![EverFocus PARAGON960 X4 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/everfocus/paragon960-x4/paragon960-x4_user-manual_2443298024.webp)
PARAGON960 X4
16
2.3.3
Alarm I / O
The DVR provides 16 alarm inputs and 4 alarm outputs. Please refer to the table below for PIN
assignment.
Alarm in
Alarm out
Figure 2-16
Alarm Input
No.
Description
1-16
ALM_IN1 – ALM_IN16
G
GND
Alarm Input Contacts
This DVR provides one alarm input per camera. All inputs are programmable N.O. (Normal
Open) or N.C. (Normal Closed). All settings are programmed in the ALARM / Event menu.
ALMIN
GND
ALMIN
GND
Alarm Input with N.O. contact in idle state
Alarm Input with N.C. contact in idle state
Alarm Output Contacts
The relay output provides either Normally Open or Normally Closed dry contacts.
ALMOUT -
ALMOUT -