background image

HYDRAULIC KIT

 

 

 

 

 

 

39

 

Содержание 1000/BL1

Страница 1: ......

Страница 2: ...dren We live in times with great ecological problems Planet Earth is sounding the alarm of ecological danger The thoughtless use of mineral energy sources is resulting in increased pollution of the at...

Страница 3: ...ipheral accessories Basic Accessories Page 23 Peripheral accessories Optional Accessories Page 24 Solar Systems Forced circulation systems Models Page 25 Typical installation diagrams Page 26 Installa...

Страница 4: ...the sun radiation of each area and the size of the system Simple The well studied selection of materials of Everhot make Its Installation safe and easy reducing the time needed for Its Installation to...

Страница 5: ...e protected during their Transport with 4 plastic elbows of hard plastic 3 Cardboard box with all of the accessories except pipes and wires which are required for the installation of the system like h...

Страница 6: ...g machine and the dishwasher we would have to increase the calculated daily needs of consumption as follows Washing Machine 20 liters day 1 wash per day Dishwasher 20 liters day 1 wash per day Example...

Страница 7: ...ser The information of the above table can also be used in combinations so that in every case the average daily consumption can be properly calculated In the case that a recirculation system exists fo...

Страница 8: ...ntral heating boiler in the case where the above mentioned circumstances do not exist the storage tank can heat up from secondary source of energy for example central heating boiler This occurs throug...

Страница 9: ...ool and 40mm rock wool minimize Thermal losses in areas with low seasonal temperatures Special prismatic glass resistant to hale solar tempered glass Absorber made from one unique sheet absorber with...

Страница 10: ...Back insulation 35 40 mm insulation Side insulation 20 mm glass wool Cover Material solar tempered glass Thickness 4mm Water tightness joint EPDM and transparent silicone Total thermal efficiency 95...

Страница 11: ...45 C and 40 C For every day of the month the efficiency of the collector is calculated where the maximum efficiency and the heat losses of the collector are taken into account depending on the existi...

Страница 12: ...CLIMATIC DATA OF SELECTED WORLD CITIES 12...

Страница 13: ...Energyoutputofthecollectorinseveralcitiesoftheworld inkWh m2 13...

Страница 14: ...IES OF THE WORLD in KWh m2 in temperature 40 C Collector ST 2000 selective Base of results Test of DEMOKRITOS GREECE Collector ST 2000 selective Base of results Test of DEMOKRITOS GREECE Collector ST...

Страница 15: ...f each installation Example For one system 300 E BL1 with 3 collectors ST 2000 in a parallel connection total surface area 6 30m2 we can choose a medium flow rate of 60lt h per square meter of install...

Страница 16: ...ectric resistance 2 9 KW Available with one or two tube heat exchangers suitable for every Application Upon a special order buffers can be delivered 150lt 1000lt models BL0 without a tube heat exchang...

Страница 17: ...namel Food grade enamel quality applied with a double direct method and baked at 850 C BUFFER tanks are excluded Extra corrosion protection is offered by magnesium rods that must be checked and replac...

Страница 18: ...940 350 675 900 1150 315 567 850 982 Thermal losses Kwh 24H 2 24 2 68 model Bl 500 Bl 800 Heat Exchangers Solar lower Heat Exchanger Bl1 models Back up Heat Exchanger Bl2 models Solar lower Heat Excha...

Страница 19: ...it Rugged design Cost effective installation and filling Multi functional ball valve which greatly simplifies the filling and draining of the system Collector and reservoir sections can be separated f...

Страница 20: ...ions If the handle is pointing in the direction of flow the system medium can circulate An integrated check valve stops osite direction and also acts as a gravity brake right closes the ball cock in t...

Страница 21: ...am Vent pipe Painted steel Valve housing components Brass Internal components Stainless steel brass and plastic Sight glass Boric silicate O ring seals EPDM Flat seals with high temperature resist anc...

Страница 22: ...perature difference controller for the various system variants Depiction of graphics and texts in a lighted display Simple viewing of the current measurement values Analysis and monitoring of the syst...

Страница 23: ...If the total length of the closed circuit is over 100 m with a 22mm pipe then it is recommended to use a bigger expansion vessel the general rule for choosing an expansion vessel is 10 of the total v...

Страница 24: ...at 6 or 9 kW 3 400 V without thermostat Thermostat All of the single phase electric resistances up to 4 kW are delivered with a thermostat with a uni polar interruption function as well as a bi polar...

Страница 25: ...150 1 2 61 150 BL1 M 150 1 2 10 200 BL1 200 2 2 x 2 10 200 BL1 M 200 1 2 61 300 BL1 300 2 2 x 2 61 300E BL1 300 3 3 x 2 10 300 BL1 M 300 2 2 x 2 10 420 BL1 420 3 3 x 2 10 420E BL1 420 3 3 x 2 61 500 B...

Страница 26: ...s You must always consult a specialized engineer for your own installation 1 Solar collectors 2 Storage tank boiler 3 Hydraulic kit 4 Expansion vessel 5 Differential Thermostat 6 Circulator for recirc...

Страница 27: ...ll this alternate equipment always under the concurrent opinion of the customer 8 For installation on an inclined roof the D plates must be screwed with the appropriate screws and nuts on the roof tim...

Страница 28: ...ers or on the concrete of the roof D 1180 mm D 1220 mm For support bases with 1 2 collectors For support bases with 3 collectors Screw tightly the rectangular frame A C or E onto the plates D Level th...

Страница 29: ...Installation Instructions Support base for 1 collector ST 2000 or ST 2500 p 30 31 Support base for 2 collectors ST 2000 or ST 2500 p 32 33 Support base for 3 collectors ST 2000 or ST 2500 p 34 35 29...

Страница 30: ...Assembly diagram of the support base for one 30...

Страница 31: ...collectorST2500onaflatorinclinedsurface attention the plate a is connected to the plate B exactly as shown in the detailed 31...

Страница 32: ...Assemply diagram of the support base for two attention for the installation of two collectors on a tiled roof the plates C are installed in the middle hole of the plates a 32...

Страница 33: ...collectors ST 2500 on a flat or inclined surface attention the plate a is con nected to the plate B exactly as shown in the detailed diagram 33...

Страница 34: ...Assembly diagram of the support base for three 34...

Страница 35: ...Collectors ST 2500 on a flat or inclined surface Attention In the installation of the support base with three collectors on a tiled roof the three plates C are not used 35...

Страница 36: ...ed to the outlet on the highest point of the collector s as shown in the photo In order to achieve the best contact between the the sensor and the sensor socket use thermal conductive material before...

Страница 37: ...Connectionofcollectorsandaccessories 37...

Страница 38: ...pump from the hydraulic kit The functioning pressure between 1 5 and 3 bar can be achieved with the pressure pump or the pressure of the water supply We constantly check all of the points of degassing...

Страница 39: ...HYDRAULIC KIT 39...

Страница 40: ...installation of the unit The technical characteristics can change without prior notification If your Solar Collector will be stagnant in the sun for an extended period of time you should cover the co...

Страница 41: ...system Antifreeze liquid must be disposed of correctly 5 Open the check valve 6 Slowly open the drain tap When the initial low created by pressure has stopped open the air vent at the top of the sola...

Страница 42: ...stallation of the system should be per formed only by authorized installer Collectors shouldbecoveredduringinstallation forexam plewiththesamecoverusedfortransportation The collectors will be filled w...

Страница 43: ...lling with pump YES NO Electric characteristics adjustment of differential thermostat Model of Differential Thermostat Adjustment of maximum temperature for the protection of the boiler C Adjustment o...

Страница 44: ...the leaking of liquid or thermal fluid water Is there a safety valve connected Is there an indication of the make and type of thermal liquid on a label installed in a viewable area DIFFERENTIAL THERM...

Страница 45: ...SPECIAL QUALITY INSPECTION IDENTIFICATION BADGE that certifies IT S QUALITY IT S PERFORMANCE IT S DESIGN 46 1 Conference room 2 Design of products moulds 3 Automatic welding machine of the storage ta...

Страница 46: ...systems throughout the world contributing to the ecological protection of the environment on a daily basis Some of the countries where mEGaSUN is successfully exported Germany Italy France Spain Cana...

Отзывы: