature.
8. To turn the unit off, push and hold the power switch for 2 seconds.